CD45‐assisted Pan Leuco gating for accurate, cost‐effective dual‐platform CD4+ T‐cell enumeration
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
BACKGROUND: North American and European guidelines for dual‐platform (DP) flow cytometry recommend absolute CD4 T‐cell counts to be calculated from two parameters: the absolute lymphocyte counts obtained on a hematology analyzer and the percentages of CD4+ cells among lymphocytes (CD4%/lympho) obtained by flow cytometry. Nevertheless, the identification of lymphocytes is error‐prone: a poor match between these common denominators in the two systems is the main source of inaccuracy. In contrast, total leucocyte counts (white cell counts [WCC]) and CD4% among the gated CD45+ leucocytes (CD4%/leuco) can be determined with greater accuracy. Methods: We introduced “Pan Leuco gating,” i.e., we used total leucocytes as the common denominator for improving the precision of DP absolute CD4 counting. Correlations and Bland‐Altman tests were used for statistical analysis. Results: First, 22 stabilized blood product samples were provided by U.K. National External Quality Assessment Scheme (NEQAS) and a higher accuracy and precision of CD4 counts were documented using Pan Leuco gating compared with lymphocyte gating. Next, 183 fresh and 112 fixed (TransFix) whole blood samples were used to compare DP methods and single‐platform (SP) methodology, including both volumetric and bead‐based techniques. A particularly high correlation and comparable precision of absolute CD4 counts were observed between the SP volumetric method and DP Pan Leuco gating (R 2 = 0.990; bias 6 ± SD 17%). The SP volumetric method showed lower levels of agreement with the DP lymphocyte gating (R 2 = 0.758; bias 14 ± SD 51%) and with the SP bead‐based method (R 2 = 0.923; bias 4 ±SD 31%). Conclusions: These observations show that DP leucocyte counts (WCC) should replace lymphocyte counts as the “common denominator” although CD4%/lympho values can, as an extra step, be also provided readily if requested. When coupled with quality control for WCC on hematology analyzers, the DP method with CD45 Pan Leuco gating represents a robust CD4 T‐cell assay that is as accurate as the SP volumetric technique. This DP method uses only two, CD45 and CD4, antibody reagents and can be run on any pair of hematological analyzer plus flow cytometer. Cytometry (Clin. Cytometry) 50:69–77, 2002. © 2002 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Cited by
Redman, K. N., Karstaedt, A. S., & Scheuermaier, K. (2018) · Brain, Behavior, and Immunity · doi:10.1016/j.bbi.2018.02.002 · Cited by 62
Premature ageing of the immune system underlies immunodeficiency in ataxia telangiectasia
Exley, A. R., Buckenham, S., Hodges, E., Hallam, R., Byrd, P., Last, J., Trinder, C., Harris, S., Screaton, N., Williams, A. P., et al. (2011) · Clinical Immunology · doi:10.1016/j.clim.2011.03.007 · Cited by 30
Flow Rate Calibration for Absolute Cell Counting Rationale and Design
Walker, C., & Barnett, D. (2006) · Current Protocols in Cytometry · doi:10.1002/0471142956.cy0624s36 · Cited by 5
“Therefore, the need to obtain accurate, reliable (and affordable) absolute leukocyte counts (Janossy et al., 2000; Glencross et al., 2002; Mandy et al., 2002) has resulted in the development of “single-platform” technology whereby manufacturers have produced instruments and techniques that have the…”
BackgroundMethodSelf-citation
Metadata
- Authors
- Glencross, D., Scott, L. E., Jani, I. V., Barnett, D., & Janossy, G.
- Venue
- Cytometry
- Publisher
- Wiley
- Published
- 2002-04-15
- Volume
- 50
- Issue
- 2
- Pages
- 69-77
- ISSN
- 0196-4763 (ISSN-L)
- 1097-0320
- OpenAlex
- W2069198171
- Cited by
- 158
- References
- 1
- FWCI
- 5.14
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.