The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Dielectrophoresis for the manipulation of nanobioparticles
Abstract
Dielectrophoresis (DEP) is a nondestructive electrokinetic mechanism with great potential for the manipulation of bioparticles. DEP is the movement of particles induced by polarization effects in nonuniform electric fields. Since the 1960s, this technique has been successfully used for the manipulation of microbioparticles, such as microorganisms. Moreover, due to the advances in microfabrication techniques, that allowed progressively smaller microstructures to be constructed, DEP can now be used for the manipulation of nanobioparticles. The first research studies on the DEP of nanobioparticles started in the 1990s. Since then, many research groups have carried out outstanding work with DEP of nanobioparticles such as macromolecules, virus, and spores. However, the need of a critical report that integrates these findings is evident. The aim of the present review is to depict the state‐of–the‐art on the use of DEP for the separation of nanobioparticles and the potential trends of novel applications of this technique. This review compiles and analyzes the significant findings obtained by many researchers. This publication is intended to provide the reader with state‐of‐the‐art information on many research studies focused on DEP to handle nanobioparticles.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Jones, T. B. (1995) · doi:10.1017/cbo9780511574498 · Cited by 2,786 · cited 1×
“Depending on the relative magnitude of e p and e m, the DEP force acting on a particle can cause it to move toward or away from the high field region, these two effects are called positive and negative DEP behavior, respectively [52, 53].”
Background
Cited by
Light at work: The use of optical forces for particle manipulation, sorting, and analysis
Jonáš, A., & Zemánek, P. (2008) · ELECTROPHORESIS · doi:10.1002/elps.200800484 · Cited by 356
Dielectrophoretic separation of bioparticles in microdevices: A review
Jubery, T. Z., Srivastava, S. K., & Dutta, P. (2014) · ELECTROPHORESIS · doi:10.1002/elps.201300424 · Cited by 262
Advancements in microfluidics for nanoparticle separation
Salafi, T., Zeming, K. K., & Zhang, Y. (2017) · Lab on a Chip · doi:10.1039/c6lc01045h · Cited by 261
Filter Performance of N99 and N95 Facepiece Respirators Against Viruses and Ultrafine Particles
Eninger, R. M., Honda, T., Adhikari, A., Heinonen-Tanski, H., Reponen, T., & Grinshpun, S. A. (2008) · The Annals of Occupational Hygiene · doi:10.1093/annhyg/men019 · Cited by 165
Metadata
- Authors
- Lapizco‐Encinas, B. H., & Rito‐Palomares, M.
- Venue
- ELECTROPHORESIS
- Publisher
- Wiley
- Published
- 2007-12
- Volume
- 28
- Issue
- 24
- Pages
- 4521-4538
- ISSN
- 0173-0835 (ISSN-L)
- 1522-2683
- OpenAlex
- W2040131629
- Cited by
- 205
- References
- 1
- FWCI
- 8.92
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Dielectrophoresis for the manipulation of nanobioparticles. https://app.cochat.ai/papers/10.1002/elps.200700303
- The paper
- Lapizco‐Encinas, B. H., & Rito‐Palomares, M. (2007). Dielectrophoresis for the manipulation of nanobioparticles. ELECTROPHORESIS. https://doi.org/10.1002/elps.200700303
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.