Diabetes management in the new millennium using insulin pump therapy
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
Current goals of therapy of type 1 and 2 diabetes are to achieve near normal glycemia, minimize the risk of severe hypoglycemia, limit excessive weight gain, improve quality of life and delay or prevent late vascular complications. As discussed in this review, insulin pump or continuous subcutaneous insulin infusion (CSII) therapy provides a treatment option that can dramatically aid in achieving all of these goals. In comparison to multiple daily injections (MDI), CSII uses only rapid-acting insulin, provides greater flexibility in timing of meals and snacks, has programmable basal rates to optimize overnight glycemic control, can reduce the risk of exercise-induced hypoglycemia, and enhances patients' ability to control their own diabetes. Most important, in adults and adolescents with type 1 diabetes, CSII has been shown to lower HbA(1c) levels, reduce the frequency of severe hypoglycemia and limit excessive weight gain versus MDI without increasing the risk of diabetic ketoacidosis. Similarly positive results are being seen with CSII in adults with type 2 diabetes. The effectiveness of CSII and improvements in pump technology have fueled a dramatic increase in the use of this therapy. Practical guidelines are presented for selection of patients, initiation of treatment, patient education, follow-up assessments and troubleshooting. The recent introduction of methods for continuous glucose monitoring provides a new means to optimize the basal and bolus capabilities of CSII and offers the hope of the development of a feedback-controlled artificial pancreas.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Purnell, J. Q., Hokanson, J. E., Marcovina, S. M., Steffes, M. W., Cleary, P. A., & Brunzell, J. D. (1998) · JAMA · doi:10.1001/jama.280.2.140 · Cited by 469
Binder, C., Lauritzen, T., Faber, O., & Pramming, S. (1984) · Diabetes Care · doi:10.2337/diacare.7.2.188 · Cited by 341
Bode, B. W., Steed, R. D., & Davidson, P. C. (1996) · Diabetes Care · doi:10.2337/diacare.19.4.324 · Cited by 257
Self-citationBode, B. W., Gross, T. M., Thornton, K. R., & Mastrototaro, J. J. (1999) · Diabetes Research and Clinical Practice · doi:10.1016/s0168-8227(99)00113-8 · Cited by 232 · cited 1×
“If the HbA1c is still not at goal, the patient is then placed on a MiniMed continuous glucose monitoring system (CGMS) which monitors glucose levels continuously for up to 72 h in order to determine reasons for suboptimal control [32].”
Self-citation
Cited by
(2007) · Endocrine Practice · doi:10.4158/ep.13.s1.1 · Cited by 699
Outpatient Insulin Therapy in Type 1 and Type 2 Diabetes Mellitus: Scientific Review
DeWitt, D. E., & Hirsch, I. B. (2003) · JAMA · doi:10.1001/jama.289.17.2254 · Cited by 502
Use of Insulin Pump Therapy in the Pediatric Age-Group
Phillip, M., Battelino, T., Rodriguez, H., Danne, T., Kaufman, F., & participants, F. T. C. F. (2007) · Diabetes Care · doi:10.2337/dc07-9922 · Cited by 316
Tanenbaum, M. L., Hanes, S. J., Miller, K. M., Naranjo, D., Bensen, R., & Hood, K. K. (2017) · Diabetes Care · doi:10.2337/dc16-1536 · Cited by 296
Microinfusion Using Hollow Microneedles
Martanto, W., Moore, J. S., Kashlan, O., Kamath, R., Wang, P. M., O'Neal, J. M., & Prausnitz, M. R. (2006) · Pharmaceutical Research · doi:10.1007/s11095-005-8498-8 · Cited by 262
The burden of type 2 diabetes: are we doing enough?
Zimmet, P. (2003) · Diabetes & Metabolism · doi:10.1016/s1262-3636(03)72783-9 · Cited by 260
Factors Affecting the Absorption of Subcutaneously Administered Insulin: Effect on Variability
Gradel, A. K. J., Porsgaard, T., Lykkesfeldt, J., Seested, T., Gram-Nielsen, S., Kristensen, N. R., & Refsgaard, H. H. F. (2018) · Journal of Diabetes Research · doi:10.1155/2018/1205121 · Cited by 202
“In this way, the availability of insulin pumps—which offers the advantage of injection of small volumes—or use of a dispersed injection strategy can facilitate an even more rapid absorption from the SC tissue [108, 109].”
BackgroundDias, C., Abosaleem, B., Crispino, C., Gao, B., & Shaywitz, A. (2015) · AAPS PharmSciTech · doi:10.1208/s12249-015-0288-y · Cited by 63
“Insulin pumps, which deliver a continuous SC infusion, offer an alternative to multiple daily injections for patients with diabetes and have been shown to improve glycemic control and quality of life and reduce vascular complications [16].”
Background
Metadata
- Authors
- Bode, B. W., Sabbah, H. T., Gross, T. M., Fredrickson, L. P., & Davidson, P. C.
- Venue
- Diabetes/Metabolism Research and Reviews
- Publisher
- Wiley
- Published
- 2002-01
- Volume
- 18
- Issue
- S1
- Pages
- S14-S20
- ISSN
- 1520-7552 (ISSN-L)
- 1520-7560
- OpenAlex
- W2070013347
- Cited by
- 156
- References
- 4
- FWCI
- 4.89
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.