CoChat

A new multiphasic buffer system for sodium dodecyl sulfate‐polyacrylamide gel electrophoresis of proteins and peptides with molecular masses 100 000–1000, and their detection with picomolar sensitivity

Wiltfang, Jens, Arold, Norbert, Neuhoff, Volker · 1991 · ELECTROPHORESIS
Cited by 101

The DOI matches its Crossref record.

Abstract

A novel multiphasic buffer system for high resolution sodium dodecyl sulfate‐polyacrylamide gel electrophoresis of dansylated and nondansylated proteins/peptides in the relative molecular mass (Mr) range of 100 000–1000 is described. The system, based on Jovin's theory of multiphasic zone electrophoresis [1–3], allows complete stacking and destacking of proteins/ peptides within the above Mr, range. The buffer system uses Bicine and sulfate as trailing and leading ion, respectively, and Bistris and Tris as counter ions in the stacking and separating phase, respectively. Through selection of two different counterions – the characteristic feature of the present ionic system – the stacking limits of a multiphasic buffer system can be further widened, thus making it applicable to gel electrophoresis of a larger spectrum of rapidly migrating species, such as sodium dodecyl sulfate‐proteins/peptides and nucleic acids, than has been possible previously. Highly sensitive detection methods for proteins as well as for polypeptides down to approximately Mr, 1000 are described. Dansylated proteins/peptides were detected by their fluorescence either directly within the gel or following electroblotting into anion‐exchange of polyvinylidene difluoride membranes. The latter procedure resulted in detection sensitivities of approximately 1 ng. Nondansylated proteins/peptides were either detected within the gel by colloi dal Coomassie staining or by electroblotting into polyvinylidene difluoride membranes, followed by colloidal gold staining. Prior to both staining procedures the proteins/peptides were pretreated with glutardialdehyde in the presence of borate at near neutral pH values to generate protein/peptide polymers of poor solubility. For a given pH the efficiency of the latter procedure was significantly influenced by the nature of the bufferion used in the fixation buffer. In contrast to conventional fixation procedures even small polypeptides (Mr 1000) were immobilized and approximately 15 ng and 0.75 ng could be detected after colloidal Coomassie and colloidal gold staining, respectively.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/elps.1150120507

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Wiltfang, J., Arold, N., & Neuhoff, V.
Venue
ELECTROPHORESIS
Publisher
Wiley
Published
1991-01
Volume
12
Issue
5
Pages
352-366
ISSN
  • 0173-0835 (ISSN-L)
  • 1522-2683
OpenAlex
W2068566850
Cited by
101
References
0
FWCI
2.04
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.