The DOI matches its Crossref record; 28 of the 28 references it cites were found in a registry or an index.
Achieving Direct Electrical Connection to Glucose Oxidase Using Aligned Single Walled Carbon Nanotube Arrays
Abstract
Direct electron transfer between an electrode and the redox active centre of glucose oxidase, flavin adenine dinucleotide (FAD), is probed using carbon nanotube modified gold electrodes. Gold electrodes are first modified with a self‐assembled monolayer of cysteamine and then shortened single walled carbon nanotubes (SWNT) are aligned normal to the electrode surface by self‐assembly. The electrochemistry of these aligned nanotube electrode arrays is initially investigated using potassium ferricyanide which showed SWNT act as nanoelectrodes with the ends of the tubes more electrochemically active than the walls. Subsequently the nanotubes are plugged into the enzymes in one of two ways. In the first method, native glucose oxidase is covalently attached to the ends of the aligned tubes which allowed close approach to FAD and direct electron transfer to be observed with a rate constant of 0.3 s−1. In the second strategy, FAD was attached to the ends of the tubes and the enzyme reconstituted around the surface immobilized FAD. This latter approach allowed more efficient electron transfer to the FAD with a rate constant of 9 s−1.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Laviron, E. (1979) · Journal of Electroanalytical Chemistry and Interfacial Electrochemistry · doi:10.1016/s0022-0728(79)80075-3 · Cited by 7,234
Liu, J., Rinzler, A. G., Dai, H., Hafner, J. H., Bradley, R. K., Boul, P. J., Lu, A., Iverson, T., Shelimov, K., Huffman, C. B., et al. (1998) · Science · doi:10.1126/science.280.5367.1253 · Cited by 2,903
Self-citationSolubilization of Carbon Nanotubes by Nafion toward the Preparation of Amperometric Biosensors
Wang, J., Musameh, M., & Lin, Y. (2003) · Journal of the American Chemical Society · doi:10.1021/ja028951v · Cited by 1,382
Glucose oxidase: an ideal enzyme
Wilson, R., & Turner, A. P. F. (1992) · Biosensors and Bioelectronics · doi:10.1016/0956-5663(92)87013-f · Cited by 1,350
"Plugging into Enzymes": Nanowiring of Redox Enzymes by a Gold Nanoparticle
Xiao, Y., Patolsky, F., Katz, E., Hainfeld, J. F., & Willner, I. (2003) · Science · doi:10.1126/science.1080664 · Cited by 1,270
Protein Electrochemistry Using Aligned Carbon Nanotube Arrays
Gooding, J. J., Wibowo, R., Liu, Yang, W., Losic, D., Orbons, S., Mearns, F. J., Shapter, J. G., & Hibbert, D. B. (2003) · Journal of the American Chemical Society · doi:10.1021/ja035722f · Cited by 881
Self-citationElectrical wiring of redox enzymes
Heller, A. (1990) · Accounts of Chemical Research · doi:10.1021/ar00173a002 · Cited by 788
Direct electron transfer of glucose oxidase on carbon nanotubes
Guiseppi-Elie, A., Lei, C., & Baughman, R. H. (2002) · Nanotechnology · doi:10.1088/0957-4484/13/5/303 · Cited by 629
Electrochemical Sensors Based on Carbon Nanotubes
Zhao, Q., Gan, Z., & Zhuang, Q. (2002) · Electroanalysis · doi:10.1002/elan.200290000 · Cited by 622
Long‐Range Electrical Contacting of Redox Enzymes by SWCNT Connectors
Patolsky, F., Weizmann, Y., & Willner, I. (2004) · Angewandte Chemie International Edition · doi:10.1002/anie.200353275 · Cited by 609
Degani, Y., & Heller, A. (1987) · The Journal of Physical Chemistry · doi:10.1021/j100290a001 · Cited by 574
Carbon Nanotube Purification: Preparation and Characterization of Carbon Nanotube Paste Electrodes
Valentini, F., Amine, A., Orlanducci, S., Terranova, M. L., & Palleschi, G. (2003) · Analytical Chemistry · doi:10.1021/ac0300237 · Cited by 540
Fast Electron Transfer Kinetics on Multiwalled Carbon Nanotube Microbundle Electrodes
Nugent, J. M., Santhanam, K. S. V., Rubio, Á., & Ajayan, P. M. (2001) · Nano Letters · doi:10.1021/nl005521z · Cited by 510
Balavoine, F., Schultz, P., Richard, C., Mallouh, V., Ebbesen, T. W., & Mioskowski, C. (1999) · Angewandte Chemie International Edition · doi:10.1002/(sici)1521-3773(19990712)38:13/14<1912::aid-anie1912>3.0.co;2-2 · Cited by 457
Organizing Single-Walled Carbon Nanotubes on Gold Using a Wet Chemical Self-Assembling Technique
Liu, Z., Shen, Z., Zhu, T., Hou, S., Ying, L., Shi, Z., & Gu, Z. (2000) · Langmuir · doi:10.1021/la9914110 · Cited by 401
Ohara, T. J., Rajagopalan, R., & Heller, A. (1994) · Analytical Chemistry · doi:10.1021/ac00087a008 · Cited by 379
Willner, I., Heleg-Shabtai, V., Blonder, R., Katz, E., Tao, G., Bückmann, A. F., & Heller, A. (1996) · Journal of the American Chemical Society · doi:10.1021/ja9608611 · Cited by 370
Novel Three-Dimensional Electrodes: Electrochemical Properties of Carbon Nanotube Ensembles
Li, J., Cassell, A., Delzeit, L., Han, J., & Meyyappan, M. (2002) · The Journal of Physical Chemistry B · doi:10.1021/jp021201n · Cited by 307
Electronic Detection of Nucleic Acids
Umek, R. M., Lin, S. W., Vielmetter, J., Terbrueggen, R. H., Irvine, B., Yu, C. J., Kayyem, J. F., Yowanto, H., Blackburn, G. F., Farkas, D. H., et al. (2001) · The Journal of Molecular Diagnostics · doi:10.1016/s1525-1578(10)60655-1 · Cited by 253
The fabrication and electrochemical characterization of carbon nanotube nanoelectrode arrays
Koehne, J. E., Li, J., Cassell, A. M., Chen, H., Qi, Y., Ng, H. T., Han, J., & Meyyappan, M. (2004) · Journal of Materials Chemistry · doi:10.1039/b311728f · Cited by 248
Koehne, J., Chen, H., Li, J., Cassell, A. M., Ye, Q., Ng, H. T., Han, J., & Meyyappan, M. (2003) · Nanotechnology · doi:10.1088/0957-4484/14/12/001 · Cited by 181
Direct electrochemistry of horseradish peroxidase at carbon nanotube powder microelectrode
Zhao, Y.-D., Zhang, W.-D., Chen, H., Luo, Q.-M., & Li, S. F. Y. (2002) · Sensors and Actuators B: Chemical · doi:10.1016/s0925-4005(02)00232-0 · Cited by 169
Schuhmann, W. (2002) · Reviews in Molecular Biotechnology · doi:10.1016/s1389-0352(01)00058-7 · Cited by 166
Protein-Affinity of Single-Walled Carbon Nanotubes in Water
Lin, Y., Allard, L. F., & Sun, Y. (2004) · The Journal of Physical Chemistry B · doi:10.1021/jp031248o · Cited by 146
Cyclic voltammetry of FAD adsorbed on graphite, glassy carbon, platinum and gold electrodes
Gorton, L., & Johansson, G. (1980) · Journal of Electroanalytical Chemistry · doi:10.1016/s0022-0728(80)80518-3 · Cited by 140
Lötzbeyer, T., Schuhmann, W. W., & Schmidt, H. (1996) · Sensors and Actuators B Chemical · doi:10.1016/0925-4005(96)01834-5 · Cited by 105
Study of carbon nanotubes–HRP modified electrode and its application for novel on-line biosensors
Yamamoto, K., Shi, G., Zhou, T., Xu, F., Xu, J., Kato, T., Jin, J., & Jin, L. (2003) · The Analyst · doi:10.1039/b209698f · Cited by 95
Liu, Paddon‐Row, M. N., & Gooding, J. J. (2004) · The Journal of Physical Chemistry B · doi:10.1021/jp037494h · Cited by 76
Self-citation
Cited by
Electrochemical Glucose Biosensors
Wang, J. (2008) · Chemical Reviews · doi:10.1021/cr068123a · Cited by 3,498
Carbon Nanomaterials in Biosensors: Should You Use Nanotubes or Graphene?
Yang, W., Ratinac, K. R., Ringer, S. P., Thordarson, P., Gooding, J. J., & Braet, F. (2010) · Angewandte Chemie International Edition · doi:10.1002/anie.200903463 · Cited by 1,431
Self-citationElectrochemical non-enzymatic glucose sensors
Park, S., Boo, H., & Chung, T. D. (2006) · Analytica Chimica Acta · doi:10.1016/j.aca.2005.05.080 · Cited by 1,159
Gooding, J. J. (2005) · Electrochimica Acta · doi:10.1016/j.electacta.2004.08.052 · Cited by 1,060
Self-citationBiosensors based on carbon nanotubes
Balasubramanian, K., & Burghard, M. (2006) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-006-0314-8 · Cited by 727
Metadata
- Authors
- Liu, J., Chou, A., Rahmat, W., Paddon‐Row, M. N., & Gooding, J. J.
- Venue
- Electroanalysis
- Publisher
- Wiley
- Published
- 2005-01
- Volume
- 17
- Issue
- 1
- Pages
- 38-46
- ISSN
- 1040-0397 (ISSN-L)
- 1521-4109
- OpenAlex
- W2088365189
- Cited by
- 307
- References
- 28
- FWCI
- 16.02
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.