CoChat

Primary results of long‐term outcomes in the MOMENTUM 3 pivotal trial and continued access protocol study phase: a study of 2200 HeartMate 3 left ventricular assist device implants

Open access
Mehra, Mandeep R., Cleveland, Joseph C., Uriel, Nir, Cowger, Jennifer A., Hall, Shelley, Horstmanshof, Douglas, Naka, Yoshifumi, Salerno, Christopher T., Chuang, Joyce, Williams, Christopher, Goldstein, Daniel J., on behalf of the MOMENTUM 3 Investigators · 2021 · European Journal of Heart Failure
Cited by 183

The DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.

Abstract

Aim: The MOMENTUM 3 pivotal trial established superiority of the HeartMate 3 (HM3) left ventricular assist device (LVAD), a fully magnetically levitated centrifugal‐flow pump, over the HeartMate II axial‐flow pump. We now evaluate HM3 LVAD outcomes in a single‐arm prospective continuous access protocol (CAP) post‐pivotal trial study. Methods and results: We enrolled 2200 HM3 implanted patients (515 pivotal trial and 1685 CAP patients) and compared outcomes including survival free of disabling stroke or reoperation to replace or remove a malfunctioning device (primary composite endpoint), overall survival and major adverse events at 2 years. The 2‐year primary endpoint [76.7% vs. 74.8%; adjusted hazard ratio (HR) 0.87, 95% confidence interval (CI) 0.71–1.08, P = 0.21] and overall survival (81.2% vs. 79.0%) were similar among CAP and pivotal cohorts despite sicker patients (more intra‐aortic balloon pump use and INTERMACS profile 1) in CAP who were more often intended for destination therapy. Survival was similar between the CAP and pivotal trial in transplant ineligible patients (79.1% vs. 76.7%; adjusted HR 0.89, 95% CI 0.68–1.16, P = 0.38). In a pooled analysis, the 2‐year primary endpoint was similar between INTERMACS profiles 1–2 (‘unstable’ advanced heart failure), profile 3 (‘stable’ on inotropic therapy), and profiles 4–7 (‘stable’ ambulatory advanced heart failure) (75.7% vs. 77.6% vs. 72.9%, respectively). The net burden of adverse events was lower in CAP (adjusted rate ratio 0.93, 95% CI 0.88–0.98, P = 0.006), with consequent decrease in hospitalization. Conclusions: The primary results of accumulating HM3 LVAD experience suggest a lower adverse event burden and similar survival compared to the pivotal MOMENTUM 3 trial.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/ejhf.2211

Cites

21 of 21 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 183

Metadata

Authors
Mehra, M. R., Cleveland, J. C., Uriel, N., Cowger, J. A., Hall, S., Horstmanshof, D., Naka, Y., Salerno, C. T., Chuang, J., Williams, C., Goldstein, D. J., & on behalf of the MOMENTUM 3 Investigators
Venue
European Journal of Heart Failure
Published
2021-05-18
Volume
23
Issue
8
Pages
1392-1400
ISSN
  • 1388-9842 (ISSN-L)
  • 1879-0844
OpenAlex
W3159511774
Cited by
183
References
21
FWCI
8.61
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.