Probing Biomolecular Interactions at Conductive and Semiconductive Surfaces by Impedance Spectroscopy: Routes to Impedimetric Immunosensors, DNA‐Sensors, and Enzyme Biosensors
Abstract
Impedance spectroscopy is a rapidly developing electrochemical technique for the characterization of biomaterial‐functionalized electrodes and biocatalytic transformations at electrode surfaces, and specifically for the transduction of biosensing events at electrodes or field‐effect transistor devices. The immobilization of biomaterials, e.g., enzymes, antigens/antibodies or DNA on electrodes or semiconductor surfaces alters the capacitance and interfacial electron transfer resistance of the conductive or semiconductive electrodes. Impedance spectroscopy allows analysis of interfacial changes originating from biorecognition events at electrode surfaces. Kinetics and mechanisms of electron transfer processes corresponding to biocatalytic reactions occurring at modified electrodes can be also derived from Faradaic impedance spectroscopy. Different immunosensors that use impedance measurements for the transduction of antigen‐antibody complex formation on electronic transducers were developed. Similarly, DNA biosensors using impedance measurements as readout signals were developed. Amplified detection of the analyte DNA using Faradaic impedance spectroscopy was accomplished by the coupling of functionalized liposomes or by the association of biocatalytic conjugates to the sensing interface providing biocatalyzed precipitation of an insoluble product on the electrodes. The amplified detections of viral DNA and single‐base mismatches in DNA were accomplished by similar methods. The changes of interfacial features of gate surfaces of field‐effect transistors (FET) upon the formation of antigen‐antibody complexes or assembly of protein arrays were probed by impedance measurements and specifically by transconductance measurements. Impedance spectroscopy was also applied to characterize enzyme‐based biosensors. The reconstitution of apo‐enzymes on cofactor‐functionalized electrodes and the formation of cofactor‐enzyme affinity complexes on electrodes were probed by Faradaic impedance spectroscopy. Also biocatalyzed reactions occurring on electrode surfaces were analyzed by impedance spectroscopy. The theoretical background of the different methods and their practical applications in analytical procedures were outlined in this article.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Electrochemical Methods: Fundamentals and Applications
Bard, A. J., & Faulkner, L. R. (1980) · Cited by 22,822
Kinetics of rapid electrode reactions
Randles, J. E. B. (1947) · Discussions of the Faraday Society · doi:10.1039/df9470100011 · Cited by 1,884
Integration of Layered Redox Proteins and Conductive Supports for Bioelectronic Applications
Willner, I., & Katz, E. (2000) · Angewandte Chemie International Edition · doi:10.1002/(sici)1521-3773(20000403)39:7<1180::aid-anie1180>3.0.co;2-e · Cited by 950
Self-citationElectrical wiring of redox enzymes
Heller, A. (1990) · Accounts of Chemical Research · doi:10.1021/ar00173a002 · Cited by 788
SURVEY AND SUMMARY: From DNA biosensors to gene chips
Wang, J. (2000) · Nucleic Acids Research · doi:10.1093/nar/28.16.3011 · Cited by 753
Immunosensors—principles and applications to clinical chemistry
Luppa, P. B., Sokoll, L. J., & Chan, D. W. (2001) · Clinica Chimica Acta · doi:10.1016/s0009-8981(01)00629-5 · Cited by 741
Biosensing with surface plasmon resonance — how it all started
Liedberg, B., Nylander, C., & Lundström, I. (1995) · Biosensors and Bioelectronics · doi:10.1016/0956-5663(95)96965-2 · Cited by 684
Recent advances in biologically sensitive field-effect transistors (BioFETs)
Schöning, M. J., & Poghossian, A. (2002) · The Analyst · doi:10.1039/b204444g · Cited by 566
Sequence-selective biosensor for DNA based on electroactive hybridization indicators
Millan, K. M., & Mikkelsen, S. R. (1993) · Analytical Chemistry · doi:10.1021/ac00065a025 · Cited by 552
Electrochemical DNA Hybridization Biosensors
Gooding, J. J. (2002) · Electroanalysis · doi:10.1002/1521-4109(200209)14:17<1149::aid-elan1149>3.0.co;2-8 · Cited by 480
Nanoscaled interdigitated electrode arrays for biochemical sensors
Van Gerwen, P., Laureyn, W., Laureys, W., Huyberechts, G., Op De Beeck, M., Baert, K., Suls, J., Sansen, W., Jacobs, P., Hermans, L., et al. (1998) · Sensors and Actuators B: Chemical · doi:10.1016/s0925-4005(98)00128-2 · Cited by 391
Willner, I., Heleg-Shabtai, V., Blonder, R., Katz, E., Tao, G., Bückmann, A. F., & Heller, A. (1996) · Journal of the American Chemical Society · doi:10.1021/ja9608611 · Cited by 370
Self-citationDetection of single-base DNA mutations by enzyme-amplified electronic transduction
Patolsky, F., Lichtenstein, A., & Willner, I. (2001) · Nature Biotechnology · doi:10.1038/85704 · Cited by 368
Self-citationPeptide Nucleic Acid Probes for Sequence-Specific DNA Biosensors
Wang, J., Palecek, E., Nielsen, P. E., Rivas, G., Cai, X., Shiraishi, H., Dontha, N., Luo, D., & Farias, P. A. M. (1996) · Journal of the American Chemical Society · doi:10.1021/ja9608050 · Cited by 353
Direct Detection of the Hybridization of Synthetic Homo-Oligomer DNA Sequences by Field Effect
Souteyrand, E., Cloarec, J. P., Martin, J. R., Wilson, C., Lawrence, I., Mikkelsen, S., & Lawrence, M. F. (1997) · The Journal of Physical Chemistry B · doi:10.1021/jp963056h · Cited by 340
Surface Plasmon Resonance-Based Immunoassays
Mullett, W. M., Lai, E. P. C., & Yeung, J. M. (2000) · Methods · doi:10.1006/meth.2000.1039 · Cited by 322
Biomaterials for Sensors, Fuel Cells, and Circuitry
Willner, I. (2002) · Science · doi:10.1126/science.298.5602.2407 · Cited by 312
Self-citationProtein absorption and ellipsometry in biomaterial research
Elwing, H. (1998) · Biomaterials · doi:10.1016/s0142-9612(97)00112-9 · Cited by 298
Electrochecmical biosensors for DNA sequence detection
Mikkelsen, S. R. (1996) · Electroanalysis · doi:10.1002/elan.1140080104 · Cited by 293
Mirsky, V. M., Riepl, M., & Wolfbeis, O. S. (1997) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(97)00053-5 · Cited by 289
Raitman, O. A., Katz, E., Bückmann, A. F., & Willner, I. (2002) · Journal of the American Chemical Society · doi:10.1021/ja012680r · Cited by 263
Self-citationPatolsky, F., Lichtenstein, A., & Willner, I. (2001) · Journal of the American Chemical Society · doi:10.1021/ja0036256 · Cited by 250
Self-citationPei, R., Cheng, Z., Wang, E., & Yang, X. (2001) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(01)00150-6 · Cited by 249
Patolsky, F., Zayats, M., Katz, E., & Willner, I. (1999) · Analytical Chemistry · doi:10.1021/ac9901541 · Cited by 234
Self-citationApplication of Electrochemical Biosensors for Detection of Food Pathogenic Bacteria
Ivnitski, D. M., Abdel‐Hamid, I., Atanasov, P., Wilkins, E. S., & Stricker, S. A. (2000) · Electroanalysis · doi:10.1002/(sici)1521-4109(20000301)12:5<317::aid-elan317>3.0.co;2-a · Cited by 223
Jordan, C. E., & Corn, R. M. (1997) · Analytical Chemistry · doi:10.1021/ac961012z · Cited by 216
Transducer aspects of biosensors
Sethi, R. S. (1994) · Biosensors and Bioelectronics · doi:10.1016/0956-5663(94)80127-4 · Cited by 195
Patolsky, F., Katz, E., Bardea, A., & Willner, I. (1999) · Langmuir · doi:10.1021/la981682v · Cited by 191
Self-citationPrinciples of Affinity-Based Biosensors
Rogers, K. R. (2000) · Molecular Biotechnology · doi:10.1385/mb:14:2:109 · Cited by 191
Enzyme monolayer-functionalized field-effect transistors for biosensor applications
Kharitonov, A. B., Zayats, M., Lichtenstein, A., Katz, E., & Willner, I. (2000) · Sensors and Actuators B: Chemical · doi:10.1016/s0925-4005(00)00573-6 · Cited by 190
Self-citationKatz, E. Y., Schlereth, D. D., & Schmidt, H. (1994) · Journal of Electroanalytical Chemistry · doi:10.1016/0022-0728(93)03010-m · Cited by 179
Self-citationA critical evaluation of direct electrical protein detection methods
Bergveld, P. (1991) · Biosensors and Bioelectronics · doi:10.1016/0956-5663(91)85009-l · Cited by 175
Genosensor technology and the detention of interfacial nucleic acid chemistry
Yang, M., McGovern, M. E., & Thompson, M. (1997) · Analytica Chimica Acta · doi:10.1016/s0003-2670(97)90055-6 · Cited by 165
Sallacan, N., Zayats, M., Bourenko, T., Kharitonov, A. B., & Willner, I. (2002) · Analytical Chemistry · doi:10.1021/ac0109873 · Cited by 150
Self-citationAlfonta, L., Willner, I., Throckmorton, D. J., & Singh, A. K. (2001) · Analytical Chemistry · doi:10.1021/ac010542e · Cited by 144
Self-citationNahir, T. M., & Bowden, E. F. (1996) · Journal of Electroanalytical Chemistry · doi:10.1016/0022-0728(96)04551-2 · Cited by 143
Patolsky, F., Katz, E. Y., & Willner, I. (2002) · Angewandte Chemie International Edition · doi:10.1002/1521-3773(20020916)41:18<3398::aid-anie3398>3.0.co;2-w · Cited by 137
Self-citationEnzyme-Amplified Amperometric Sandwich Test for RNA and DNA
Campbell, C. N., Gal, D., Cristler, N., Banditrat, C., & Heller, A. (2001) · Analytical Chemistry · doi:10.1021/ac015602v · Cited by 135
Pei, R., Cui, X., Yang, X., & Wang, E. (2001) · Biomacromolecules · doi:10.1021/bm0001289 · Cited by 132
Interface analysis in biosensor design
Göpel†, W., & Heiduschka, P. (1995) · Biosensors and Bioelectronics · doi:10.1016/0956-5663(95)99225-a · Cited by 123
Monitoring Motility, Spreading, and Mortality of Adherent Insect Cells Using an Impedance Sensor
Luong, J. H. T., Habibi-Rezaei, M., Meghrous, J., Xiao, C., Male, K. B., & Kamen, A. (2001) · Analytical Chemistry · doi:10.1021/ac0011585 · Cited by 115
Ong, K. G., Wang, J., Singh, R., Bachas, L. G., & Grimes, C. A. (2001) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(01)00131-2 · Cited by 107
Impedimetric immunosensor using avidin–biotin for antibody immobilization
Ouerghi, O., Touhami, A., Jaffrezic-Renault, N. J., Martelet, C., Ouada, H. B., & Cosnier, S. (2002) · Bioelectrochemistry · doi:10.1016/s1567-5394(02)00029-4 · Cited by 104
Electrochemical impedance spectroscopy as a platform for reagentless bioaffinity sensing
Lillie, G. C., Payne, P. A., & Vadgama, P. M. (2001) · Sensors and Actuators B Chemical · doi:10.1016/s0925-4005(01)00821-8 · Cited by 100
Kharitonov, A. B., Wasserman, J., Katz, E. Y., & Willner, I. (2001) · The Journal of Physical Chemistry B · doi:10.1021/jp0045383 · Cited by 89
Self-citationPiezoelectric Immunosensors - Theory and Applications
O’Sullivan, C. K., Vaughan, R. D., & Guilbault, G. G. (1999) · Analytical Letters · doi:10.1080/00032719908542975 · Cited by 85
On the impedance of the silicon dioxide/electrolyte interface
Bousse, L. J., & Bergveld, P. (1983) · Journal of Electroanalytical Chemistry · doi:10.1016/s0022-0728(83)80030-8 · Cited by 80
pH dependence of the Si/SiO2 interface state density for EOS systems
Diot, J.-L., Joseph, J., Martin, J. R., & Cléchet, P. (1985) · Journal of Electroanalytical Chemistry · doi:10.1016/0022-0728(85)85053-1 · Cited by 78
Immobilized xanthine oxidase chemically modified electrode as a dual analytical sensor
Ianniello, R. M., Lindsay, T. J., & Yacynych, A. M. (1982) · Analytical Chemistry · doi:10.1021/ac00249a015 · Cited by 78
3D-biohybrid systems: applications in drug screening
Reininger-Mack, A., Thielecke, H., & Robitzki, A. A. (2002) · Trends in biotechnology · doi:10.1016/s0167-7799(01)01880-7 · Cited by 73
Cloarec, J., Deligianis, N., Martin, J. R., Lawrence, I., Souteyrand, É., Polychronakos, C., & Lawrence, M. F. (2002) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(01)00282-2 · Cited by 72
Nishi, N. (2019) · Review of Polarography · doi:10.5189/revpolarography.65.87 · Cited by 71
Saum, A. G. E., Cumming, R. H., & Rowell, F. J. (1998) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(97)00129-2 · Cited by 62
Raitman, O. A., Patolsky, F., Katz, E. Y., & Willner, I. (2002) · Chemical Communications · doi:10.1039/b205393d · Cited by 61
Self-citationZayats, M., Kharitonov, A. B., Katz, E. Y., Bückmann, A. F., & Willner, I. (2000) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(00)00120-2 · Cited by 60
Self-citationFunctionalization of Si/SiO2 substrates with homooligonucleotides for a DNA biosensor
Cloarec, J., Martin, J. R., Polychronakos, C., Lawrence, I., Lawrence, M. F., & Souteyrand, É. (1999) · Sensors and Actuators B Chemical · doi:10.1016/s0925-4005(99)00102-1 · Cited by 51
Enzyme-Modulated Cleavage of dsDNA for Studying Interfacial Biomolecular Interactions
Yan, F., & Sadik, O. A. (2001) · Journal of the American Chemical Society · doi:10.1021/ja005719l · Cited by 48
Membrane Characterization of Anion-Selective CHEMFETs by Impedance Spectroscopy
Antonisse, M. M. G., Snellink‐Ruël, B. H. M., Lugtenberg, R. J. W., Engbersen, J. F. J., van den Berg, A., & Reinhoudt, D. N. (1999) · Analytical Chemistry · doi:10.1021/ac990721k · Cited by 47
Nucleic Acid-Promoted Electron Transfer to Cytochrome c
Lisdat, F., Ge, B., Krause, B., Ehrlich, A., Bienert, H., & Scheller, F. W. (2001) · Electroanalysis · doi:10.1002/1521-4109(200110)13:15 · Cited by 38
The preparation of CHEMFET selective gates by thin silica layer grafting and their behaviour
Bataillard, P., Cléchet, P., Jaffrezic-Renault, N. J., Kong, X. G., & Martelet, C. (1987) · Sensors and Actuators · doi:10.1016/0250-6874(87)80038-0 · Cited by 35
Monitoring of ISFET encapsulation aging by impedance measurements
Chovelon, J., Jaffrezic-Renault, N. J., Cros, Y., Fombon, J. J., & Pedone, D. (1991) · Sensors and Actuators B Chemical · doi:10.1016/0925-4005(91)85006-5 · Cited by 30
Surfactant bilayers for the direct electrochemical detection of affinity interactions
Vagin, M. Y., Karyakin, A. A., & Hianik, T. (2002) · Bioelectrochemistry · doi:10.1016/s1567-5394(01)00142-6 · Cited by 29
Souteyrand, É., Chen, C., Cloarec, J., Nesme, X., Simonet, P., Navarro, I., & Martin, J. R. (2000) · Applied Biochemistry and Biotechnology · doi:10.1385/abab:89:2-3:195 · Cited by 23
Characterising an insect antenna as a receptor for a biosensor by means of impedance spectroscopy
Schroth, P., Luth, H., Hummel, H. E., Schütz, S., & Schöning, M. J. (2001) · Electrochimica Acta · doi:10.1016/s0013-4686(01)00568-0 · Cited by 13
ANALYSIS OF IMPORTANT FRESHWATER AND MARINE TOXINS
Pravda, M., Kreuzer, M. P., & Guilbault, G. G. (2002) · Analytical Letters · doi:10.1081/al-120002357 · Cited by 12
Cited by
Synthetic Molecular Motors and Mechanical Machines
Kay, E. R., Leigh, D. A., & Zerbetto, F. (2007) · Angewandte Chemie International Edition · doi:10.1002/anie.200504313 · Cited by 2,609
Wan, T. H., Saccoccio, M., Chen, C., & Ciucci, F. (2015) · Electrochimica Acta · doi:10.1016/j.electacta.2015.09.097 · Cited by 2,505
Electrochemical Biosensors - Sensor Principles and Architectures
Grieshaber, D., MacKenzie, R., Vörös, J., & Reimhult, E. (2008) · Sensors · doi:10.3390/s80314000 · Cited by 2,329
Functional Nucleic Acid Sensors
Liu, J., Cao, Z., & Lu, Y. (2009) · Chemical Reviews · doi:10.1021/cr030183i · Cited by 2,187
Erbas-Cakmak, S., Leigh, D. A., McTernan, C. T., & Nussbaumer, A. L. (2015) · Chemical Reviews · doi:10.1021/acs.chemrev.5b00146 · Cited by 1,982
Metadata
- Authors
- Katz, E., & Willner, I.
- Venue
- Electroanalysis
- Publisher
- Wiley
- Published
- 2003-07
- Volume
- 15
- Issue
- 11
- Pages
- 913-947
- ISSN
- 1040-0397 (ISSN-L)
- 1521-4109
- OpenAlex
- W2120890726
- Cited by
- 1,351
- References
- 65
- FWCI
- 43.24
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.