Cited by 46Microfluidic and Capillary Electrophoresis ApplicationsMass Spectrometry Techniques and ApplicationsAdvanced Proteomics Techniques and Applications

Capillary Isotachophoresis-Nanoelectrospray Ionization-Selected Reaction Monitoring MS via a Novel Sheathless Interface for High Sensitivity Sample Quantification

Open access
Wang, Chenchen, Lee, Cheng S., Smith, Richard D., Tang, Keqi·2013·Analytical Chemistry

Abstract

A novel sheathless capillary isotachophoresis (CITP/CZE)-mass spectrometry (MS) interface featuring a large inner diameter (i.d.) separation capillary, and a detachable small i.d. porous electrospray ionization (ESI) emitter was developed in this study to simultaneously achieve large sample loading capacity and stable nanoESI operation. Crucial operating parameters, including sample loading volume, flow rate, and separation window, were systematically investigated to attain optimum CITP/CZE separation efficiency and MS detection sensitivity. The performance of CITP/CZE-nanoESI-MS using the new sheathless interface was evaluated for its achievable low limit of quantification (LOQ) by analyzing targeted peptides, leu-enkephalin and angiotensin II, spiked in a BSA tryptic digest matrix at different concentrations. A linear dynamic range spanning 4.5 orders of magnitude and a 10 pM LOQ with measurement reproducibility of the CV < 22% were obtained experimentally for both targeted peptides, representing a 5-fold sensitivity improvement as compared to using the sheath liquid interface developed previously.1.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/ac401202c

Cites

40 of 40 references verified0 citation errors · 0 not checkable

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

Flagged first, then by citations

1 of the 41 references couldn’t be matched to a known paper.

Research works printed but not linked: 4

  1. [16]Dong Y-M Chien K-Y Chen J-T Lin S-J Wang T-CV Yu J-S Journal of Separation Science 2013 n/a-n/a
  2. [22]Wilm MS Mann M International Journal of Mass Spectrometry and Ion Processes 1994 136 167 180
  3. [36]Ramautar R Busnel J-M Deelder AM Mayboroda OA Anal Chem 2012 84 885 892 22148170
  4. [41]Wang C Lee CS Smith RD Tang K Anal Chem 2012 84 10395 10403 23140208 PMC3547498

Cited by

Sorted by citations

Authors
Wang, C., Lee, C. S., Smith, R. D., & Tang, K.
Affiliations
  • University of Maryland, College Park (US)
  • Pacific Northwest National Laboratory (US)
Corresponding author
Tang, Keqi
Venue
Analytical Chemistry
Published
2013-07-08
Volume
85
Issue
15
Pages
7308-7315
ISSN
  • 0003-2700 (ISSN-L)
  • 1520-6882
OpenAlex
W1995204488
Cited by
46
References
41
Citations by year
2026: 2 · 2024: 1 · 2022: 1 · 2021: 1 · 2020: 5 · 2019: 2 · 2018: 4 · 2017: 7 · 2016: 8 · 2015: 5 · 2014: 9 · 2013: 1
FWCI
4.22
Type
journal article
Language
en
Open access
Locations
  • Analytical Chemistry (publishedVersion)
  • PubMed (publishedVersion)
  • PubMed Central (acceptedVersion)
Funders
  • National Institutes of Health (5p41gm103493-20)
  • National Cancer Institute (R21CA143177, R33CA155252)
  • National Institute of General Medical Sciences (8 P41 GM103493-10, R21GM103536, P41-GM103493)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Capillary Electrophoresis Applications
  • Physical Sciences › Chemistry › Spectroscopy › Mass Spectrometry Techniques and Applications
  • Physical Sciences › Chemistry › Spectroscopy › Advanced Proteomics Techniques and Applications
Keywords
capillary isotachophoresis, capillary zone electrophoresis, nanoelectrospray ionization, electrospray emitter, multiple reaction monitoring, peptide quantification, leu-enkephalin, angiotensin II, limit of quantification, sample loading capacity, tryptic digest
MeSH terms
Amino Acid Sequence, Animals, Cattle, Humans, Peptides, Spectrometry, Mass, Electrospray Ionization, Nanotechnology, Isotachophoresis

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review