CoChat

Flow cytometric quantitative determination of ingestion by phagocytes needs the distinguishing of overlapping populations of binding and ingesting cells

Open access
Nuutila, Jari, Lilius, Esa‐Matti · 2005 · Cytometry Part A
Cited by 128

The DOI matches its Crossref record.

Abstract

Background: The use of flow cytometry with fluorescently labeled particles provides the means to examine quantitatively the phagocytotic capacity of an individual phagocyte. This report describes an improved flow cytometric method of analysis for kinetic measurement of phagocytosis of fluorescein isothiocyanate (FITC)–labeled zymosan particles by human leukocytes. Methods: FITC‐labeled zymosan was incubated with leukocyte suspension, and at selected time intervals fluorescence positive neutrophils were divided by phagocytotic gates into three subpopulations: neutrophils that were neither binding nor ingesting particles, neutrophils that were only binding particles (binding cells), and neutrophils that were binding and ingesting particles (ingesting cells). For the distinction between internalized and surface‐bound FITC‐labeled zymosan, trypan blue (1.2 mg/ml) was used to quench surface‐bound fluorescence. Results: The technical challenges related to settings of phagocytotic gates and derivation of phagocytotic equations were presented. From 28 control samples, numerical values of mean fluorescence intensities and percentages of phagocytotic subpopulations inside phagocytotic gates before and after quenching were inserted into phagocytotic equations and corrected phagocytotic parameters were calculated. Calculated parameters were surprisingly constant across individuals. Conclusions: Essential elements of the present method appeared to be partial quenching of extracellular fluorescence with trypan blue and distinguishing between overlapping populations of binding and ingesting cells. Corrections using derived phagocytotic equations proved necessary for accurate kinetic phagocytotic measurements. Corrections were less necessary when the ingestion process was finished. © 2005 Wiley‐Liss, Inc.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/cyto.a.20139

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 128

Metadata

Authors
Nuutila, J., & Lilius, E.
Venue
Cytometry Part A
Publisher
Wiley
Published
2005-05-10
Volume
65A
Issue
2
Pages
93-102
ISSN
  • 1552-4922 (ISSN-L)
  • 1552-4930
OpenAlex
W1992062692
Cited by
128
References
0
FWCI
1.61
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Flow cytometric quantitative determination of ingestion by phagocytes needs the distinguishing of overlapping populations of binding and ingesting cells. https://app.cochat.ai/papers/10.1002/cyto.a.20139
The paper
Nuutila, J., & Lilius, E. (2005). Flow cytometric quantitative determination of ingestion by phagocytes needs the distinguishing of overlapping populations of binding and ingesting cells. Cytometry Part A. https://doi.org/10.1002/cyto.a.20139

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.