Background: Multiplex bead array assays permit simultaneous cytometric quantitation of multiple cytokines in solution by capturing these to spectrally distinct beads. Because several manufacturers offer reagents to quantitate the same cytokines on a single instrument, a comparison should be made to determine whether these kits yield similar data and whether these data are comparable to enzyme‐linked immunosorbent assay (ELISA). Methods: This study compared cytokine detection kits by using Luminex 100. Twenty‐six serum samples from seven subjects were analyzed for interferon‐γ, interleukins 1β, 6, and 8, and tumor necrosis factor‐α by using multiplex kits from LINCO Research, Bio‐Rad Laboratories, R&D Systems, and BioSource International. Each assay was performed according to the manufacturers' specifications. Standard curves were generated by using reference concentrations supplied by each manufacturer. ELISAs for interleukin‐8 were performed by using kits from R&D and BioSource. Results: Cytokine levels followed similar patterns, although absolute concentrations differed among kits. ELISA and Luminex values for interleukin‐8 were similar in kits from the same manufacturer. Conclusions: Because relative cytokine measurements are often valuable when performed serially, it may be possible to make interlaboratory comparisons by using different kits. When comparison of absolute values is crucial, kits from the same supplier should be used. Within‐vendor, bead array, and ELISA values appear comparable. Published 2004 Wiley‐Liss, Inc.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/cyto.b.20021

Cites

11 of 11 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 11 references

Cited by

See all 354

Metadata

Authors
Khan, S. S., Smith, M. S., Reda, D., Suffredini, A. F., & McCoy, J. P.
Venue
Cytometry Part B: Clinical Cytometry
Publisher
Wiley
Published
2004-08-03
Volume
61B
Issue
1
Pages
35-39
ISSN
  • 1552-4949 (ISSN-L)
  • 1552-4957
OpenAlex
W1968827381
Cited by
354
References
11
FWCI
8.31
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Multiplex bead array assays for detection of soluble cytokines: Comparisons of sensitivity and quantitative values among kits from multiple manufacturers. https://app.cochat.ai/papers/10.1002/cyto.b.20021
The paper
Khan, S. S., Smith, M. S., Reda, D., Suffredini, A. F., & McCoy, J. P. (2004). Multiplex bead array assays for detection of soluble cytokines: Comparisons of sensitivity and quantitative values among kits from multiple manufacturers. Cytometry Part B: Clinical Cytometry. https://doi.org/10.1002/cyto.b.20021

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.