The DOI matches its Crossref record; 67 of the 67 references it cites were found in a registry or an index.
Potentiometric Ion Sensors Based on Conducting Polymers
Open accessAbstract
Conducting polymers (electroactive conjugated polymers, ECPs) have emerged as one of the most promising transducers for chemical sensors. This is related to the unique electrical, electrochemical and optical properties of conjugated polymers that can be used to convert chemical information (concentration, activity, partial pressure) into electrical or optical signals in the solid state. Application of conjugated polymers in potentiometric ion sensors (ion‐selective electrodes, ISEs) is reviewed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Supramolecular Chemistry: Concepts and Perspectives
Lehn, J. (1995) · Wiley eBooks · doi:10.1002/3527607439 · Cited by 9,864
Handbook of conducting polymers
Skotheim, T. A., Elsenbaumer, R. L., & Reynolds, J. R. (1986) · M. Dekker eBooks · Cited by 8,079
Synthesis of electrically conducting organic polymers: halogen derivatives of polyacetylene, (CH) x
Shirakawa, H., Louis, E. J., MacDiarmid, A. G., Chiang, C. K., & Heeger, A. J. (1977) · Journal of the Chemical Society, Chemical Communications · doi:10.1039/c39770000578 · Cited by 3,867
Conjugated Polymer-Based Chemical Sensors
McQuade, D. T., Pullen, A. E., & Swager, T. M. (2000) · Chemical Reviews · doi:10.1021/cr9801014 · Cited by 3,718
High-Resolution Inkjet Printing of All-Polymer Transistor Circuits
Sirringhaus, H., Kawase, T., Friend, R. H., Shimoda, T., Inbasekaran, M., Wu, W., & Woo, E. P. (2000) · Science · doi:10.1126/science.290.5499.2123 · Cited by 3,311
Handbook of organic conductive molecules and polymers
Nalwa, H. S. (1997) · Cited by 2,786
Carrier-Based Ion-Selective Electrodes and Bulk Optodes. 1. General Characteristics
Bakker, E., Bühlmann, P., & Pretsch, E. (1997) · Chemical Reviews · doi:10.1021/cr940394a · Cited by 2,369
Handbook of advanced electronic and photonic materials and devices
Nalwa, H. S. (2001) · Cited by 1,220
The Molecular Wire Approach to Sensory Signal Amplification
Swager, T. M. (1998) · Accounts of Chemical Research · doi:10.1021/ar9600502 · Cited by 1,139
Paul, E. W., Ricco, A. J., & Wrighton, M. S. (1985) · The Journal of Physical Chemistry · doi:10.1021/j100254a028 · Cited by 1,026
Synthetic metals: a novel role for organic polymers
MacDiarmid, A. G. (2001) · Synthetic Metals · doi:10.1016/s0379-6779(01)00508-2 · Cited by 754
Electron and proton conducting polymers: recent developments and prospects
Inzelt, G., Pineri, M., Schultze, J. W., & Vorotyntsev, M. A. (2000) · Electrochimica Acta · doi:10.1016/s0013-4686(00)00329-7 · Cited by 715
Bobacka, J. (1999) · Analytical Chemistry · doi:10.1021/ac990497z · Cited by 686
Self-citationBakker, E., & Telting-Diaz, M. (2002) · Analytical Chemistry · doi:10.1021/ac0202278 · Cited by 662
Cattrall, R. W. (1997) · Cited by 622
Protein-modified electrodes. The glucose oxidase/polypyrrole system
Umana, M., & Waller, J. (1986) · Analytical Chemistry · doi:10.1021/ac00127a018 · Cited by 588
Foulds, N. C., & Lowe, C. R. (1986) · Journal of the Chemical Society, Faraday Transactions 1: Physical Chemistry in Condensed Phases · doi:10.1039/f19868201259 · Cited by 532
A review of the immobilization of enzymes in electropolymerized films
Barlett, P. N., & Cooper, J. M. (1993) · Journal of Electroanalytical Chemistry · doi:10.1016/0022-0728(93)80001-x · Cited by 472
Fibbioli, M., Morf, W. E., Badertscher, M., de Rooij, N. F., & Pretsch, E. (2000) · Electroanalysis · doi:10.1002/1521-4109(200011)12:16<1286::aid-elan1286>3.0.co;2-q · Cited by 443
Cadogan, A., Gao, Z., Lewenstam, A., Ivaska, A., & Diamond, D. (1992) · Analytical Chemistry · doi:10.1021/ac00045a007 · Cited by 428
Self-citationSemiconducting and metallic polymers: the fourth generation of polymeric materials
Heeger, A. J. (2001) · Synthetic Metals · doi:10.1016/s0379-6779(01)00509-4 · Cited by 415
Coated wire ion-selective electrodes
Cattrall, R. W., & Freiser, H. (1971) · Analytical Chemistry · doi:10.1021/ac60307a032 · Cited by 387
Janata, J., Josowicz, M., Vanýsek, P., & DeVaney, D. M. (1998) · Analytical Chemistry · doi:10.1021/a1980010w · Cited by 330
Marsella, M. J., & Swager, T. M. (1993) · Journal of the American Chemical Society · doi:10.1021/ja00078a090 · Cited by 302
Timed release of chemicals from polypyrrole films
Zinger, B., & Miller, L. L. (1984) · Journal of the American Chemical Society · doi:10.1021/ja00334a076 · Cited by 291
Electroanalysis with Pure, Chemically Modified and Sol-Gel-Derived Silica-Based Materials
Walcarius, A. (2001) · Electroanalysis · doi:10.1002/1521-4109(200105)13:8/9<723::aid-elan723>3.0.co;2-r · Cited by 223
Electroactive Polymer Electrochemistry
(1994) · Springer eBooks · doi:10.1007/978-1-4757-5070-6 · Cited by 202
Single-piece all-solid-state ion-selective electrode
Bobacka, J., Lindfors, T., McCarrick, M., Ivaska, A., & Lewenstam, A. (1995) · Analytical Chemistry · doi:10.1021/ac00116a034 · Cited by 188
Self-citationBobacka, J., McCarrick, M., Lewenstam, A., & Ivaska, A. (1994) · The Analyst · doi:10.1039/an9941901985 · Cited by 175
Self-citationPROCESSIBLE POLYANILINE AS AN ADVANCED POTENTIOMETRIC pH TRANSDUCER. APPLICATION TO BIOSENSORS
Karyakin, A. A., Vuki, M., Lukachova, L. V., Karyakina, E. E., Orlov, A. V., Karpachova, G. P., & Wang, J. (1999) · Analytical Chemistry · doi:10.1021/ac981337a · Cited by 159
Vázquez, M., Bobacka, J., Ivaska, A. U., & Lewenstam, A. (2002) · Sensors and Actuators B Chemical · doi:10.1016/s0925-4005(01)00983-2 · Cited by 148
Self-citationToward intelligent polymers: DNA sensors based on oligonucleotide-functionalized polypyrroles
Garnier, F., Korri‐Youssoufi, H., Srivastava, P., Mandrand, B., & Delair, T. (1999) · Synthetic Metals · doi:10.1016/s0379-6779(98)00169-6 · Cited by 145
Functionalized Conducting Polymers—Towards Intelligent Materials
Garnier, F. (1989) · Angewandte Chemie International Edition in English · doi:10.1002/anie.198905131 · Cited by 138
Zhang, X., Ogorevc, B., & Wang, J. (2002) · Analytica Chimica Acta · doi:10.1016/s0003-2670(01)01435-0 · Cited by 128
Hydrogen ion selective microelectrode prepared by modifying an electrode with polymers
Oyama, N., Hirokawa, T., Yamaguchi, S., Ushizawa, N., & Shimomura, T. (1987) · Analytical Chemistry · doi:10.1021/ac00129a009 · Cited by 120
Mechanism of ionic and redox sensitivity of p-type conducting polymers
Bobacka, J., Gao, Z., Ivaska, A. U., & Lewenstam, A. (1994) · Journal of Electroanalytical Chemistry · doi:10.1016/0022-0728(93)03081-y · Cited by 114
Self-citationRedox-Active Self-Assembled Monolayers for Solid-Contact Polymeric Membrane Ion-Selective Electrodes
Fibbioli, M., Bandyopadhyay, K., Liu, S., Echegoyen, L. A., Enger, O., Diederich, F., Gingery, D., Bühlmann, P., Persson, H. H. J., Suter, U. W., et al. (2002) · Chemistry of Materials · doi:10.1021/cm0109589 · Cited by 114
Covalent electropolymerization of glucose oxidase in polypyrrole
Wolowacz, S. E., Hin, B. F. Y. Y., & Lowe, C. R. (1992) · Analytical Chemistry · doi:10.1021/ac00038a008 · Cited by 109
Mechanism of ionic and redox sensitivity of p-type conducting polymers
Lewenstam, A., Bobacka, J., & Ivaska, A. U. (1994) · Journal of Electroanalytical Chemistry · doi:10.1016/0022-0728(93)03080-9 · Cited by 104
Self-citationAll solid-state hydrogen ion-selective electrode based on a conducting poly(pyrrole) solid contact
Michalska, A., Hulanicki, A., & Lewenstam, A. (1994) · The Analyst · doi:10.1039/an9941902417 · Cited by 101
Self-citationElectrofunctional polymers: their role in the development of new analytical systems
Lewis, T. W., Wallace, G. G., & Smyth, M. R. (1999) · The Analyst · doi:10.1039/a808015a · Cited by 100
Novel polypyrrole based all-solid-state potassium-selective microelectrodes
Gyurcsányi, R. E., Nybäck, A.-S., Ivaska, A. U., Tóth, K., & Nagy, G. (1998) · The Analyst · doi:10.1039/a800389k · Cited by 99
Self-citationHauser, P. C., Chiang, D. W. L., & Wright, G. A. (1995) · Analytica Chimica Acta · doi:10.1016/0003-2670(94)00472-x · Cited by 99
All-solid-state planar miniature ion-selective chloride electrode
Zielińska, R., Mulik, E., Michalska, A., Achmatowicz, S., & Maj‐Żurawska, M. (2002) · Analytica Chimica Acta · doi:10.1016/s0003-2670(01)01407-6 · Cited by 95
Bobacka, J., Ivaska, A. U., & Lewenstam, A. (1999) · Analytica Chimica Acta · doi:10.1016/s0003-2670(98)00667-9 · Cited by 95
Self-citationPerepichka, I. F., Besbes, M., Levillain, E., Sallé, M., & Roncali, J. (2002) · Chemistry of Materials · doi:10.1021/cm010756c · Cited by 89
Potassium ion responsive coated wire electrode based on valinomycin
Cattrall, R. W., Tribuzio, S., & Freiser, H. (1974) · Analytical Chemistry · doi:10.1021/ac60350a026 · Cited by 83
Functionalized Conducting Polymers—Towards Intelligent Materials
Garnier, F. (1989) · Angewandte Chemie · doi:10.1002/ange.19891010447 · Cited by 78
All-Solid-State Potentiometric Sensors for Potassium and Sodium Based on Poly(pyrrole) Solid Contact
Michalska, A., Hulanicki, A., & Lewenstam, A. (1997) · Microchemical Journal · doi:10.1006/mchj.1997.1489 · Cited by 74
Self-citationPolyindole modified potassium ion-sensor using dibenzo-18-crown-6 mediated PVC matrix membrane
Pandey, P. C., & Prakash, R. (1998) · Sensors and Actuators B Chemical · doi:10.1016/s0925-4005(97)00332-8 · Cited by 74
Lindfors, T., & Ivaska, A. U. (2001) · Analytica Chimica Acta · doi:10.1016/s0003-2670(01)00996-5 · Cited by 67
Self-citationAnionic responses of electrochemically synthesized polypyrrole films
Cadogan, A. (1992) · Talanta · doi:10.1016/0039-9140(92)80070-t · Cited by 64
Bobacka, J., Lewenstam, A., & Ivaska, A. U. (2001) · Journal of Electroanalytical Chemistry · doi:10.1016/s0022-0728(00)00515-5 · Cited by 62
Self-citationPotentiometric pCO2 sensor using polyaniline-coated pH-sensitive electrodes
Cui, G., Lee, J. S., Kim, S. J., Nam, H., Cha, G. S., & Kim, H. D. (1998) · The Analyst · doi:10.1039/a802872i · Cited by 53
All‐solid‐state chloride‐selective electrode with poly(pyrrole) solid contact
Hulanicki, A., & Michalska, A. (1995) · Electroanalysis · doi:10.1002/elan.1140070718 · Cited by 53
Kosminsky, L., & Bertotti, M. (1999) · Electroanalysis · doi:10.1002/(sici)1521-4109(199907)11:9<647::aid-elan647>3.0.co;2-n · Cited by 52
A novel paper pH sensor based on polypyrrole
Fang, Y., Ngin, T. S., & Hailin, G. (1996) · Sensors and Actuators B Chemical · doi:10.1016/0925-4005(96)80106-7 · Cited by 49
Trojanowicz, M., Lewenstam, A., Krawczyk, T. K. V., Lähdesmäki, I., & Szczepek, W. J. (1996) · Electroanalysis · doi:10.1002/elan.1140080307 · Cited by 47
Self-citationBobacka, J., Lewenstam, A., & Ivaska, A. U. (1993) · Talanta · doi:10.1016/0039-9140(93)80223-e · Cited by 43
Self-citationLindfors, T., Bobacka, J., Lewenstam, A., & Ivaska, A. U. (1996) · The Analyst · doi:10.1039/an9962101823 · Cited by 36
Self-citationKomaba, S., Arakawa, J., Seyama, M., Ōsaka, T., Satoh, I., & NAKAMURA, S. (1998) · Talanta · doi:10.1016/s0039-9140(97)00396-2 · Cited by 34
Lindfors, T., & Ivaska, A. U. (2000) · Analytica Chimica Acta · doi:10.1016/s0003-2670(99)00687-x · Cited by 34
Self-citationCharacterization of biosensors based on membranes containing a conducting polymer
Battilotti, M., Colapicchioni, C., Giannini, I., Porcelli, F., Campanella, L., Cordatore, M., Mazzei, F., & TOMASSETTI, M. (1989) · Analytica Chimica Acta · doi:10.1016/s0003-2670(00)81949-2 · Cited by 31
On the nature of the potentiometric response of polypyrrole in acidic solutions
Michalska, A., Maksymiuk, K., & Hulanicki, A. (1995) · Journal of Electroanalytical Chemistry · doi:10.1016/0022-0728(95)03996-t · Cited by 30
Momma, T., Yamamoto, M., Komaba, S., & Ōsaka, T. (1996) · Journal of Electroanalytical Chemistry · doi:10.1016/0022-0728(95)04459-0 · Cited by 27
Ion-selective conductometric microsensors based on the phenomenon of specific salt extraction
Shulga, A., Ahlers, B., & Cammann, K. (1995) · Journal of Electroanalytical Chemistry · doi:10.1016/0022-0728(95)04205-3 · Cited by 20
Ion-Selective Electrodes Based on Bilayer Film Coating
Oyama, N., Ohsaka, T., Yoshimura, F., Mizunuma, M., Yamaguchi, S., Ushizawa, N., & Shimomura, T. (1988) · Journal of Macromolecular Science Part A - Chemistry · doi:10.1080/00222338808053434 · Cited by 17
Cited by
Bobacka, J., Ivaska, A., & Lewenstam, A. (2008) · Chemical Reviews · doi:10.1021/cr068100w · Cited by 975
Self-citationConducting polymers in chemical sensors and arrays
Lange, U., Roznyatovskaya, N. V., & Mirsky, V. M. (2008) · Analytica Chimica Acta · doi:10.1016/j.aca.2008.02.068 · Cited by 911
Combinatorial and High-Throughput Screening of Materials Libraries: Review of State of the Art
Potyrailo, R., Rajan, K., Stoewe, K., Takeuchi, I., Chisholm, B., & Lam, H. (2011) · ACS Combinatorial Science · doi:10.1021/co200007w · Cited by 511
Shao, Y., Ying, Y., & Ping, J. (2020) · Chemical Society Reviews · doi:10.1039/c9cs00587k · Cited by 472
Conducting Polymer‐Based Solid‐State Ion‐Selective Electrodes
Bobacka, J. (2006) · Electroanalysis · doi:10.1002/elan.200503384 · Cited by 418
Self-citation
Metadata
- Authors
- Bobacka, J., Ivaska, A., & Lewenstam, A.
- Venue
- Electroanalysis
- Publisher
- Wiley
- Published
- 2003-04
- Volume
- 15
- Issue
- 5-6
- Pages
- 366-374
- ISSN
- 1040-0397 (ISSN-L)
- 1521-4109
- OpenAlex
- W2094719083
- Cited by
- 277
- References
- 67
- FWCI
- 11.36
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.