Bicomponent Microneedle Array Biosensor for Minimally‐Invasive Glutamate Monitoring
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
This article describes the design of a new and attractive minimally‐invasive bicomponent microneedle sensing device for the electrochemical monitoring of the excitatory neurotransmitter glutamate and glucose. The new device architecture relies on the close integration of solid and hollow microneedles into a single biosensor array device containing multiple microcavities. Such microcavities facilitate the electropolymeric entrapment of the recognition enzyme within each microrecess. The resulting microneedle biosensor array can be employed as a minimally‐invasive on‐body transdermal patch, obviating the extraction/sampling of the biological fluid, thereby simplifying device requirements. The new concept is demonstrated for the electropolymeric entrapment of glutamate oxidase and glucose oxidase within a poly(o‐phenylenediamine) (PPD) thin film. The PPD‐based enzyme entrapment methodology enables the effective rejection of coexisting electroactive interferents without compromising the sensitivity or response time of the device. The resulting microneedle‐based glutamate and glucose biosensors thus exhibit high selectivity, sensitivity, speed, and stability in both buffer and undiluted human serum. High‐fidelity glutamate measurements down to the 10 µM level are obtained in serum. The attractive recess design also serves to protect the enzyme layer upon insertion into the skin. This simple, yet robust microneedle design is well‐suited for diverse biosensing applications in which real‐time metabolite monitoring is a core requirement.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Electrochemical Glucose Biosensors
Wang, J. (2008) · Chemical Reviews · doi:10.1021/cr068123a · Cited by 3,498
Self-citationKratz (2004) · doi:10.1056/nejmcpc049016 · Cited by 593
Cited by
Broza, Y. Y., Zhou, X., Yuan, M., Qu, D., Zheng, Y., Vishinkin, R., Khatib, M., Wu, W., & Haick, H. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.9b00437 · Cited by 461
Wearable Electrochemical Glucose Sensors in Diabetes Management: A Comprehensive Review
Saha, T., Del Caño, R., Mahato, K., De la Paz, E., Chen, C., Ding, S., Yin, L., & Wang, J. (2023) · Chemical Reviews · doi:10.1021/acs.chemrev.3c00078 · Cited by 442
Self-citationA review study of (bio)sensor systems based on conducting polymers
Ates, M. (2013) · Materials Science and Engineering: C · doi:10.1016/j.msec.2013.01.035 · Cited by 431
Conducting polymer-based electrochemical biosensors for neurotransmitters: A review
Moon, J.-M., Thapliyal, N., Hussain, K. K., Goyal, R. N., & Shim, Y.-B. (2018) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2017.11.069 · Cited by 390
Non-invasive mouthguard biosensor for continuous salivary monitoring of metabolites
Kim, J., Valdés-Ramírez, G., Bandodkar, A. J., Jia, W., Martinez, A. G., Ramírez, J., Mercier, P., & Wang, J. (2014) · The Analyst · doi:10.1039/c3an02359a · Cited by 367
Self-citation
Metadata
- Authors
- Windmiller, J. R., Valdés‐Ramírez, G., Zhou, N., Zhou, M., Miller, P. R., Jin, C., Brozik, S. M., Polsky, R., Katz, E., Narayan, R., & Wang, J.
- Venue
- Electroanalysis
- Publisher
- Wiley
- Published
- 2011-09-06
- Volume
- 23
- Issue
- 10
- Pages
- 2302-2309
- ISSN
- 1040-0397 (ISSN-L)
- 1521-4109
- OpenAlex
- W2098338590
- Cited by
- 129
- References
- 2
- FWCI
- 4.23
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.