The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Advances in electrochemical immunosensors
Abstract
The developments in the field of electrochemical immunosensors and immunoassays are reviewed. The enzyme labels suitable for amperometric, potentiometric and conductimetric detection are mentioned. Indirect immunosensors (i.e., that involving enzymatic or electroactive labels) use either heterogeneous or homogeneous formats. Immunoelectrodes are based on conventional electrodes, semiconductor devices are represented by ISFETs and light addressable potentiometric sensors (LAPS). Direct label‐free monitoring of immunoreactions is demonstrated on capacitance systems and pulsed detection using polypyrrole‐modified electrodes. The approaches to regeneration of sensing surfaces are discussed. Examples are given on applications of electrochemical immunodevices in clinical medicine and in environmental monitoring.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Development of an Ion-Sensitive Solid-State Device for Neurophysiological Measurements
Bergveld, P. (1970) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1970.4502688 · Cited by 2,134
Cited by
Wearable Chemical Sensors: Present Challenges and Future Prospects
Bandodkar, A. J., Jeerapan, I., & Wang, J. (2016) · ACS Sensors · doi:10.1021/acssensors.6b00250 · Cited by 778
Recent advances in biologically sensitive field-effect transistors (BioFETs)
Schöning, M. J., & Poghossian, A. (2002) · The Analyst · doi:10.1039/b204444g · Cited by 566
Electrochemical Biosensor Applications of Polysaccharides Chitin and Chitosan
Suginta, W., Khunkaewla, P., & Schulte, A. (2013) · Chemical Reviews · doi:10.1021/cr300325r · Cited by 521
Nanomaterials for bio-functionalized electrodes: recent trends
Walcarius, A., Minteer, S. D., Wang, J., Lin, Y., & Merkoçi, A. (2013) · Journal of Materials Chemistry B · doi:10.1039/c3tb20881h · Cited by 366
The Role of Electrochemical Immunosensors in Clinical Analysis
Mollarasouli, F., Kurbanoglu, S., & Ozkan, S. A. (2019) · Biosensors · doi:10.3390/bios9030086 · Cited by 293
Metadata
- Authors
- Skládal, P.
- Venue
- Electroanalysis
- Publisher
- Wiley
- Published
- 1997-06
- Volume
- 9
- Issue
- 10
- Pages
- 737-745
- ISSN
- 1040-0397 (ISSN-L)
- 1521-4109
- OpenAlex
- W2018625690
- Cited by
- 191
- References
- 1
- FWCI
- 13.57
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Advances in electrochemical immunosensors. https://app.cochat.ai/papers/10.1002/elan.1140091002
- The paper
- Skládal, P. (1997). Advances in electrochemical immunosensors. Electroanalysis. https://doi.org/10.1002/elan.1140091002
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.