CoChat

Design of a Stable Charge Transfer Complex Electrode for a Third-Generation Amperometric Glucose Sensor

Khan, Golam Faruque, Ohwa, Masaki, Wernet, Wolfgang · 1996 · Analytical Chemistry
Cited by 98

The DOI matches its Crossref record.

Abstract

A novel approach to prepare a stable charge transfer complex (CTC) electrode for the direct oxidation of flavoproteins and the fabrication of a third generation amperometric biosensor (Koopal, C.G.J.; Feiters, M.C.; Nolte, R.J.M. Bioelectrochem. Bioenerg. 1992, 29, 159-175) system is described. Tetrathiafulvalene-tetracyanoquinodimethane (TTF-TCNQ), an organic CTC, is grown at the surface of a shapable electroconductive (SEC) film (a polyanion-doped polypyrrole film) in such a way that it makes a tree-shaped crystal structure standing vertically on the surface. Glucose oxidase (GOx) is adsorbed and cross-linked with glutaraldehyde to fix at the surface of the CTC structure. The space between crystals is filled with cross-linked gelatin to ensure the stability of the treelike crystal structure as well as the stability of the enzyme. Because of the close proximity and the favorable orientation of the enzyme at the CTC surface, the enzyme is directly oxidized at the crystal surface, which leads to a glucose sensor with remarkably improved performance. It works at a potential from 0.0 to 0.25 V (vs Ag/AgCl). The maximum current density at 0.25 V reaches 1.8 mA/cm2, with an extended linear range. The oxygen in the normal buffer solution has little effect on the sensor output. The current caused by interference contained in the physiological fluids is negligible. The working life as well as the shelf life of the sensor is substantially prolonged. The sensor was continuously used in a flow injection system with a continuous polarization at 0.1 V, and the samples (usually 10 mM glucose) were injected at 30 min intervals. After 100 days of continuous use, the current output dropped to 40% of the initial level. No change in the output of the sensor was observed over a year when the sensor was stored dry in a freezer. The electrochemical rate constants and the effective Michaelis constant of the system are reported.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/ac9510393

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 98

Metadata

Authors
Khan, G. F., Ohwa, M., & Wernet, W.
Venue
Analytical Chemistry
Published
1996-09-01
Volume
68
Issue
17
Pages
2939-2945
ISSN
  • 0003-2700 (ISSN-L)
  • 1520-6882
OpenAlex
W2035096547
Cited by
98
References
0
FWCI
5.34
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Design of a Stable Charge Transfer Complex Electrode for a Third-Generation Amperometric Glucose Sensor. https://app.cochat.ai/papers/10.1021/ac9510393
The paper
Khan, G. F., Ohwa, M., & Wernet, W. (1996). Design of a Stable Charge Transfer Complex Electrode for a Third-Generation Amperometric Glucose Sensor. Analytical Chemistry. https://doi.org/10.1021/ac9510393

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.