CoChat
Cited by 272

The DOI matches its Crossref record; 49 of the 49 references it cites were found in a registry or an index.

Cardiovascular complications of anorexia nervosa: A systematic review

Sachs, Katherine V., Harnke, Ben, Mehler, Philip S., Krantz, Mori J. · 2016 · International Journal of Eating Disorders

Abstract

Objective: Anorexia nervosa portends the highest mortality among psychiatric diseases, despite primarily being a disease of adolescents and younger adults. Although some of this mortality risk is attributable to suicide, many deaths are likely cardiovascular in etiology. Recent studies suggest that adverse myocardial structural changes occur in this condition, which could underlie the increased mortality. Given limited prevalence of severe anorexia there is a paucity of clinical and autopsy data to discern an exact cause of death. Methods: Given this background we conducted a systematic review of the medical literature to provide a contemporary summary of the pathobiologic sequelae of severe anorexia nervosa on the cardiovascular system. We sought to elucidate the impact of anorexia nervosa in four cardiovascular domains: structural, repolarization/conduction, hemodynamic, and peripheral vascular. Results: A number of cardiac abnormalities associated with anorexia nervosa have been described in the literature, including pericardial and valvular pathology, changes in left ventricular mass and function, conduction abnormalities, bradycardia, hypotension, and dysregulation in peripheral vascular contractility. Despite the prevalent theory that malignant arrhythmias are implicated as a cause of sudden death in this disorder, data to support this causal relationship are lacking. Discussion: It is reasonable to obtain routine electrocardiography and measurements of orthostatic vital signs in patients presenting with anorexia nervosa. Echocardiography is generally not indicated unless prompted by clinical signs of disease. Admission to an inpatient unit with telemetry monitoring is recommended for patients with severe sinus bradycardia or junction rhythm, marked prolongation of the corrected QT interval, or syncope.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/eat.22481

Cites

49 of 49 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 49 references

Cited by

Metadata

Authors
Sachs, K. V., Harnke, B., Mehler, P. S., & Krantz, M. J.
Venue
International Journal of Eating Disorders
Publisher
Wiley
Published
2015-12-29
Volume
49
Issue
3
Pages
238-248
ISSN
  • 0276-3478 (ISSN-L)
  • 1098-108X
OpenAlex
W2216025744
Cited by
272
References
49
FWCI
1.72
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.