The DOI matches its Crossref record.
A nonlinear wide‐range immobilized pH gradient for two‐dimensional electrophoresis and its definition in a relevant pH scale
Abstract
A new nonlinear immobilized pH gradient (IPG) is proposed as the first dimension for two‐dimensional electrophoresis. In comparison to conventional carrier ampholyte techniques, it offers better resolution and greater reproducibility whilst allowing application of higher protein loads. Furthermore, we have checked and supplemented existing data on p K values for the immobilized groups in the presence of 8M urea. This is necessary for pH gradients to be defined in a pH scale relevant to the focusing conditions such that spot positions can be related to amino acid compositions. The data will allow definition of pH scales for the temperature range 10–25°C and for a pH range covering the major part of the nonlinear pH gradient. With the latter, focusing positions are neither influenced by urea concentration nor by the choice or the concentration of detergent or carrier ampholyte. Temperature is the only parameter affecting focusing reproducibility and here any changes in focusing positions can be related to the amino acid compositions of peptides.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Betts, J. C., Lukey, P. T., Robb, L. C., McAdam, R. A., & Duncan, K. (2002) · Molecular Microbiology · doi:10.1046/j.1365-2958.2002.02779.x · Cited by 1,395
Progress with gene‐product mapping of the Mollicutes: Mycoplasma genitalium
Wasinger, V. C., Cordwell, S. J., Cerpa‐Poljak, A., Yan, J. X., Gooley, A. A., Wilkins, M. R., Duncan, M. W., Harris, R., Williams, K. L., & Humphery‐Smith, I. (1995) · ELECTROPHORESIS · doi:10.1002/elps.11501601185 · Cited by 962
Hydrolysis and amino acid composition analysis of proteins
Fountoulakis, M., & Lahm, H.-W. (1998) · Journal of Chromatography A · doi:10.1016/s0021-9673(98)00721-3 · Cited by 606
Proteome Map of the Chloroplast Lumen of Arabidopsis thaliana
Schubert, M., Petersson, U. A., Haas, B. J., Funk, C., Schröder, W. P., & Kieselbach, T. (2002) · Journal of Biological Chemistry · doi:10.1074/jbc.m108575200 · Cited by 438
Link, A. J., Robison, K., & Church, G. M. (1997) · ELECTROPHORESIS · doi:10.1002/elps.1150180807 · Cited by 342
Metadata
- Authors
- Bjellqvist, B., Pasquali, C., Ravier, F., Sanchez, J., & Hochstrasser, D.
- Venue
- ELECTROPHORESIS
- Publisher
- Wiley
- Published
- 1993-01
- Volume
- 14
- Issue
- 1
- Pages
- 1357-1365
- ISSN
- 0173-0835 (ISSN-L)
- 1522-2683
- OpenAlex
- W2058676872
- Cited by
- 381
- References
- 0
- FWCI
- 10.13
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A nonlinear wide‐range immobilized pH gradient for two‐dimensional electrophoresis and its definition in a relevant pH scale. https://app.cochat.ai/papers/10.1002/elps.11501401209
- The paper
- Bjellqvist, B., Pasquali, C., Ravier, F., Sanchez, J., & Hochstrasser, D. (1993). A nonlinear wide‐range immobilized pH gradient for two‐dimensional electrophoresis and its definition in a relevant pH scale. ELECTROPHORESIS. https://doi.org/10.1002/elps.11501401209
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.