Enzyme‐catalyzed direct electron transfer: Fundamentals and analytical applications
The DOI matches its Crossref record; 44 of the 44 references it cites were found in a registry or an index.
Abstract
This article overviews the fundamentals of the phenomenon of direct electron transfer in enzyme‐catalyzed electrode reactions and the development of electroanalytical applications of the bioelectrocatalytic systems. A brief description of the enzymes capable of catalyzing electrochemical reactions by means of direct electron transfer is given. The physico‐chemical background of bioelectrocatalysis is discussed in terms of the different concepts underlying the mechanism of electron transfer. The concept of a “molecular transducer” is introduced to designate a complex, formed by the electrocatalytically active enzyme on the electrode‐electrolyte interface, which is directly responsible for the transduction of the chemical signal to an electric one. The role of this “molecular transducer” in enzyme electrodes and immunoelectrodes is discussed. The analytical applications of bioelectrocatalysis are categorized as systems employing either amperometric or potentiometric detection. Discussion focuses on the advantages of systems based on enzyme‐catalyzed direct electron transfer as opposed to other enzyme‐catalyzed electroanalytical devices. In conclusion, the trends towards upcoming practical applications are suggested as well as some directions in fundamental studies of bioelectrocatalysis as a phenomenon.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Mayer, A. M., & Harel, E. (1979) · Phytochemistry · doi:10.1016/0031-9422(79)80057-6 · Cited by 1,258
Biosensors. Fundamentals and Applications
Kell, D. (1988) · Bioelectrochemistry and Bioenergetics · doi:10.1016/0302-4598(88)80042-4 · Cited by 601
Peroxidase-modified electrodes: Fundamentals and application
Ruzgas, T., Csöregi, E., Emnéus, J., Gorton, L., & Marko-Varga, G. (1996) · Analytica Chimica Acta · doi:10.1016/0003-2670(96)00169-9 · Cited by 522
Carbon paste electrodes modified with enzymes, tissues, and cells
Gorton, L. (1995) · Electroanalysis · doi:10.1002/elan.1140070104 · Cited by 515
Direct electron transfer at horseradish peroxidase—colloidal gold modified electrodes
Zhao, J., Henkens, R. W., Stonehuerner, J., O'Daly, J. P., & Crumbliss, A. L. (1992) · Journal of Electroanalytical Chemistry · doi:10.1016/0022-0728(92)80140-y · Cited by 293
Gorton, L., Csöregi, E., Domínguez, E., Emnéus, J., Jönsson-Pettersson, G., Marko-Varga, G., & Persson, B. (1991) · Analytica Chimica Acta · doi:10.1016/0003-2670(91)85072-z · Cited by 225
Diode-like behaviour of a mitochondrial electron-transport enzyme
Sucheta, A., Ackrell, B. A. C., Cochran, B., & Armstrong, F. A. (1992) · Nature · doi:10.1038/356361a0 · Cited by 183
- Amperometric Enzyme Electrodes
(2015) · Electrochemical Biosensors · doi:10.1201/b15659-6 · Cited by 181
Amperometric enzyme electrodes
Albery, W. J., Bartlett, P. N., & Craston, D. H. (1985) · Journal of Electroanalytical Chemistry and Interfacial Electrochemistry · doi:10.1016/0022-0728(85)85006-3 · Cited by 170
Yaropolov, A. I., Kharybin, A. N., Emnéus, J., Marko-Varga, G., & Gorton, L. (1995) · Analytica Chimica Acta · doi:10.1016/0003-2670(94)00404-a · Cited by 161
Gorton, L. G. O., Bremle, G., Csöregi, E., Jönsson–Pettersson, G., & Persson, B. (1991) · Analytica Chimica Acta · doi:10.1016/0003-2670(91)87006-s · Cited by 157
The determination of p-cresol in chloroform with an enzyme electrode used in the organic phase
Hall, G. F., Best, D. J., & Turner, A. P. F. (1988) · Analytica Chimica Acta · doi:10.1016/s0003-2670(00)81345-8 · Cited by 156
Sucheta, A., Cammack, R., Weiner, J., & Armstrong, F. A. (1993) · Biochemistry · doi:10.1021/bi00071a023 · Cited by 152
Peroxidase-incorporated polypyrrole membrane electrodes
Tatsuma, T., Gondaira, M., & Watanabe, T. (1992) · Analytical Chemistry · doi:10.1021/ac00034a019 · Cited by 143
Ikeda, T., Kobayashi, D., Matsushita, F., Sagara, T., & Niki, K. K. (1993) · Journal of Electroanalytical Chemistry · doi:10.1016/0022-0728(93)87058-4 · Cited by 140
Catalysis of the reduction of dioxygen at graphite electrodes coated with fungal laccase A
Lee, C., Gray, H. B., Anson, F. C., & Malmström, B. G. (1984) · Journal of Electroanalytical Chemistry · doi:10.1016/0022-0728(84)80193-x · Cited by 132
293 - Electrocatalysis of a cathodic oxygen reduction by laccase
Tarasevich, M. R., Yaropolov, A. I., Bogdanovskaya, V. A., & Varfolomeev, S. D. (1979) · Bioelectrochemistry and Bioenergetics · doi:10.1016/0302-4598(79)80006-9 · Cited by 131
Csöregi, E., Jönsson–Pettersson, G., & Gorton, L. G. O. (1993) · Journal of Biotechnology · doi:10.1016/0168-1656(93)90147-f · Cited by 128
Electron exchange between the enzyme active center and organic metal
Kulys, J. J., Samalius, A. S., & Švirmickas, G. J. (1980) · FEBS Letters · doi:10.1016/0014-5793(80)80849-0 · Cited by 127
Amperometric enzyme electrodes
Albery, W. J., & Bartlett, P. N. (1985) · Journal of Electroanalytical Chemistry · doi:10.1016/0022-0728(85)85005-1 · Cited by 127
Hirst, J., Sucheta, A., Ackrell, B. A. C., & Armstrong, F. A. (1996) · Journal of the American Chemical Society · doi:10.1021/ja9534361 · Cited by 114
du Poët, P. D. T., Miyamoto, S., Murakami, T., Kimura, J., & Karube, I. (1990) · Analytica Chimica Acta · doi:10.1016/s0003-2670(00)82082-6 · Cited by 108
Khan, G. F., Ohwa, M., & Wernet, W. (1996) · Analytical Chemistry · doi:10.1021/ac9510393 · Cited by 98
Enzyme electrodes based on organic metals
Kalys, J. J. (1986) · Biosensors · doi:10.1016/0265-928x(86)85009-x · Cited by 95
Bienzyme sensors based on “electrically wired” peroxidase
Ohara, T. J., Vreeke, M. S., Battaglini, F., & Heller, A. (1993) · Electroanalysis · doi:10.1002/elan.1140050917 · Cited by 89
Amperometric enzyme electrodes
Albery, W. J., Bartlett, P. N., & Cass, A. E. G. (1987) · Philosophical transactions of the Royal Society of London. Series B, Biological sciences · doi:10.1098/rstb.1987.0021 · Cited by 89
Electro-conductive enzyme membrane
Yabuki, S., Shinohara, H., & Aizawa, M. (1989) · Journal of the Chemical Society Chemical Communications · doi:10.1039/c39890000945 · Cited by 88
Mondal, M. S., Fuller, H. A., & Armstrong, F. A. (1996) · Journal of the American Chemical Society · doi:10.1021/ja952489f · Cited by 83
Koopal, C. G. J., de Ruiter, B., & Nolte, R. J. M. (1991) · Journal of the Chemical Society Chemical Communications · doi:10.1039/c39910001691 · Cited by 80
Immobilized xanthine oxidase chemically modified electrode as a dual analytical sensor
Ianniello, R. M., Lindsay, T. J., & Yacynych, A. M. (1982) · Analytical Chemistry · doi:10.1021/ac00249a015 · Cited by 78
413 — Biocatalytic oxidation of glucose on the conductive charge transfer complexes
Čėnas, N., & Kulys, J. J. (1981) · Bioelectrochemistry and Bioenergetics · doi:10.1016/0302-4598(81)85011-8 · Cited by 78
Glucose sensor utilizing polypyrrole incorporated in tract-etch membranes as the mediator
Koopal, C. G. J., Feiters, M. C., Nolte, R. J. M., de Ruiter, B., & Schasfoort, R. B. M. (1992) · Biosensors and Bioelectronics · doi:10.1016/0956-5663(92)80003-t · Cited by 77
Clinical diagnostics opportunities for biosensors and bioelectronics
Connolly, P. (1995) · Biosensors and Bioelectronics · doi:10.1016/0956-5663(95)96789-2 · Cited by 70
Csöregi, E., Gorton, L. G. O., & Marko‐Varga, G. (1993) · Analytica Chimica Acta · doi:10.1016/0003-2670(93)80145-b · Cited by 66
Reagentless oxidoreductase sensors
Schmidt, H., & Schuhmann, W. W. (1996) · Biosensors and Bioelectronics · doi:10.1016/0956-5663(96)83720-1 · Cited by 63
Ho, W. O., Athey, D., McNeil, C. J., Hager, H. J., Evans, G. P., & Mullen, W. H. (1993) · Journal of Electroanalytical Chemistry · doi:10.1016/0022-0728(93)80233-8 · Cited by 61
Tatsuma, T., Watanabe, T., & Watanabe, T. (1993) · Journal of Electroanalytical Chemistry · doi:10.1016/0022-0728(93)80523-k · Cited by 58
Biocatalytic oxidation of glucose on the conductive charge transfer complexes
Čėnas, N., & Kulys, J. J. (1981) · Journal of Electroanalytical Chemistry · doi:10.1016/s0022-0728(81)80191-x · Cited by 42
Farver, O., & Pecht, I. (1994) · Biophysical Chemistry · doi:10.1016/0301-4622(94)85032-1 · Cited by 41
Redox conversion of peroxidase on surface-modified gold electrode
Razumas, V. J., Gudavičius, A. V., & Kulys, J. J. (1983) · Journal of Electroanalytical Chemistry · doi:10.1016/s0022-0728(83)80446-x · Cited by 40
Bioelectrocatalytic conversion of substances on polymer-modified electrodes
Čėnas, N., Pocius, A. K., & Kulys, J. J. (1984) · Bioelectrochemistry and Bioenergetics · doi:10.1016/0302-4598(84)85100-4 · Cited by 29
Č≐nas, N., Pocius, A. K., & Kulys, J. J. (1983) · Bioelectrochemistry and Bioenergetics · doi:10.1016/0302-4598(83)85101-0 · Cited by 28
Csöregi, E., Gorton, L. G. O., & Marko‐Varga, G. (1994) · Electroanalysis · doi:10.1002/elan.1140061103 · Cited by 26
Tatsuma, T., Ariyama, K., & Oyama, N. (1996) · Analytica Chimica Acta · doi:10.1016/0003-2670(95)00451-3 · Cited by 18
Cited by
Gold Nanoparticles in Chemical and Biological Sensing
Saha, K., Agasti, S. S., Kim, C., Li, X., & Rotello, V. M. (2012) · Chemical Reviews · doi:10.1021/cr2001178 · Cited by 4,620
Electrochemical Glucose Biosensors
Wang, J. (2008) · Chemical Reviews · doi:10.1021/cr068123a · Cited by 3,498
Graphene Based Electrochemical Sensors and Biosensors: A Review
Shao, Y., Wang, J., Wu, H., Liu, J., Aksay, I. A., & Lin, Y. (2010) · Electroanalysis · doi:10.1002/elan.200900571 · Cited by 3,124
Electrochemical Biosensors - Sensor Principles and Architectures
Grieshaber, D., MacKenzie, R., Vörös, J., & Reimhult, E. (2008) · Sensors · doi:10.3390/s80314000 · Cited by 2,329
“A high efficiency of the enzymatic reaction is required [4, 204].”
BackgroundEnzymatic Biofuel Cells for Implantable and Microscale Devices
Calabrese Barton, S., Gallaway, J., & Atanassov, P. (2004) · Chemical Reviews · doi:10.1021/cr020719k · Cited by 1,394
Metadata
- Authors
- Ghindilis, A. L., Atanasov, P., & Wilkins, E.
- Venue
- Electroanalysis
- Publisher
- Wiley
- Published
- 1997-05
- Volume
- 9
- Issue
- 9
- Pages
- 661-674
- ISSN
- 1040-0397 (ISSN-L)
- 1521-4109
- OpenAlex
- W1973816733
- Cited by
- 440
- References
- 44
- FWCI
- 12.57
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.