The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Impedance Spectroscopy: A Powerful Tool for Rapid Biomolecular Screening and Cell Culture Monitoring
Abstract
Dielectric spectroscopy or Electrochemical impedance spectroscopy (EIS) is traditionally used in corrosion monitoring, coatings evaluation, batteries, and electrodeposition and semiconductor characterization. However, in recent years, it is gaining widespread application in biotechnology, tissue engineering, and characterization of biological cells, disease diagnosis and cell culture monitoring. This article discusses the principles and implementation of dielectric spectroscopy in these bioanalytical applications. It provides examples of EIS as label‐free, mediator‐free strategies for rapid screening of biocompatible surfaces, monitoring pathogenic bacteria, as well as the analysis of heterogeneous systems, especially biological cells and tissues. Descriptions are given of the application of nanoparticles to improve the analytical sensitivities in EIS. Specific examples are given of the detection of base pair mismatches in the DNA sequence of Hepatitis B disease, TaySach's disease and Microcystis spp. Others include the EIS detection of viable pathogenic bacteria and the influence of nanomaterials in enhancing biosensor performance. Expanding applications in tissue engineering such as adsorption of proteins onto thiolated hexa(ethylene glycol)‐terminated (EG6) self‐assembled monolayer (SAM) are discussed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Survey of Structure−Property Relationships of Surfaces that Resist the Adsorption of Protein
Ostuni, E., Chapman, R. G., Holmlin, R. E., Takayama, S., & Whitesides, G. M. (2001) · Langmuir · doi:10.1021/la010384m · Cited by 1,799
Cited by
Label‐Free Impedance Biosensors: Opportunities and Challenges
Daniels, J. S., & Pourmand, N. (2007) · Electroanalysis · doi:10.1002/elan.200603855 · Cited by 1,192
New Horizons for Diagnostics and Therapeutic Applications of Graphene and Graphene Oxide
Feng, L., Wu, L., & Qu, X. (2013) · Advanced Materials · doi:10.1002/adma.201203229 · Cited by 632
Feng, L., Chen, Y., Ren, J., & Qu, X. (2011) · Biomaterials · doi:10.1016/j.biomaterials.2011.01.002 · Cited by 476
Impedimetric immunosensors—A review
Prodromidis, M. I. (2010) · Electrochimica Acta · doi:10.1016/j.electacta.2009.01.081 · Cited by 347
Impedance spectroscopy: Over 35 years of electrochemical sensor optimization
Pejcic, B., & De Marco, R. (2006) · Electrochimica Acta · doi:10.1016/j.electacta.2006.04.025 · Cited by 270
Metadata
- Authors
- K'Owino, I. O., & Sadik, O. A.
- Venue
- Electroanalysis
- Publisher
- Wiley
- Published
- 2005-12
- Volume
- 17
- Issue
- 23
- Pages
- 2101-2113
- ISSN
- 1040-0397 (ISSN-L)
- 1521-4109
- OpenAlex
- W2052131898
- Cited by
- 292
- References
- 1
- FWCI
- 4.38
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Impedance Spectroscopy: A Powerful Tool for Rapid Biomolecular Screening and Cell Culture Monitoring. https://app.cochat.ai/papers/10.1002/elan.200503371
- The paper
- K'Owino, I. O., & Sadik, O. A. (2005). Impedance Spectroscopy: A Powerful Tool for Rapid Biomolecular Screening and Cell Culture Monitoring. Electroanalysis. https://doi.org/10.1002/elan.200503371
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.