The DOI matches its Crossref record; 61 of the 61 references it cites were found in a registry or an index.
Impedance Spectroscopy: A Powerful Tool for Rapid Biomolecular Screening and Cell Culture Monitoring
Abstract
Dielectric spectroscopy or Electrochemical impedance spectroscopy (EIS) is traditionally used in corrosion monitoring, coatings evaluation, batteries, and electrodeposition and semiconductor characterization. However, in recent years, it is gaining widespread application in biotechnology, tissue engineering, and characterization of biological cells, disease diagnosis and cell culture monitoring. This article discusses the principles and implementation of dielectric spectroscopy in these bioanalytical applications. It provides examples of EIS as label‐free, mediator‐free strategies for rapid screening of biocompatible surfaces, monitoring pathogenic bacteria, as well as the analysis of heterogeneous systems, especially biological cells and tissues. Descriptions are given of the application of nanoparticles to improve the analytical sensitivities in EIS. Specific examples are given of the detection of base pair mismatches in the DNA sequence of Hepatitis B disease, TaySach's disease and Microcystis spp. Others include the EIS detection of viable pathogenic bacteria and the influence of nanomaterials in enhancing biosensor performance. Expanding applications in tissue engineering such as adsorption of proteins onto thiolated hexa(ethylene glycol)‐terminated (EG6) self‐assembled monolayer (SAM) are discussed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Applications of magnetic nanoparticles in biomedicine
Pankhurst, Q. A., Connolly, J., Jones, S. K., & Dobson, J. (2003) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/36/13/201 · Cited by 5,881
Applications of Magnetic Nanoparticles in Biomedicine
Bárcena, C., Sra, A. K., & Gao, J. (2009) · Nanoscale Magnetic Materials and Applications · doi:10.1007/978-0-387-85600-1_20 · Cited by 2,565
Self-Assembled Organic Monolayers: Model Systems for Studying Adsorption of Proteins at Aurfaces
Prime, K. L., & Whitesides, G. M. (1991) · Science · doi:10.1126/science.252.5009.1164 · Cited by 1,831
A Survey of Structure−Property Relationships of Surfaces that Resist the Adsorption of Protein
Ostuni, E., Chapman, R. G., Holmlin, R. E., Takayama, S., & Whitesides, G. M. (2001) · Langmuir · doi:10.1021/la010384m · Cited by 1,799
Prime, K. L., & Whitesides, G. M. (1993) · Journal of the American Chemical Society · doi:10.1021/ja00076a032 · Cited by 1,620
Katz, E., & Willner, I. (2003) · Electroanalysis · doi:10.1002/elan.200390114 · Cited by 1,351
Harder, P., Grunze, M., Dahint, R., Whitesides, G. M., & Laibinis, P. E. (1998) · The Journal of Physical Chemistry B · doi:10.1021/jp972635z · Cited by 1,290
Zwitterionic SAMs that Resist Nonspecific Adsorption of Protein from Aqueous Buffer
Holmlin, R. E., Chen, X., Chapman, R. G., Takayama, S., & Whitesides, G. M. (2001) · Langmuir · doi:10.1021/la0015258 · Cited by 891
Zhu, H., & Snyder, M. (2003) · Current Opinion in Chemical Biology · doi:10.1016/s1367-5931(02)00005-4 · Cited by 870
The interaction of proteins with solid surfaces
Gray, J. J. (2004) · Current Opinion in Structural Biology · doi:10.1016/j.sbi.2003.12.001 · Cited by 797
Wegener, J., Keese, C. R., & Giaever, I. (2000) · Experimental Cell Research · doi:10.1006/excr.2000.4919 · Cited by 769
Faucheux, N., Schweiss, R., Lützow, K., Werner, C., & Groth, T. (2004) · Biomaterials · doi:10.1016/j.biomaterials.2003.09.069 · Cited by 729
Jianrong, C., Yuqing, M., Nongyue, H., Xiaohua, W., & Sijiao, L. (2004) · Biotechnology Advances · doi:10.1016/j.biotechadv.2004.03.004 · Cited by 573
Single-base mismatch detection based on charge transduction through DNA
Kelley, S. (1999) · Nucleic Acids Research · doi:10.1093/nar/27.24.4830 · Cited by 495
Ostuni, E., Yan, L., & Whitesides, G. M. (1999) · Colloids and Surfaces B: Biointerfaces · doi:10.1016/s0927-7765(99)00004-1 · Cited by 453
Surfaces that resist bioadhesion
Kingshott, P., & Griesser, H. J. (1999) · Current Opinion in Solid State and Materials Science · doi:10.1016/s1359-0286(99)00018-2 · Cited by 374
A high density microelectrode array biosensor for detection of E. coli O157:H7
Radke, S. M., & Alocilja, E. C. (2005) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2004.07.021 · Cited by 371
Detection of single-base DNA mutations by enzyme-amplified electronic transduction
Patolsky, F., Lichtenstein, A., & Willner, I. (2001) · Nature Biotechnology · doi:10.1038/85704 · Cited by 368
Yang, L., Li, Y., Griffis, C. L., & Johnson, M. G. (2004) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2003.10.009 · Cited by 302
Acetylcholinesterase inhibitors: novel activities of old molecules
RACCHI, M. (2004) · Pharmacological Research · doi:10.1016/j.phrs.2003.12.027 · Cited by 288
Materials and techniques for electrochemical biosensor design and construction
Zhang, S. (2000) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(00)00076-2 · Cited by 286
Hoogvliet, J. C., Dijksma, M., Kamp, B., & van Bennekom, W. P. (2000) · Analytical Chemistry · doi:10.1021/ac991215y · Cited by 283
Enzyme or protein immobilization techniques for applications in biosensor design
Scouten, W. H., Luong, J. H. T., & Brown, R. S. (1995) · Trends in biotechnology · doi:10.1016/s0167-7799(00)88935-0 · Cited by 269
Recent Developments, Characteristics, and Potential Applications of Electrochemical Biosensors
Mehrvar, M., & Abdi, M. (2004) · Analytical Sciences · doi:10.2116/analsci.20.1113 · Cited by 266
Electronic Detection of Single-Base Mismatches in DNA with Ferrocene-Modified Probes
Yu, C. J., Wan, Y., Yowanto, H., Li, J., Tao, C., James, M. D., Tan, C. L., Blackburn, G. F., & Meade, T. J. (2001) · Journal of the American Chemical Society · doi:10.1021/ja010045f · Cited by 260
Impedance microbiology—a rapid change for microbiologists
Silley, P., & Forsythe, S. (1996) · Journal of Applied Bacteriology · doi:10.1111/j.1365-2672.1996.tb03215.x · Cited by 203
Fernández-Sánchez, C., McNeil, C. J., & Rawson, K. (2005) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2004.08.010 · Cited by 196
Patolsky, F., Katz, E., Bardea, A., & Willner, I. (1999) · Langmuir · doi:10.1021/la981682v · Cited by 191
Pencil-based renewable biosensor for label-free electrochemical detection of DNA hybridization
Wang, J., & Kawde, A.-N. (2001) · Analytica Chimica Acta · doi:10.1016/s0003-2670(00)01318-0 · Cited by 191
Zhai, J., Cui, H., & Yang, R. (1997) · Biotechnology Advances · doi:10.1016/s0734-9750(97)00003-7 · Cited by 187
Mena, M. L., Yáñez-Sedeño, P., & Pingarrón, J. M. (2005) · Analytical Biochemistry · doi:10.1016/j.ab.2004.07.038 · Cited by 179
Rational Approaches to the Design of Cationic Gemini Surfactants for Gene Delivery
McGregor, C., Perrin, C., Monck, M., Camilleri, P., & Kirby, A. J. (2001) · Journal of the American Chemical Society · doi:10.1021/ja005681c · Cited by 177
Zhu, B., Eurell, T., Gunawan, R., & Leckband, D. (2001) · Journal of Biomedical Materials Research · doi:10.1002/1097-4636(20010905)56:3<406::aid-jbm1110>3.0.co;2-r · Cited by 165
Infection control and quality health care in the new millenium
Pittet, D. (2005) · American Journal of Infection Control · doi:10.1016/j.ajic.2004.11.004 · Cited by 153
Patolsky, F., Katz, E. Y., & Willner, I. (2002) · Angewandte Chemie International Edition · doi:10.1002/1521-3773(20020916)41:18<3398::aid-anie3398>3.0.co;2-w · Cited by 137
Felice, C. J., Madrid, R. E., Olivera, J. M., Rotger, V. I., & Valentinuzzi, M. E. (1999) · Journal of Microbiological Methods · doi:10.1016/s0167-7012(98)00098-0 · Cited by 128
Factors that influence the mutagenic patterns of DNA adducts from chemical carcinogens
Seo, K.-Y., Jelinsky, S. A., & Loechler, E. L. (2000) · Mutation Research/Reviews in Mutation Research · doi:10.1016/s1383-5742(00)00047-8 · Cited by 126
Glucose biosensor based on ENFET doped with SiO2 nanoparticles
Luo, X., Xu, J., Zhao, W., & Chen, H. (2003) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2003.08.024 · Cited by 124
Moulton, S. E., Barisci, J. N., Bath, A., Stella, R., & Wallace, G. G. (2004) · Electrochimica Acta · doi:10.1016/j.electacta.2004.03.034 · Cited by 105
Impedimetric immunosensor using avidin–biotin for antibody immobilization
Ouerghi, O., Touhami, A., Jaffrezic-Renault, N. J., Martelet, C., Ouada, H. B., & Cosnier, S. (2002) · Bioelectrochemistry · doi:10.1016/s1567-5394(02)00029-4 · Cited by 104
Electrochemical biosensors based on enzymes immobilized in electropolymerized films
Trojanowicz, M., & Krawczyk, T. K. V. (1995) · Microchimica Acta · doi:10.1007/bf01248249 · Cited by 100
Cellular Dielectric Spectroscopy: A Powerful New Approach to Label-Free Cellular Analysis
Ciambrone, G. J., Liu, V. F., Lin, D. C., et al. (2004) · SLAS DISCOVERY · doi:10.1177/1087057104267788 · Cited by 96
Sargent, A., & Sadik, O. A. (1999) · Electrochimica Acta · doi:10.1016/s0013-4686(99)00265-0 · Cited by 94
Self-citationCapadona, J. R., Collard, D. M., & García, A. J. (2002) · Langmuir · doi:10.1021/la026244+ · Cited by 89
Kharitonov, A. B., Wasserman, J., Katz, E. Y., & Willner, I. (2001) · The Journal of Physical Chemistry B · doi:10.1021/jp0045383 · Cited by 89
Patolsky, F., Lichtenstein, A., & Willner, I. (2003) · Chemistry - A European Journal · doi:10.1002/chem.200390131 · Cited by 83
Suehiro, J., Noutomi, D., Shutou, M., et al. (2003) · Journal of Electrostatics · doi:10.1016/s0304-3886(03)00062-7 · Cited by 71
A multicellular spheroid-based sensor for anti-cancer therapeutics
Thielecke, H., Mack, A., & Robitzki, A. A. (2001) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(01)00140-3 · Cited by 65
Cosman, N. P., Fatih, K., & Roscoe, S. G. (2004) · Journal of Electroanalytical Chemistry · doi:10.1016/j.jelechem.2004.08.007 · Cited by 63
Saum, A. G. E., Cumming, R. H., & Rowell, F. J. (1998) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(97)00129-2 · Cited by 62
Biological responses to cationically charged phosphorylcholine-based materials in vitro
Rose, S. F., Lewis, A. L., Hanlon, G. W., & Lloyd, A. W. (2004) · Biomaterials · doi:10.1016/j.biomaterials.2003.12.016 · Cited by 56
Medium and interface components in impedance microbiology
Felice, C. J., & Valentinuzzi, M. E. (1999) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.804577 · Cited by 56
Functionalization of Si/SiO2 substrates with homooligonucleotides for a DNA biosensor
Cloarec, J., Martin, J. R., Polychronakos, C., Lawrence, I., Lawrence, M. F., & Souteyrand, É. (1999) · Sensors and Actuators B Chemical · doi:10.1016/s0925-4005(99)00102-1 · Cited by 51
Enzyme-Modulated Cleavage of dsDNA for Studying Interfacial Biomolecular Interactions
Yan, F., & Sadik, O. A. (2001) · Journal of the American Chemical Society · doi:10.1021/ja005719l · Cited by 48
Self-citationZhang, Y., Fung, Y., Sun, H. K., Zhu, D., & Yao, S. (2005) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2004.12.123 · Cited by 40
Yu, Y. H., & Jin, G. (2004) · Journal of Colloid and Interface Science · doi:10.1016/j.jcis.2004.09.021 · Cited by 35
Wright, J. E. I., Cosman, N. P., Fatih, K., Omanovic, S., & Roscoe, S. G. (2003) · Journal of Electroanalytical Chemistry · doi:10.1016/j.jelechem.2003.10.031 · Cited by 34
K'Owino, I. O., Agarwal, R., & Sadik, O. A. (2003) · Langmuir · doi:10.1021/la0265272 · Cited by 28
Self-citationAbdelMalek, F., Shadaram, M., & Boushriha, H. (2001) · Sensors and Actuators B Chemical · doi:10.1016/s0925-4005(00)00657-2 · Cited by 18
Chang, C.-H., Liao, J., Chen, J. J., Ju, M., & Lin, C. K. (2004) · Langmuir · doi:10.1021/la040097t · Cited by 13
Zhou, A., Zhang, J., Xie, Q., & Yao, S. (2001) · Biomaterials · doi:10.1016/s0142-9612(00)00442-7 · Cited by 10
Cited by
Label‐Free Impedance Biosensors: Opportunities and Challenges
Daniels, J. S., & Pourmand, N. (2007) · Electroanalysis · doi:10.1002/elan.200603855 · Cited by 1,192
The use of electrochemical impedance spectroscopy for biosensing
Lisdat, F., & Schäfer, D. (2008) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-008-1970-7 · Cited by 858
New Horizons for Diagnostics and Therapeutic Applications of Graphene and Graphene Oxide
Feng, L., Wu, L., & Qu, X. (2013) · Advanced Materials · doi:10.1002/adma.201203229 · Cited by 632
Feng, L., Chen, Y., Ren, J., & Qu, X. (2011) · Biomaterials · doi:10.1016/j.biomaterials.2011.01.002 · Cited by 476
Single cell dielectric spectroscopy
Morgan, H., Sun, T., Holmes, D., Gawad, S., & Green, N. G. (2007) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/40/1/s10 · Cited by 445
Metadata
- Authors
- K'Owino, I. O., & Sadik, O. A.
- Venue
- Electroanalysis
- Publisher
- Wiley
- Published
- 2005-12
- Volume
- 17
- Issue
- 23
- Pages
- 2101-2113
- ISSN
- 1040-0397 (ISSN-L)
- 1521-4109
- OpenAlex
- W2052131898
- Cited by
- 292
- References
- 61
- FWCI
- 4.38
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.