Enzyme‐catalyzed direct electron transfer: Fundamentals and analytical applications
The DOI matches its Crossref record; 44 of the 44 references it cites were found in a registry or an index.
Abstract
This article overviews the fundamentals of the phenomenon of direct electron transfer in enzyme‐catalyzed electrode reactions and the development of electroanalytical applications of the bioelectrocatalytic systems. A brief description of the enzymes capable of catalyzing electrochemical reactions by means of direct electron transfer is given. The physico‐chemical background of bioelectrocatalysis is discussed in terms of the different concepts underlying the mechanism of electron transfer. The concept of a “molecular transducer” is introduced to designate a complex, formed by the electrocatalytically active enzyme on the electrode‐electrolyte interface, which is directly responsible for the transduction of the chemical signal to an electric one. The role of this “molecular transducer” in enzyme electrodes and immunoelectrodes is discussed. The analytical applications of bioelectrocatalysis are categorized as systems employing either amperometric or potentiometric detection. Discussion focuses on the advantages of systems based on enzyme‐catalyzed direct electron transfer as opposed to other enzyme‐catalyzed electroanalytical devices. In conclusion, the trends towards upcoming practical applications are suggested as well as some directions in fundamental studies of bioelectrocatalysis as a phenomenon.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Mayer, A. M., & Harel, E. (1979) · Phytochemistry · doi:10.1016/0031-9422(79)80057-6 · Cited by 1,258
Biosensors. Fundamentals and Applications
Kell, D. (1988) · Bioelectrochemistry and Bioenergetics · doi:10.1016/0302-4598(88)80042-4 · Cited by 601
Peroxidase-modified electrodes: Fundamentals and application
Ruzgas, T., Csöregi, E., Emnéus, J., Gorton, L., & Marko-Varga, G. (1996) · Analytica Chimica Acta · doi:10.1016/0003-2670(96)00169-9 · Cited by 522
Carbon paste electrodes modified with enzymes, tissues, and cells
Gorton, L. (1995) · Electroanalysis · doi:10.1002/elan.1140070104 · Cited by 515
Direct electron transfer at horseradish peroxidase—colloidal gold modified electrodes
Zhao, J., Henkens, R. W., Stonehuerner, J., O'Daly, J. P., & Crumbliss, A. L. (1992) · Journal of Electroanalytical Chemistry · doi:10.1016/0022-0728(92)80140-y · Cited by 293
Gorton, L., Csöregi, E., Domínguez, E., Emnéus, J., Jönsson-Pettersson, G., Marko-Varga, G., & Persson, B. (1991) · Analytica Chimica Acta · doi:10.1016/0003-2670(91)85072-z · Cited by 225
Diode-like behaviour of a mitochondrial electron-transport enzyme
Sucheta, A., Ackrell, B. A. C., Cochran, B., & Armstrong, F. A. (1992) · Nature · doi:10.1038/356361a0 · Cited by 183
- Amperometric Enzyme Electrodes
(2015) · Electrochemical Biosensors · doi:10.1201/b15659-6 · Cited by 181
Amperometric enzyme electrodes
Albery, W. J., Bartlett, P. N., & Craston, D. H. (1985) · Journal of Electroanalytical Chemistry and Interfacial Electrochemistry · doi:10.1016/0022-0728(85)85006-3 · Cited by 170
Yaropolov, A. I., Kharybin, A. N., Emnéus, J., Marko-Varga, G., & Gorton, L. (1995) · Analytica Chimica Acta · doi:10.1016/0003-2670(94)00404-a · Cited by 161
Cited by
Gold Nanoparticles in Chemical and Biological Sensing
Saha, K., Agasti, S. S., Kim, C., Li, X., & Rotello, V. M. (2012) · Chemical Reviews · doi:10.1021/cr2001178 · Cited by 4,620
Electrochemical Glucose Biosensors
Wang, J. (2008) · Chemical Reviews · doi:10.1021/cr068123a · Cited by 3,498
Graphene Based Electrochemical Sensors and Biosensors: A Review
Shao, Y., Wang, J., Wu, H., Liu, J., Aksay, I. A., & Lin, Y. (2010) · Electroanalysis · doi:10.1002/elan.200900571 · Cited by 3,124
Electrochemical Biosensors - Sensor Principles and Architectures
Grieshaber, D., MacKenzie, R., Vörös, J., & Reimhult, E. (2008) · Sensors · doi:10.3390/s80314000 · Cited by 2,329
“A high efficiency of the enzymatic reaction is required [4, 204].”
BackgroundEnzymatic Biofuel Cells for Implantable and Microscale Devices
Calabrese Barton, S., Gallaway, J., & Atanassov, P. (2004) · Chemical Reviews · doi:10.1021/cr020719k · Cited by 1,394
Synthesis and electrochemical applications of gold nanoparticles
Guo, S., & Wang, E. (2007) · Analytica Chimica Acta · doi:10.1016/j.aca.2007.07.054 · Cited by 693
Jia, J., Wang, B., Wu, A., Cheng, G., Li, Z., & Dong, S. (2002) · Analytical Chemistry · doi:10.1021/ac011116w · Cited by 653
Direct electron transfer between copper-containing proteins and electrodes
Shleev, S., Tkac, J., Christenson, A., Ruzgas, T., Yaropolov, A. I., Whittaker, J. W., & Gorton, L. (2005) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2004.10.003 · Cited by 621
Recent advances in ZnO nanostructures and thin films for biosensor applications: Review
Arya, S. K., Saha, S., Ramirez-Vick, J. E., Gupta, V., Bhansali, S., & Singh, S. P. (2012) · Analytica Chimica Acta · doi:10.1016/j.aca.2012.05.048 · Cited by 579
Challenges in biocatalysis for enzyme-based biofuel cells
Kim, J., Jia, H., & Wang, P. (2006) · Biotechnology Advances · doi:10.1016/j.biotechadv.2005.11.006 · Cited by 554
The ins and outs of microorganism–electrode electron transfer reactions
Kumar, A., Hsu, L. H.-H., Kavanagh, P., Barrière, F., Lens, P. N. L., Lapinsonnière, L., Lienhard V, J. H., Schröder, U., Jiang, X., & Leech, D. (2017) · Nature Reviews Chemistry · doi:10.1038/s41570-017-0024 · Cited by 541
Tackling the Challenges of Enzymatic (Bio)Fuel Cells
Xiao, X., Xia, H.-Q., Wu, R., Bai, L., Yan, L., Magner, E., Cosnier, S., Lojou, E., Zhu, Z., & Liu, A. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.9b00115 · Cited by 504
Fundamentals, Applications, and Future Directions of Bioelectrocatalysis
Chen, H., Simoska, O., Lim, K., Grattieri, M., Yuan, M., Dong, F., Lee, Y. S., Beaver, K., Weliwatte, S., Gaffney, E. M., et al. (2020) · Chemical Reviews · doi:10.1021/acs.chemrev.0c00472 · Cited by 492
Implanted Biofuel Cell Operating in a Living Snail
Halámková, L., Halámek, J., Bocharova, V., Szczupak, A., Alfonta, L., & Katz, E. (2012) · Journal of the American Chemical Society · doi:10.1021/ja211714w · Cited by 486
Electrochemical biosensors and nanobiosensors
Hammond, J. L., Formisano, N., Estrela, P., Carrara, S., & Tkac, J. (2016) · Essays in Biochemistry · doi:10.1042/ebc20150008 · Cited by 425
Enzyme catalysed biofuel cells
Cooney, M. J., Svoboda, V., Lau, C., Martin, G., & Minteer, S. D. (2008) · Energy & Environmental Science · doi:10.1039/b809009b · Cited by 391
Noble metal nanoparticles in biosensors: recent studies and applications
Malekzad, H., Sahandi Zangabad, P., Mirshekari, H., Karimi, M., & Hamblin, M. R. (2017) · Nanotechnology Reviews · doi:10.1515/ntrev-2016-0014 · Cited by 375
Emerging synergy between nanotechnology and implantable biosensors: A review
Vaddiraju, S., Tomazos, I., Burgess, D. J., Jain, F. C., & Papadimitrakopoulos, F. (2010) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2009.12.001 · Cited by 368
Extended lifetime biofuel cells
Moehlenbrock, M. J., & Minteer, S. D. (2008) · Chemical Society Reviews · doi:10.1039/b708013c · Cited by 351
Immobilization of uricase on ZnO nanorods for a reagentless uric acid biosensor
Zhang, F., Wang, X., Ai, S., Sun, Z., Wan, Q., Zhu, Z., Xian, Y., Jin, L., & Yamamoto, K. (2004) · Analytica Chimica Acta · doi:10.1016/j.aca.2004.05.070 · Cited by 348
Fructose/dioxygen biofuel cell based on direct electron transfer-type bioelectrocatalysis
Kamitaka, Y., Tsujimura, S., Setoyama, N., Kajino, T., & Kano, K. (2007) · Physical Chemistry Chemical Physics · doi:10.1039/b617650j · Cited by 335
Janata, J., Josowicz, M., Vanýsek, P., & DeVaney, D. M. (1998) · Analytical Chemistry · doi:10.1021/a1980010w · Cited by 330
Paleček, E., Tkáč, J., Bartošík, M., Bertók, T., Ostatná, V., & Paleček, J. (2015) · Chemical Reviews · doi:10.1021/cr500279h · Cited by 319
The Role of Electrochemical Immunosensors in Clinical Analysis
Mollarasouli, F., Kurbanoglu, S., & Ozkan, S. A. (2019) · Biosensors · doi:10.3390/bios9030086 · Cited by 293
Glucose oxidase anode for biofuel cell based on direct electron transfer
Ivnitski, D., Branch, B., Atanassov, P., & Apblett, C. (2006) · Electrochemistry Communications · doi:10.1016/j.elecom.2006.05.024 · Cited by 291
Living battery – biofuel cells operating in vivo in clams
Szczupak, A., Halámek, J., Halámková, L., Bocharova, V., Alfonta, L., & Katz, E. (2012) · Energy & Environmental Science · doi:10.1039/c2ee21626d · Cited by 259
Recent progress and continuing challenges in bio-fuel cells. Part I: Enzymatic cells
Osman, M. H., Shah, A. A., & Walsh, F. C. (2011) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2011.01.004 · Cited by 257
Recent advances on developing 3rd generation enzyme electrode for biosensor applications
Das, P., Das, M., Chinnadayyala, S. R., Singha, I. M., & Goswami, P. (2016) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2015.12.055 · Cited by 239
Enzyme-Based Biosensors: Tackling Electron Transfer Issues
Bollella, P., & Katz, E. (2020) · Sensors · doi:10.3390/s20123517 · Cited by 195
Third-Generation Biosensors Based on the Direct Electron Transfer of Proteins
Zhang, W., & Li, G. (2004) · Analytical Sciences · doi:10.2116/analsci.20.603 · Cited by 192
Zhao, S., Zhang, K., Bai, Y., Yang, W., & Sun, C. (2006) · Bioelectrochemistry · doi:10.1016/j.bioelechem.2006.01.001 · Cited by 192
Schuhmann, W. (2002) · Reviews in Molecular Biotechnology · doi:10.1016/s1389-0352(01)00058-7 · Cited by 166
Current trends in the development of conducting polymers-based biosensors
Ghorbani Zamani, F., Moulahoum, H., Ak, M., Odaci Demirkol, D., & Timur, S. (2019) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2019.05.031 · Cited by 161
Electroanalysis and Biosensors
Wang, J. (1999) · Analytical Chemistry · doi:10.1021/a1999905e · Cited by 159
Gold nanoparticles: an era in bionanotechnology
Kumar, D., Saini, N., Jain, N., Sareen, R., & Pandit, V. (2013) · Expert Opinion on Drug Delivery · doi:10.1517/17425247.2013.749854 · Cited by 96
“5 Analytical applications Gold nanoparticles possess excellent biocompatibility and unique structural, electronic, magnetic, optical and catalytic properties which make them attractive material for biosensor, chemisensor and electrocatalyst [105-107].”
BackgroundNitrogenase Bioelectrochemistry for Synthesis Applications
Milton, R. D., & Minteer, S. D. (2019) · Accounts of Chemical Research · doi:10.1021/acs.accounts.9b00494 · Cited by 92
Metadata
- Authors
- Ghindilis, A. L., Atanasov, P., & Wilkins, E.
- Venue
- Electroanalysis
- Publisher
- Wiley
- Published
- 1997-05
- Volume
- 9
- Issue
- 9
- Pages
- 661-674
- ISSN
- 1040-0397 (ISSN-L)
- 1521-4109
- OpenAlex
- W1973816733
- Cited by
- 440
- References
- 44
- FWCI
- 12.57
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.