Selective enrichment and ultrasensitive identification of trace peptides in proteome analysis using transient capillary isotachophoresis/zone electrophoresis coupled with nano‐ESI‐MS
The DOI matches its Crossref record.
Abstract
Besides the complexity in protein samples of biological origin, probably the greatest challenge presently facing comprehensive proteome analysis is related to the large variation of protein relative abundances (>6 orders of magnitude), having potential biological significance in mammalian systems. As demonstrated in this work, transient capillary ITP/zone electrophoresis (CITP/CZE) provides selective analyte enrichment through electrokinetic stacking and extremely high resolving power toward protein and peptide mixtures. The result of the CITP process is that major components may be diluted, but trace compounds are concentrated. The on‐column transition of CITP to CZE minimizes additional band broadening while providing superior analyte resolution. Online coupling of transient CITP/CZE with nano‐ESI‐MS allows ultrasensitive detection of trace peptides at levels of subnanomolar concentration or subfemtomole mass in complex peptide mixtures. More importantly, selective enrichment of trace peptides enables the identification and sequence analysis of low‐abundance peptides co‐migrated with highly abundant species at a concentration ratio of 1:500 000. The combined CITP/CZE‐nano‐ESI‐MS system is demonstrated to be at least one to two orders of magnitude more sensitive than that attained in conventional electrophoretic and chromatographic‐based proteome technologies over a wide dynamic concentration range, potentially allowing comprehensive analysis of protein profiles within a small cell population and limited tissue samples using conventional mass spectrometers. Furthermore, the speed of CITP/CZE separation and the lack of column equilibration in CITP/CZE not only improve the throughput of proteome analysis, but also facilitate its seamless integration with other separation technologies in a multidimensional protein identification platform.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Breadmore, M. C., Shallan, A. I., Rabanes, H. R., Gstoettenmayr, D., Abdul Keyon, A. S., Gaspar, A., Dawod, M., & Quirino, J. P. (2013) · ELECTROPHORESIS · doi:10.1002/elps.201200396 · Cited by 372
On-line sample preconcentration in capillary electrophoresis
Simpson, S. L., Quirino, J. P., & Terabe, S. (2008) · Journal of Chromatography A · doi:10.1016/j.chroma.2007.11.001 · Cited by 342
Capillary electrophoresis of proteins 2005–2007
Dolník, V. (2008) · ELECTROPHORESIS · doi:10.1002/elps.200700584 · Cited by 164
Capillary electrophoresis applied to proteomic analysis
Fonslow, B. R., & Yates III, J. R. (2009) · Journal of Separation Science · doi:10.1002/jssc.200800592 · Cited by 92
Wang, C., Lee, C. S., Smith, R. D., & Tang, K. (2013) · Analytical Chemistry · doi:10.1021/ac401202c · Cited by 46
Self-citationWang, C., Lee, C. S., Smith, R. D., & Tang, K. (2012) · Analytical Chemistry · doi:10.1021/ac302616m · Cited by 38
Self-citation
Metadata
- Authors
- An, Y., Cooper, J. W., Balgley, B. M., & Lee, C. S.
- Venue
- ELECTROPHORESIS
- Publisher
- Wiley
- Published
- 2006-09
- Volume
- 27
- Issue
- 18
- Pages
- 3599-3608
- ISSN
- 0173-0835 (ISSN-L)
- 1522-2683
- OpenAlex
- W2058107531
- Cited by
- 50
- References
- 0
- FWCI
- 7.80
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.