CoChat

Platelet mean volume, distribution width, and count in type 2 diabetes, impaired fasting glucose, and metabolic syndrome: a meta‐analysis

Zaccardi, Francesco, Rocca, Bianca, Pitocco, Dario, Tanese, Luigi, Rizzi, Alessandro, Ghirlanda, Giovanni · 2015 · Diabetes/Metabolism Research and Reviews
Cited by 116

The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.

Abstract

Background: Platelet activation contributes to cardiovascular disease (CVD), the main complication of type 2 diabetes mellitus (T2DM) and pre‐diabetic conditions. Mean platelet volume is an easy‐to‐measure platelet parameter that has been associated with CVD. We sought to assess mean platelet volume, platelet distribution width, and platelet count in T2DM, impaired fasting glucose (IFG), impaired glucose tolerance (IGT), and metabolic syndrome. Methods: Web‐based literature search (PubMed, EMBASE, and Web of Science) of studies published in English through June 2014 was performed to select case–control and cross‐sectional studies that reported data on mean platelet volume, platelet distribution width, or platelet count in cases (subjects with T2DM, IFG, IGT, or metabolic syndrome) and noncases. Descriptive and quantitative information was extracted, and within‐study standardized mean difference was estimated from means and standard deviations. Standardized mean differences across studies were synthesized using a random random‐effects model, and subgroup analyses were performed on pre‐specified study‐level characteristics. Results: Thirty‐nine studies were included. Compared with controls, mean platelet volume was significantly higher in T2DM (standardized mean difference, 95% confidence interval: 0.70, 0.50–0.91; N = 24 245), IFG (0.14, 0.02–0.26; N = 17 389) but not in metabolic syndrome (0.15, −0.24 to 0.55; N = 14 990). Platelet distribution width was wider in T2DM (0.93, 0.09–1.76; N = 471). Platelet count resulted higher in IFG (0.18, 0.12–0.24; N = 3960) and metabolic syndrome (0.39, 0.01–0.78; N = 4070). Only two studies included IGT. Conclusions: Available data suggest that T2DM subjects tend to have higher mean platelet volume and platelet distribution width values, but nondifferent platelet count as compared with subjects without T2DM. Whether and how these morphometric changes contribute to CVD of T2DM or can be used as CVD biomarker awaits further investigation. Copyright © 2014 John Wiley & Sons, Ltd.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/dmrr.2625

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 6 references

Cited by

Metadata

Authors
Zaccardi, F., Rocca, B., Pitocco, D., Tanese, L., Rizzi, A., & Ghirlanda, G.
Venue
Diabetes/Metabolism Research and Reviews
Publisher
Wiley
Published
2014-12-29
Volume
31
Issue
4
Pages
402-410
ISSN
  • 1520-7552 (ISSN-L)
  • 1520-7560
OpenAlex
W2129454124
Cited by
116
References
6
FWCI
4.55
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.