Deep learning‐based detection and stage grading for optimising diagnosis of diabetic retinopathy
The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Abstract
Aims: To establish an automated method for identifying referable diabetic retinopathy (DR), defined as moderate nonproliferative DR and above, using deep learning‐based lesion detection and stage grading. Materials and Methods: A set of 12,252 eligible fundus images of diabetic patients were manually annotated by 45 licenced ophthalmologists and were randomly split into training, validation, and internal test sets (ratio of 7:1:2). Another set of 565 eligible consecutive clinical fundus images was established as an external test set. For automated referable DR identification, four deep learning models were programmed based on whether two factors were included: DR‐related lesions and DR stages. Sensitivity, specificity and the area under the receiver operating characteristic curve (AUC) were reported for referable DR identification, while precision and recall were reported for lesion detection. Results: Adding lesion information to the five‐stage grading model improved the AUC (0.943 vs. 0.938), sensitivity (90.6% vs. 90.5%) and specificity (80.7% vs. 78.5%) of the model for identifying referable DR in the internal test set. Adding stage information to the lesion‐based model increased the AUC (0.943 vs. 0.936) and sensitivity (90.6% vs. 76.7%) of the model for identifying referable DR in the internal test set. Similar trends were also seen in the external test set. DR lesion types with high precision results were preretinal haemorrhage, hard exudate, vitreous haemorrhage, neovascularisation, cotton wool spots and fibrous proliferation. Conclusions: The herein described automated model employed DR lesions and stage information to identify referable DR and displayed better diagnostic value than models built without this information.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Global prevalence and major risk factors of diabetic retinopathy
Yau, J. W. Y., Rogers, S. L., Kawasaki, R., Lamoureux, E. L., Kowalski, J. W., Bek, T., Chen, S.-J., Dekker, J. M., Fletcher, A., Grauslund, J., et al. (2012) · Diabetes Care · doi:10.2337/dc11-1909 · Cited by 4,985
Self-citationSTARD 2015: an updated list of essential items for reporting diagnostic accuracy studies
Bossuyt, P. M., Reitsma, J. B., Bruns, D. E., Gatsonis, C. A., Glasziou, P. P., Irwig, L., Lijmer, J. G., Moher, D., Rennie, D., de Vet, H. C. W., et al. (2015) · BMJ · doi:10.1136/bmj.h5527 · Cited by 3,660 · cited 1×
“29 The The referral kappa was used to evaluate the referral consistency between two annotators.”
MethodFlaxman, S. R., Bourne, R. R. A., Resnikoff, S., Ackland, P., Braithwaite, T., Cicinelli, M. V., Das, A., Jonas, J. B., Keeffe, J., Kempen, J. H., et al. (2017) · The Lancet Global Health · doi:10.1016/s2214-109x(17)30393-5 · Cited by 3,477
Self-citationPrevalence of Diabetes among Men and Women in China
Yang, W., Lu, J., Weng, J., Jia, W., Ji, L., Xiao, J., Shan, Z., Liu, J., Tian, H., Ji, Q., et al. (2010) · New England Journal of Medicine · doi:10.1056/nejmoa0908292 · Cited by 3,031 · cited 1×
“1‐3 The situation is similarly severe in China, which has more than 100 million diabetic patients with a DR prevalence rate of approximately 30%.(4) Early screening for DR based on colour fundus images is well recognised as an effective measure to prevent blindness.”
BackgroundTing, D. S. W., Cheung, C. Y.-L., Lim, G., Tan, G. S. W., Quang, N. D., Gan, A., Hamzah, H., Garcia-Franco, R., San Yeo, I. Y., Lee, S. Y., et al. (2017) · JAMA · doi:10.1001/jama.2017.18152 · Cited by 2,402
Artificial intelligence and deep learning in ophthalmology
Ting, D. S. W., Pasquale, L. R., Peng, L., Campbell, J. P., Lee, A. Y., Raman, R., Tan, G. S. W., Schmetterer, L., Keane, P. A., & Wong, T. Y. (2019) · British Journal of Ophthalmology · doi:10.1136/bjophthalmol-2018-313173 · Cited by 1,554 · cited 2×
“30,31 For eachpredictedconnected component of the lesion, if over 50% of the pixels were covered by the ground truth, the predicted lesion was considered correct.”
BackgroundAbràmoff, M. D., Lou, Y., Erginay, A., Clarida, W., Amelon, R., Folk, J. C., & Niemeijer, M. (2016) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.16-19964 · Cited by 1,101
Artificial intelligence in retina
Schmidt-Erfurth, U., Sadeghipour, A., Gerendas, B. S., Waldstein, S. M., & Bogunović, H. (2018) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2018.07.004 · Cited by 779 · cited 1×
“Deep learning relies heavily on the input and output information to construct complex neural networks in the hidden layers.(31,32) Therefore, we speculate that with detailed information given—for example, lesion information or DR stage information—the computer”
BackgroundLi, Z., Keel, S., Liu, C., He, Y., Meng, W., Scheetz, J., Lee, P. Y., Shaw, J., Ting, D., Wong, T. Y., et al. (2018) · Diabetes Care · doi:10.2337/dc18-0147 · Cited by 255 · cited 1×
“The upper branch adopted the convolutional layers of the well‐recognised Inception‐v3 model,(18,26) which was originally designed for referable/nonreferable DR classification.(15,18,27) In the lower branch, we used a fully convolutional network (FCN‐32s) to give pixelwise lesion segmentation predictions.”
MethodRuamviboonsuk, P., Krause, J., Chotcomwongse, P., Sayres, R., Raman, R., Widner, K., Campana, B. J. L., Phene, S., Hemarat, K., Tadarati, M., et al. (2019) · npj Digital Medicine · doi:10.1038/s41746-019-0099-8 · Cited by 233
Li, F., Liu, Z., Chen, H., Jiang, M., Zhang, X., & Wu, Z. (2019) · Translational Vision Science & Technology · doi:10.1167/tvst.8.6.4 · Cited by 144 · cited 1×
“The upper branch adopted the convolutional layers of the well ‐ recognised Inception ‐ v3 model, 18,26 which was originally designed for referable/nonreferable DR classification.”
MethodSelf-citation
Cited by
Artificial intelligence promotes the diagnosis and screening of diabetic retinopathy
Huang, X., Wang, H., She, C., Feng, J., Liu, X., Hu, X., Chen, L., & Tao, Y. (2022) · Frontiers in Endocrinology · doi:10.3389/fendo.2022.946915 · Cited by 115
Artificial intelligence for early detection of diabetes mellitus complications via retinal imaging
Sobhi, N., Sadeghi-Bazargani, Y., Mirzaei, M., Abdollahi, M., Jafarizadeh, A., Pedrammehr, S., Alizadehsani, R., Tan, R.-S., Islam, S. M. S., & Acharya, U. R. (2025) · Journal of Diabetes & Metabolic Disorders · doi:10.1007/s40200-025-01596-7 · Cited by 39
Elsharkawy, M., Elrazzaz, M., Sharafeldeen, A., Alhalabi, M., Khalifa, F., Soliman, A., Elnakib, A., Mahmoud, A., Ghazal, M., El-Daydamony, E., et al. (2022) · Sensors · doi:10.3390/s22093490 · Cited by 38
(2022) · doi:10.1186/s12909-022-03272-3 · Cited by 30
Metadata
- Authors
- Wang, Y., Yu, M., Hu, B., Jin, X., Li, Y., Zhang, X., Zhang, Y., Gong, D., Wu, C., Zhang, B., Yang, J., Li, B., Yuan, M., Mo, B., Wei, Q., Zhao, J., Ding, D., Yang, J., Li, X., Yu, W., & Chen, Y.
- Venue
- Diabetes/Metabolism Research and Reviews
- Publisher
- Wiley
- Published
- 2021-03-13
- Volume
- 37
- Issue
- 4
- Pages
- e3445-e3445
- ISSN
- 1520-7552 (ISSN-L)
- 1520-7560
- OpenAlex
- W3138379014
- Cited by
- 43
- References
- 11
- FWCI
- 3.40
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.