Biofuel Cell Operating in Vivo in Rat
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Biocatalytic electrodes made of buckypaper were modified with PQQ‐dependent glucose dehydrogenase on the anode and with laccase on the cathode. The enzyme modified electrodes were assembled in a biofuel cell which was first characterized in human serum solution and then the electrodes were placed onto exposed rat cremaster tissue. Glucose and oxygen dissolved in blood were used as the fuel and oxidizer, respectively, for the implanted biofuel cell operation. The steady‐state open circuitry voltage of 140±30 mV and short circuitry current of 10±3 µA (current density ca. 5 µA cm−2 based on the geometrical electrode area of 2 cm 2) were achieved in the in vivo operating biofuel cell. Future applications of implanted biofuel cells for powering of biomedical and sensor devices are discussed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Energy extraction from the biologic battery in the inner ear
Mercier, P. P., Lysaght, A. C., Bandyopadhyay, S., Chandrakasan, A. P., & Stankovic, K. M. (2012) · Nature Biotechnology · doi:10.1038/nbt.2394 · Cited by 217
Cited by
Tackling the Challenges of Enzymatic (Bio)Fuel Cells
Xiao, X., Xia, H.-Q., Wu, R., Bai, L., Yan, L., Magner, E., Cosnier, S., Lojou, E., Zhu, Z., & Liu, A. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.9b00115 · Cited by 504
Wireless and battery-free technologies for neuroengineering
Won, S. M., Cai, L., Gutruf, P., & Rogers, J. A. (2021) · Nature Biomedical Engineering · doi:10.1038/s41551-021-00683-3 · Cited by 360
Self-powered cardiovascular electronic devices and systems
Zheng, Q., Tang, Q., Wang, Z. L., & Li, Z. (2021) · Nature Reviews Cardiology · doi:10.1038/s41569-020-0426-4 · Cited by 348
Energy Harvesting from the Animal/Human Body for Self-Powered Electronics
Dagdeviren, C., Li, Z., & Wang, Z. L. (2017) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-071516-044517 · Cited by 348
Emerging Implantable Energy Harvesters and Self-Powered Implantable Medical Electronics
Jiang, D., Shi, B., Ouyang, H., Fan, Y., Wang, Z. L., & Li, Z. (2020) · ACS Nano · doi:10.1021/acsnano.9b08268 · Cited by 343
Metadata
- Authors
- Castorena‐Gonzalez, J. A., Foote, C., MacVittie, K., Halámek, J., Halámková, L., Martinez‐Lemus, L. A., & Katz, E.
- Venue
- Electroanalysis
- Publisher
- Wiley
- Published
- 2013-05-15
- Volume
- 25
- Issue
- 7
- Pages
- 1579-1584
- ISSN
- 1040-0397 (ISSN-L)
- 1521-4109
- OpenAlex
- W2012424426
- Cited by
- 139
- References
- 1
- FWCI
- 9.19
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.