Diabetes Device Use in Adults With Type 1 Diabetes: Barriers to Uptake and Potential Intervention Targets
Open accessAbstract
OBJECTIVE Diabetes devices (insulin pumps, continuous glucose monitors [CGMs]) are associated with benefits for glycemic control, yet uptake of these devices continues to be low. Some barriers to device uptake may be modifiable through psychosocial intervention, but little is known about which barriers and which patients to target. RESEARCH DESIGN AND METHODS We surveyed 1,503 adult T1D Exchange participants (mean age 35.3 [SD 14.8] years, mean diagnosis duration 20.4 [SD 12.5] years) to investigate barriers to device uptake, understand profiles of device users versus nonusers, and explore differences by age and sex. Scales used were the Diabetes Distress Scale, Technology Use Attitudes (General and Diabetes-Specific), and Barriers to Device Use and Reasons for Discontinuing Devices. RESULTS Most commonly endorsed modifiable barriers were related to the hassle of wearing devices (47%) and disliking devices on one’s body (35%). CGM users (37%) were older than nonusers (mean 38.3 vs. 33.5 years), had diabetes for longer (22.9 vs. 18.8 years), had more positive technology attitudes (22.6–26.0 vs. 21.4–24.8), and reported fewer barriers to using diabetes technology than nonusers (3.3 vs. 4.3). The youngest age-group (18–25 years) had the lowest CGM (26% vs. 40–48%) and insulin pump (64% vs. 69–77%) uptake, highest diabetes distress (2.2 vs. 1.8–2.1), and highest HbA1c levels (8.3% [67 mmol/mol] vs. 7.2–7.4% [55–57 mmol/mol]). CONCLUSIONS Efforts to increase device use need to target physical barriers to wearing devices. Because young adults had the lowest device uptake rates, highest distress, and highest HbA1c compared with older age-groups, they should be the focus of future interventions to increase device use.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cost of insulin pumps and supplies are the most commonly reported barrier by patients against initiation of insulin pump therapy.
“The cost of insulin pumps and supplies are the most commonly reported barrier by patients against initiation of insulin pump therapy,29”
From Impact of government-funded insulin pump programs on insulin pump use in Canada: a cross-sectional study using the National Diabetes Repository (2021) · cites this paper as [29]
The Results (Aim 1; page unavailable) identify cost of supplies (61%) and cost of device (57%) as the most commonly reported barriers to using diabetes devices. Those figures cover devices generally, not specifically initiation of insulin pump therapy. The paper separately reports that among people who stopped using pumps, discomfort and dislike of wearing a device were more common reasons than cost. (LLM, conf=0.86)
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cites
Continuous glucose monitoring and intensive treatment of type 1 diabetes
(2008) · New England Journal of Medicine · doi:10.1056/nejmoa0805017 · Cited by 1,559 · see citing works
Miller, K. M., Foster, N. C., Beck, R. W., Bergenstal, R. M., DuBose, S. N., DiMeglio, L. A., Maahs, D. M., & Tamborlane, W. V. (2015) · Diabetes Care · doi:10.2337/dc15-0078 · Cited by 1,254 · see citing works
Self-citation
Flagged first, then by citations
Research works printed but not linked: 30
- [2]Phillip M, Battelino T, Rodriguez H, Danne T, Kaufman F; European Society for Paediatric Endocrinology; Lawson Wilkins Pediatric Endocrine Society; International Society for Pediatric and Adolescent Diabetes; American Diabetes Association; European Association for the Study of Diabetes Use of insulin pump therapy in the pediatric age-group: consensus statement from the European Society for Paediatric Endocrinology, the Lawson Wilkins Pediatric Endocrine Society, and the International Society for Pediatric and Adolescent Diabetes, endorsed by the American Diabetes Association and the European Association for the Study of Diabetes. Diabetes Care 2007; 30: 1653– 1662 17372151
- [4]Tamborlane WV, Sherwin RS, Genel M, Felig P Reduction to normal of plasma glucose in juvenile diabetes by subcutaneous administration of insulin with a portable infusion pump. N Engl J Med 1979; 300: 573– 578 763270
- [5]Pickup JC, Keen H, Parsons JA, Alberti KG Continuous subcutaneous insulin infusion: an approach to achieving normoglycaemia. BMJ 1978; 1: 204– 207 340000 PMC1602534
- [6]Bode BW, Sabbah HT, Gross TM, Fredrickson LP, Davidson PC Diabetes management in the new millennium using insulin pump therapy. Diabetes Metab Res Rev 2002; 18(Suppl. 1): S14– S20 11921425
- [8]Klonoff DC Continuous glucose monitoring: roadmap for 21st century diabetes therapy. Diabetes Care 2005; 28: 1231– 1239 15855600
- [9]Wong JC, Foster NC, Maahs DM,.; T1D Exchange Clinic Network Real-time continuous glucose monitoring among participants in the T1D Exchange clinic registry. Diabetes Care 2014; 37: 2702– 2709 25011947 PMC4392936
- [10]Nørgaard K, Scaramuzza A, Bratina N,.; Interpret Study Group Routine sensor-augmented pump therapy in type 1 diabetes: the INTERPRET study. Diabetes Technol Ther 2013; 15: 273– 280 23438304 PMC3696941
- [11]Hermanides J, Phillip M, DeVries JH Current application of continuous glucose monitoring in the treatment of diabetes: pros and cons. Diabetes Care 2011; 34(Suppl. 2): S197– S201 21525455 PMC3632161
- [12]Rubin RR, Peyrot M Treatment satisfaction and quality of life for an integrated continuous glucose monitoring/insulin pump system compared to self-monitoring plus an insulin pump. J Diabetes Sci Technol 2009; 3: 1402– 1410 20144395 PMC2787041
- [13]Modi AC, Pai AL, Hommel KA, Pediatric self-management: a framework for research, practice, and policy. Pediatrics 2012; 129: e473– e485 22218838 PMC9923567
- [14]Ronsin O, Jannot-Lamotte MF, Vague P, Lassman-Vague V Factors related to CSII compliance. Diabetes Metab 2005; 31: 90– 95 15803120
- [15]Cortina S, Repaske DR, Hood KK Sociodemographic and psychosocial factors associated with continuous subcutaneous insulin infusion in adolescents with type 1 diabetes. Pediatr Diabetes 2010; 11: 337– 344 19761529
- [16]de Vries L, Grushka Y, Lebenthal Y, Shalitin S, Phillip M Factors associated with increased risk of insulin pump discontinuation in pediatric patients with type 1 diabetes. Pediatr Diabetes 2011; 12: 506– 512 20723097
- [17]Liberman A, Buckingham B, Phillip M Diabetes technology and the human factor. Diabetes Technol Ther 2014; 16(Suppl. 1): S110– S118 24479592 PMC3920750
- [18]Fisher L, Polonsky WH, Hessler DM, Understanding the sources of diabetes distress in adults with type 1 diabetes. J Diabetes Complications 2015; 29: 572– 577 25765489 PMC4414881
- [19]Benjamini Y, Hochberg Y Controlling the false discovery rate: a practical and powerful approach to multiple testing. J R Stat Soc B 1995; 57: 289– 300
- [20]Bruttomesso D, Costa S, Baritussio A Continuous subcutaneous insulin infusion (CSII) 30 years later: still the best option for insulin therapy. Diabetes Metab Res Rev 2009; 25: 99– 111 19172576
- [21]Shalitin S, Gil M, Nimri R, de Vries L, Gavan MY, Phillip M Predictors of glycaemic control in patients with type 1 diabetes commencing continuous subcutaneous insulin infusion therapy. Diabet Med 2010; 27: 339– 347 20536498
- [22]Deiss D, Bolinder J, Riveline J-P, Improved glycemic control in poorly controlled patients with type 1 diabetes using real-time continuous glucose monitoring. Diabetes Care 2006; 29: 2730– 2732 17130215
- [23]Weissberg-Benchell J, Wolpert H, Anderson BJ Transitioning from pediatric to adult care: a new approach to the post-adolescent young person with type 1 diabetes. Diabetes Care 2007; 30: 2441– 2446 17666466
- [24]Peters A, Laffel L; American Diabetes Association Transitions Working Group Diabetes care for emerging adults: recommendations for transition from pediatric to adult diabetes care systems: a position statement of the American Diabetes Association, with representation by the American College of Osteopathic Family Physicians, the American Academy of Pediatrics, the American Association of Clinical Endocrinologists, the American Osteopathic Association, the Centers for Disease Control and Prevention, Children with Diabetes, The Endocrine Society, the International Society for Pediatric and Adolescent Diabetes, Juvenile Diabetes Research Foundation International, the National Diabetes Education Program, and the Pediatric Endocrine Society (formerly Lawson Wilkins Pediatric Endocrine Society). Diabetes Care 2011; 34: 2477– 2485 22025785 PMC3198284
- [25]Garvey KC, Wolpert HA Identifying the unique needs of transition care for young adults with type 1 diabetes. Diabetes Spectr 2011; 24: 22– 25
- [26]Garvey KC, Markowitz JT, Laffel LM Transition to adult care for youth with type 1 diabetes. Curr Diab Rep 2012; 12: 533– 541 22922877 PMC4080881
- [27]Ritholz MD, Smaldone A, Lee J, Castillo A, Wolpert H, Weinger K Perceptions of psychosocial factors and the insulin pump. Diabetes Care 2007; 30: 549– 554 17327319
- [29]Scheiner G, Sobel RJ, Smith DE, Insulin pump therapy: guidelines for successful outcomes. Diabetes Educ 2009; 35(Suppl. 2): 29S– 41S; quiz 28S, 42S–43S 19318690
- [30]American Association of Diabetes Educators Education for continuous subcutaneous insulin infusion pump users. Diabetes Educ 2003; 29: 97– 99 12645494
- [31]Hill-Briggs F, Gemmell L Problem solving in diabetes self-management and control: a systematic review of the literature. Diabetes Educ 2007; 33: 1032– 1050; discussion 1051–1052 18057272
- [32]Floyd BD, Block JM, Buckingham BB, Stabilization of glycemic control and improved quality of life using a shared medical appointment model in adolescents with type 1 diabetes in suboptimal control. Pediatr Diabetes. 26 February 2016 [Epub ahead of print]. DOI: 10.1111/pedi.12373 26919322 · DOI · Paper page
- [33]Raymond JK, Shea JJ, Berget C, A novel approach to adolescents with type 1 diabetes: the team clinic model. Diabetes Spectr 2015; 28: 68– 71 25717281 PMC4334088
- [34]Barnard KD, Pinsker JE, Oliver N, Astle A, Dassau E, Kerr D Future artificial pancreas technology for type 1 diabetes: what do users want? Diabetes Technol Ther 2015; 17: 311– 315 25629627
Cited by
Sorted by citations
Cappon, G., Vettoretti, M., Sparacino, G., & Facchinetti, A. (2019) · Diabetes & Metabolism Journal · doi:10.4093/dmj.2019.0121 · Cited by 477 · see citing works
ISPAD Clinical Practice Consensus Guidelines 2018: diabetes technologies
Sherr, J. L., Tauschmann, M., Battelino, T., de Bock, M., Forlenza, G., Roman, R., Hood, K. K., & Maahs, D. M. (2018) · Pediatric Diabetes · doi:10.1111/pedi.12731 · Cited by 197 · see citing works
Self-citationvan den Boom, L., Karges, B., Auzanneau, M., Rami-Merhar, B., Lilienthal, E., von Sengbusch, S., Datz, N., Schröder, C., Kapellen, T., Laimer, M., et al. (2019) · Diabetes Care · doi:10.2337/dc19-0345 · Cited by 191 · see citing works
Positioning time in range in diabetes management
Advani, A. (2020) · Diabetologia · doi:10.1007/s00125-019-05027-0 · Cited by 170 · see citing works
Advanced Diabetes Management Using Artificial Intelligence and Continuous Glucose Monitoring Sensors
Vettoretti, M., Cappon, G., Facchinetti, A., & Sparacino, G. (2020) · Sensors · doi:10.3390/s20143870 · Cited by 176 · see citing works
Braune, K., Lal, R. A., Petruželková, L., Scheiner, G., Winterdijk, P., Schmidt, S., Raimond, L., Hood, K. K., Riddell, M. C., Skinner, T. C., et al. (2022) · The Lancet Diabetes & Endocrinology · doi:10.1016/s2213-8587(21)00267-9 · Cited by 130 · see citing works
Self-citationOptimal use of diabetes devices: clinician perspectives on barriers and adherence to device use
Tanenbaum, M. L., Adams, R. N., Hanes, S. J., Barley, R. C., Miller, K. M., Mulvaney, S. A., & Hood, K. K. (2017) · Journal of Diabetes Science and Technology · doi:10.1177/1932296816688010 · Cited by 117 · see citing works
A clinical guide to advanced diabetes devices and closed-loop systems using the CARES paradigm
Messer, L. H., Berget, C., & Forlenza, G. P. (2019) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2019.0105 · Cited by 100 · see citing works
Continuous glucose monitoring: Current use in diabetes management and possible future applications
Vettoretti, M., Cappon, G., Acciaroli, G., Facchinetti, A., & Sparacino, G. (2018) · Journal of Diabetes Science and Technology · doi:10.1177/1932296818774078 · Cited by 96 · see citing works
Avari, P., Uduku, C., George, D., Herrero, P., Reddy, M., & Oliver, N. (2020) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2019.0276 · Cited by 40 · see citing works
Barriers to continuous glucose monitoring in people with type 1 diabetes: clinician perspectives
Lanning, M. S., Tanenbaum, M. L., Wong, J. J., & Hood, K. K. (2020) · Diabetes Spectrum · doi:10.2337/ds19-0039 · Cited by 40 · see citing works
Hendrieckx, C., Poole, L. A., Sharifi, A., Jayawardene, D., Loh, M. M., Horsburgh, J. C., Bach, L. A., Colman, P. G., Kumareswaran, K., Jenkins, A. J., et al. (2017) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2017.0007 · Cited by 37 · see citing works
Identifying the deficiencies of currently available <scp>CGM</scp> to improve uptake and benefit
Barnard‐Kelly, K. D., Martínez‐Brocca, M. A., Glatzer, T., & Oliver, N. (2024) · Diabetic Medicine · doi:10.1111/dme.15338 · Cited by 37 · see citing works
Tack, C. J., Lancee, G. J., Heeren, B., Engelen, L. J., Hendriks, S., Zimmerman, L., De Massari, D., van Gelder, M. M., & van de Belt, T. H. (2018) · JMIR Diabetes · doi:10.2196/diabetes.9531 · Cited by 18 · see citing works
Charleer, S., Gillard, P., Vandoorne, E., Cammaerts, K., Mathieu, C., & Casteels, K. (2020) · Pediatric Diabetes · doi:10.1111/pedi.13128 · Cited by 14 · see citing works
Song, C., Booth, G. L., Perkins, B. A., & Weisman, A. (2021) · BMJ Open Diabetes Research & Care · doi:10.1136/bmjdrc-2021-002371 · Cited by 12 · see citing works
- Authors
- Tanenbaum, M. L., Hanes, S. J., Miller, K. M., Naranjo, D., Bensen, R., & Hood, K. K.
- Affiliations
- Stanford Medicine (US)
- Jaeb Center for Health Research (US)
- Corresponding author
- Hood, Korey K.
- Venue
- Diabetes Care
- Publisher
- American Diabetes Association
- Published
- 2016-11-29
- Volume
- 40
- Issue
- 2
- Pages
- 181-187
- ISSN
- 0149-5992 (ISSN-L)
- 1935-5548
- PMC
- PMC5864141
- OpenAlex
- W2558617381
- Cited by
- 296
- References
- 2
- Citations by year
- 2026: 19 · 2025: 33 · 2024: 31 · 2023: 40 · 2022: 26 · 2021: 45 · 2020: 40 · 2019: 33 · 2018: 18 · 2017: 10
- FWCI
- 20.44
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- Diabetes Care (publishedVersion)
- PubMed Central (publishedVersion)
- PubMed (publishedVersion)
- Funders
- Leona M. and Harry B. Helmsley Charitable Trust
- Topics
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Education
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Genetics › Diabetes and associated disorders
- Keywords
- type 1 diabetes, diabetes technology adoption, insulin pump, continuous glucose monitors, diabetes distress, attitudes toward technology, young adults, glycemic control, HbA1c, psychosocial interventions, sex differences
- MeSH terms
- Adolescent, Adult, Aged, Aged, 80 and over, Blood Glucose, Diabetes Mellitus, Type 1, Female, Glycated Hemoglobin, Humans, Insulin Infusion Systems, Male, Middle Aged, Surveys and Questionnaires, Blood Glucose Self-Monitoring, Young Adult
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review