CoChat

A novel method based on click chemistry, which overcomes limitations of cell cycle analysis by classical determination of BrdU incorporation, allowing multiplex antibody staining

Cappella, Paolo, Gasparri, Fabio, Pulici, Maurizio, Moll, Jürgen · 2008 · Cytometry Part A
Cited by 106

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

Quantification of BrdU incorporation into DNA is a widely used technique to assess the cell cycle status of cells. DNA denaturation is required for BrdU detection with the drawback that most protein epitopes are destroyed and classical antibody staining techniques for multiplex analysis are not possible. To address this issue we have developed a novel method that overcomes the DNA denaturation step but still allows detection of BrdU. Cells were pulsed for a short time by 5‐ethynyl‐2′‐deoxyuridine, which is incorporated into DNA. The exposed nucleotide alkyne group of DNA was then derivatized in physiologic conditions by the copper (I)‐catalyzed azide‐alkyne cycloaddition (CuAAC) using BrdU azides. The resulting DNA‐bound bromouracil moiety was subsequently detected by commercial anti‐BrdU mAb without the need for a denaturation step. Continuous labeling with EdU showed a slightly increased anti‐proliferative activity compared to BrdU. However, using a lower concentration of EdU for labeling can compensate for this. Alkynyl tags could be detected quickly by a highly specific reaction using BrdU azides. Fluorescence quenching by the DNA dye PI using both BrdU azides was negligible. Our labeling method is suitable for FCM and HCA and shows a higher signal to noise ratio than other methods. This method also allowed multiplex analysis by simultaneous detection of EdU‐BrdU, caspase‐3, and phospho‐histone 3 mAbs, proving sensitivity and feasibility of this new technique. In addition, it has the potential for use in vivo, as exemplified for bone marrow studies. We have established a new method to determine the position of cells in the cell cycle. This is superior when compared to traditional BrdU detection since it allows multiplex analysis, is more sensitive and shows less quenching with PI. The method provides new opportunities to investigate changes in protein expression at different cell cycle stages using pulse labeling experiments. © 2008 International Society for Advancement of Cytometry

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/cyto.a.20582

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 106

Metadata

Authors
Cappella, P., Gasparri, F., Pulici, M., & Moll, J.
Venue
Cytometry Part A
Publisher
Wiley
Published
2008-06-02
Volume
73A
Issue
7
Pages
626-636
ISSN
  • 1552-4922 (ISSN-L)
  • 1552-4930
OpenAlex
W2052072871
Cited by
106
References
3
FWCI
4.62
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.