The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Droplet fusion by alternating current (AC) field electrocoalescence in microchannels
Abstract
We present a system for the electrocoalescence of microfluidic droplets immersed in an immiscible solvent, where the undeformed droplet diameters are comparable to the channel diameter. The electrodes are not in direct contact with the carrier liquid or the droplets, thereby minimizing the risk of cross‐contamination between different coalescence events. Results are presented for the coalescence of buffered aqueous droplets in both quiescent and flowing fluorocarbon streams, and on‐flight coalescence is demonstrated. The capillary‐based system presented here is readily amenable to further miniaturization to any lab‐on‐a‐chip application where the conductivity of the droplets is much greater than the conductivity of the stream containing them, and should aid in the further application of droplet microreactors to biological analyses.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Millisecond Kinetics on a Microfluidic Chip Using Nanoliters of Reagents
Song, H., & Ismagilov, R. F. (2003) · Journal of the American Chemical Society · doi:10.1021/ja0354566 · Cited by 693
The interaction of falling water drops: coalescence
Brazier-Smith, P. R., Jennings, S. G., & Latham, J. (1972) · Proceedings of the Royal Society of London. A. Mathematical and Physical Sciences · doi:10.1098/rspa.1972.0016 · Cited by 340
Cited by
Seemann, R., Brinkmann, M., Pfohl, T., & Herminghaus, S. (2012) · Reports on Progress in Physics · doi:10.1088/0034-4885/75/1/016601 · Cited by 1,049
Surfactants in droplet-based microfluidics
Baret, J.-C. (2012) · Lab Chip · doi:10.1039/c1lc20582j · Cited by 649
High-throughput single-cell ChIP-seq identifies heterogeneity of chromatin states in breast cancer
Grosselin, K., Durand, A., Marsolier, J., Poitou, A., Marangoni, E., Nemati, F., Dahmani, A., Lameiras, S., Reyal, F., Frenoy, O., et al. (2019) · Nature Genetics · doi:10.1038/s41588-019-0424-9 · Cited by 466
Microfluidic high-throughput encapsulation and hydrodynamic self-sorting of single cells
Chabert, M., & Viovy, J.-L. (2008) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0708321105 · Cited by 344
Self-citationMazutis, L., Araghi, A. F., Miller, O. J., Baret, J.-C., Frenz, L., Janoshazi, A., Taly, V., Miller, B. J., Hutchison, J. B., Link, D., et al. (2009) · Analytical Chemistry · doi:10.1021/ac900403z · Cited by 263
Metadata
- Authors
- Chabert, M., Dorfman, K. D., & Viovy, J.
- Venue
- ELECTROPHORESIS
- Publisher
- Wiley
- Published
- 2005-09-30
- Volume
- 26
- Issue
- 19
- Pages
- 3706-3715
- ISSN
- 0173-0835 (ISSN-L)
- 1522-2683
- OpenAlex
- W2121057697
- Cited by
- 210
- References
- 2
- FWCI
- 3.61
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Droplet fusion by alternating current (AC) field electrocoalescence in microchannels. https://app.cochat.ai/papers/10.1002/elps.200500109
- The paper
- Chabert, M., Dorfman, K. D., & Viovy, J. (2005). Droplet fusion by alternating current (AC) field electrocoalescence in microchannels. ELECTROPHORESIS. https://doi.org/10.1002/elps.200500109
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.