The DOI matches its Crossref record.
β‐Actin is not a reliable loading control in Western blot analysis
Abstract
β‐Actin is often used as a loading control in Western blot analysis. We analyzed the ability of β‐actin‐specific antibodies to recognize differences in protein loading. We found that, at higher total protein loads as required for the detection of low‐abundance proteins, β‐actin‐specific antibodies failed to distinguish differences in actin protein levels. Diluting the antibody working solution or changing the incubation time had little effect on this phenomenon. This shows that β‐Actin is not a reliable loading control in Western blot analysis. In general, it appeared that, at longer incubation times, antibodies seem to be less able to pick up differences in the level of its target protein.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Reversible Ponceau staining as a loading control alternative to actin in Western blots
Romero-Calvo, I., Ocón, B., Martínez-Moya, P., Suárez, M. D., Zarzuelo, A., Martínez-Augustin, O., & de Medina, F. S. (2010) · Analytical Biochemistry · doi:10.1016/j.ab.2010.02.036 · Cited by 771
Aldridge, G. M., Podrebarac, D. M., Greenough, W. T., & Weiler, I. J. (2008) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2008.05.003 · Cited by 476
Coomassie staining as loading control in Western blot analysis
Welinder, C., & Ekblad, L. (2011) · Journal of Proteome Research · doi:10.1021/pr1011476 · Cited by 463
The Design of a Quantitative Western Blot Experiment
Taylor, S. C., & Posch, A. (2014) · BioMed Research International · doi:10.1155/2014/361590 · Cited by 408
Total protein analysis as a reliable loading control for quantitative fluorescent Western blotting
Eaton, S. L., Roche, S. L., Llavero Hurtado, M., Oldknow, K. J., Farquharson, C., Gillingwater, T. H., & Wishart, T. M. (2013) · PLoS ONE · doi:10.1371/journal.pone.0072457 · Cited by 403
Metadata
- Authors
- Dittmer, A., & Dittmer, J.
- Venue
- ELECTROPHORESIS
- Publisher
- Wiley
- Published
- 2006-07
- Volume
- 27
- Issue
- 14
- Pages
- 2844-2845
- ISSN
- 0173-0835 (ISSN-L)
- 1522-2683
- OpenAlex
- W2161968177
- Cited by
- 168
- References
- 0
- FWCI
- 0.98
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: β‐Actin is not a reliable loading control in Western blot analysis. https://app.cochat.ai/papers/10.1002/elps.200500785
- The paper
- Dittmer, A., & Dittmer, J. (2006). β‐Actin is not a reliable loading control in Western blot analysis. ELECTROPHORESIS. https://doi.org/10.1002/elps.200500785
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.