The DOI matches its Crossref record; 28 of the 28 references it cites were found in a registry or an index.
Achieving Direct Electrical Connection to Glucose Oxidase Using Aligned Single Walled Carbon Nanotube Arrays
Abstract
Direct electron transfer between an electrode and the redox active centre of glucose oxidase, flavin adenine dinucleotide (FAD), is probed using carbon nanotube modified gold electrodes. Gold electrodes are first modified with a self‐assembled monolayer of cysteamine and then shortened single walled carbon nanotubes (SWNT) are aligned normal to the electrode surface by self‐assembly. The electrochemistry of these aligned nanotube electrode arrays is initially investigated using potassium ferricyanide which showed SWNT act as nanoelectrodes with the ends of the tubes more electrochemically active than the walls. Subsequently the nanotubes are plugged into the enzymes in one of two ways. In the first method, native glucose oxidase is covalently attached to the ends of the aligned tubes which allowed close approach to FAD and direct electron transfer to be observed with a rate constant of 0.3 s−1. In the second strategy, FAD was attached to the ends of the tubes and the enzyme reconstituted around the surface immobilized FAD. This latter approach allowed more efficient electron transfer to the FAD with a rate constant of 9 s−1.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Laviron, E. (1979) · Journal of Electroanalytical Chemistry and Interfacial Electrochemistry · doi:10.1016/s0022-0728(79)80075-3 · Cited by 7,234
Liu, J., Rinzler, A. G., Dai, H., Hafner, J. H., Bradley, R. K., Boul, P. J., Lu, A., Iverson, T., Shelimov, K., Huffman, C. B., et al. (1998) · Science · doi:10.1126/science.280.5367.1253 · Cited by 2,903
Self-citationSolubilization of Carbon Nanotubes by Nafion toward the Preparation of Amperometric Biosensors
Wang, J., Musameh, M., & Lin, Y. (2003) · Journal of the American Chemical Society · doi:10.1021/ja028951v · Cited by 1,382
Glucose oxidase: an ideal enzyme
Wilson, R., & Turner, A. P. F. (1992) · Biosensors and Bioelectronics · doi:10.1016/0956-5663(92)87013-f · Cited by 1,350
"Plugging into Enzymes": Nanowiring of Redox Enzymes by a Gold Nanoparticle
Xiao, Y., Patolsky, F., Katz, E., Hainfeld, J. F., & Willner, I. (2003) · Science · doi:10.1126/science.1080664 · Cited by 1,270
Protein Electrochemistry Using Aligned Carbon Nanotube Arrays
Gooding, J. J., Wibowo, R., Liu, Yang, W., Losic, D., Orbons, S., Mearns, F. J., Shapter, J. G., & Hibbert, D. B. (2003) · Journal of the American Chemical Society · doi:10.1021/ja035722f · Cited by 881
Self-citationElectrical wiring of redox enzymes
Heller, A. (1990) · Accounts of Chemical Research · doi:10.1021/ar00173a002 · Cited by 788
Direct electron transfer of glucose oxidase on carbon nanotubes
Guiseppi-Elie, A., Lei, C., & Baughman, R. H. (2002) · Nanotechnology · doi:10.1088/0957-4484/13/5/303 · Cited by 629
Electrochemical Sensors Based on Carbon Nanotubes
Zhao, Q., Gan, Z., & Zhuang, Q. (2002) · Electroanalysis · doi:10.1002/elan.200290000 · Cited by 622
Long‐Range Electrical Contacting of Redox Enzymes by SWCNT Connectors
Patolsky, F., Weizmann, Y., & Willner, I. (2004) · Angewandte Chemie International Edition · doi:10.1002/anie.200353275 · Cited by 609
Cited by
Electrochemical Glucose Biosensors
Wang, J. (2008) · Chemical Reviews · doi:10.1021/cr068123a · Cited by 3,498
Carbon Nanomaterials in Biosensors: Should You Use Nanotubes or Graphene?
Yang, W., Ratinac, K. R., Ringer, S. P., Thordarson, P., Gooding, J. J., & Braet, F. (2010) · Angewandte Chemie International Edition · doi:10.1002/anie.200903463 · Cited by 1,431
Self-citationElectrochemical non-enzymatic glucose sensors
Park, S., Boo, H., & Chung, T. D. (2006) · Analytica Chimica Acta · doi:10.1016/j.aca.2005.05.080 · Cited by 1,159
Gooding, J. J. (2005) · Electrochimica Acta · doi:10.1016/j.electacta.2004.08.052 · Cited by 1,060
Self-citationBiosensors based on carbon nanotubes
Balasubramanian, K., & Burghard, M. (2006) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-006-0314-8 · Cited by 727
New materials for electrochemical sensing VI: Carbon nanotubes
Merkoçi, A., Pumera, M., Llopis, X., Pérez, B., del Valle, M., & Alegret, S. (2005) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2005.03.019 · Cited by 685
Wongkaew, N., Simsek, M., Griesche, C., & Baeumner, A. J. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00172 · Cited by 657
Carbon nanotubes for electrochemical biosensing
RIVAS, G., RUBIANES, M., RODRIGUEZ, M., FERREYRA, N., LUQUE, G., PEDANO, M., MISCORIA, S., & PARRADO, C. (2007) · Talanta · doi:10.1016/j.talanta.2007.10.013 · Cited by 554
New Nanostructured TiO2 for Direct Electrochemistry and Glucose Sensor Applications
Bao, S., Li, C. M., Zang, J., Cui, X., Qiao, Y., & Guo, J. (2008) · Advanced Functional Materials · doi:10.1002/adfm.200700728 · Cited by 446
Electrochemical Sensors Based on Carbon Nanotubes
Ahammad, A. J. S., Lee, J.-J., & Rahman, M. A. (2009) · Sensors · doi:10.3390/s90402289 · Cited by 371
Nanomaterials for bio-functionalized electrodes: recent trends
Walcarius, A., Minteer, S. D., Wang, J., Lin, Y., & Merkoçi, A. (2013) · Journal of Materials Chemistry B · doi:10.1039/c3tb20881h · Cited by 366
Electrochemistry at carbon nanotubes: perspective and issues
Dumitrescu, I., Unwin, P. R., & Macpherson, J. V. (2009) · Chemical Communications · doi:10.1039/b909734a · Cited by 325
Status of biomolecular recognition using electrochemical techniques
Sadik, O. A., Aluoch, A. O., & Zhou, A. (2009) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2008.10.003 · Cited by 315
Electrochemistry and Electroanalytical Applications of Carbon Nanotubes: A Review
Gong, K., Yan, Y., Zhang, M., Su, L., Xiong, S., & Mao, L. (2005) · Analytical Sciences · doi:10.2116/analsci.21.1383 · Cited by 297
Glucose oxidase anode for biofuel cell based on direct electron transfer
Ivnitski, D., Branch, B., Atanassov, P., & Apblett, C. (2006) · Electrochemistry Communications · doi:10.1016/j.elecom.2006.05.024 · Cited by 291
Carbon Nanotube (CNT)-Based Biosensors
Ferrier, D. C., & Honeychurch, K. C. (2021) · Biosensors · doi:10.3390/bios11120486 · Cited by 287
Recent developments in nanostructure based electrochemical glucose sensors
Zaidi, S. A., & Shin, J. H. (2016) · Talanta · doi:10.1016/j.talanta.2015.11.033 · Cited by 281
Recent advances in carbon nanotube based electrochemical biosensors
Gupta, S., Murthy, C. N., & Prabha, C. R. (2018) · International Journal of Biological Macromolecules · doi:10.1016/j.ijbiomac.2017.12.038 · Cited by 279
Carbon Nanotubes in Analytical Sciences
Merkoçi, A. (2006) · Microchimica Acta · doi:10.1007/s00604-005-0439-z · Cited by 270
Metadata
- Authors
- Liu, J., Chou, A., Rahmat, W., Paddon‐Row, M. N., & Gooding, J. J.
- Venue
- Electroanalysis
- Publisher
- Wiley
- Published
- 2005-01
- Volume
- 17
- Issue
- 1
- Pages
- 38-46
- ISSN
- 1040-0397 (ISSN-L)
- 1521-4109
- OpenAlex
- W2088365189
- Cited by
- 307
- References
- 28
- FWCI
- 16.02
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.