The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Quantitation of microgram amounts of protein in two‐dimensional polyacrylamide gel electrophoresis sample buffer
Abstract
The concentration of protein actually solubilized in sample buffer in preparation for analysis by two‐dimensional polyacrylamide gel electrophoresis cannot be directly determined by the Lowry, Biuret, or Bradford protein methods due to interference by the combinational effect of presence of urea, detergents, carrier ampholytes, and thiol compounds in sample solubilization buffers. Determinations of the actual amount of protein solubilized and applied to gels is required to accurately quantitatively and qualitatively evaluate second‐dimension polypeptide maps. It was found that when sample buffer consisting of 9 M urea, 4 % Nonidet P‐40, 2 % Ampholines, and 2 % 2‐mercaptoethanol containing solubilized sample(s) was acidified prior to dilution, protein concentrations over a range of 0.5 to 50 μg could be reproducibly determined utilizing a modified Bradford assay. The modified assay generates two near‐linear segments, one over the range < 0.5 to 5 μg total protein that permits the application of Beer's law and a second linear response encompassing 5 to 50 μg total protein. The assay did not tolerate presence of greater than 0.1 % sodium dodecyl sulfate but addition of sodium chloride and protamine sulfate did not adversely affect protein quantitation. The modified assay allows direct quantitation of protein solubilized in sample buffers containing urea, carrier ampholytes, nonionic detergents, and thiol compounds.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
PROTEIN MEASUREMENT WITH THE FOLIN PHENOL REAGENT
Lowry, O., Rosebrough, N., Farr, A. L., & Randall, R. (1951) · Journal of Biological Chemistry · doi:10.1016/s0021-9258(19)52451-6 · Cited by 317,331
Bradford, M. M. (1976) · Analytical Biochemistry · doi:10.1016/0003-2697(76)90527-3 · Cited by 255,302
A rapid, sensitive, and versatile assay for protein using Coomassie brilliant blue G250
Sedmak, J. J., & Grossberg, S. E. (1977) · Analytical Biochemistry · doi:10.1016/0003-2697(77)90428-6 · Cited by 3,030
Refinement of the Coomassie blue method of protein quantitation
Spector, T. (1978) · Analytical Biochemistry · doi:10.1016/0003-2697(78)90327-5 · Cited by 1,583
Review of the folin phenol protein quantitation method of lowry, rosebrough, farr and randall
Peterson, G. L. (1979) · Analytical Biochemistry · doi:10.1016/0003-2697(79)90222-7 · Cited by 1,147
Reisner, A. H., Nemes, P., & Bucholtz, C. (1975) · Analytical Biochemistry · doi:10.1016/0003-2697(75)90461-3 · Cited by 615
PURIFICATION AND PROPERTIES OF FRUCTOSE-1,6-DIPHOSPHATASE
Mokrasch, L. C., & McGilvery, R. W. (1956) · Journal of Biological Chemistry · doi:10.1016/s0021-9258(18)65205-6 · Cited by 278
Pierce, J., & Suelter, C. H. (1977) · Analytical Biochemistry · doi:10.1016/0003-2697(77)90723-0 · Cited by 270
Assay for protein by dye binding
Kley, H. V., & Hale, S. M. (1977) · Analytical Biochemistry · doi:10.1016/0003-2697(77)90725-4 · Cited by 124
Application of Bradford's protein assay to adrenal gland subcellular fractions
Pollard, H. B., Menard, R. H., Brandt, H., Pazoles, C. J., Creutz, C. E., & Ramu, A. (1978) · Analytical Biochemistry · doi:10.1016/0003-2697(78)90805-9 · Cited by 107
Zaman, Z., & Verwilghen, R. L. (1979) · Analytical Biochemistry · doi:10.1016/0003-2697(79)90110-6 · Cited by 102
High resolution two‐dimensional polyacrylamide gel electrophoresis. II. Analysis and applications
Dunn, M. J., & Burghes, A. H. M. (1983) · Electrophoresis · doi:10.1002/elps.1150040302 · Cited by 54
Cited by
Improved silver staining of plant proteins, RNA and DNA in polyacrylamide gels
Blum, H., Beier, H., & Gross, H. J. (1987) · ELECTROPHORESIS · doi:10.1002/elps.1150080203 · Cited by 4,150
Aluminium Toxicity in Roots: An Investigation of Spatial Sensitivity and the Role of the Root Cap
RYAN, P. R., DITOMASO, J. M., & KOCHIAN, L. V. (1993) · Journal of Experimental Botany · doi:10.1093/jxb/44.2.437 · Cited by 593
Rabilloud, T., Adessi, C., Giraudel, A., & Lunardi, J. (1997) · ELECTROPHORESIS · doi:10.1002/elps.1150180303 · Cited by 459
Rabilloud, T., Valette, C., & Lawrence, J. J. (1994) · ELECTROPHORESIS · doi:10.1002/elps.11501501223 · Cited by 366
Link, A. J., Robison, K., & Church, G. M. (1997) · ELECTROPHORESIS · doi:10.1002/elps.1150180807 · Cited by 342
Metadata
- Authors
- Ramagli, L. S., & Rodriguez, L. V.
- Venue
- ELECTROPHORESIS
- Publisher
- Wiley
- Published
- 1985-01
- Volume
- 6
- Issue
- 11
- Pages
- 559-563
- ISSN
- 0173-0835 (ISSN-L)
- 1522-2683
- OpenAlex
- W2082416572
- Cited by
- 490
- References
- 12
- FWCI
- 2.63
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.