CoChat

Phosphoproteome analysis of human liver tissue by long‐gradient nanoflow LC coupled with multiple stage MS analysis

Han, Guanghui, Ye, Mingliang, Liu, Hongwei, Song, Chunxia, Sun, Deguang, Wu, Yifeng, Jiang, Xinning, Chen, Rui, Wang, Chunli, Wang, Liming, Zou, Hanfa · 2010 · ELECTROPHORESIS
Cited by 69

The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.

Abstract

Reversible protein phosphorylation plays a critical role in liver development and function. Comprehensively cataloging the phosphoproteins and their phosphorylation sites in human liver tissue will facilitate the understanding of physiological and pathological mechanisms of liver. Owing to lacking of efficient approach to fractionate phosphopeptides, nanoflow‐RPLC with long‐gradient elution was applied to reduce the complexity of the phosphopeptides in this study. Two approaches were performed to further improve the coverage of phosphoproteome analysis of human liver tissue. In one approach, ten‐replicated long‐gradient LC‐MS/MS runs were performed to analyze the enriched phosphopeptides, which resulted in the localization of 1080 phosphorylation sites from 495 proteins. In another approach, proteins from liver tissue were first fractionated by SDS‐PAGE and then long‐gradient LC‐MS/MS analysis was performed to analyze the phosphopeptides derived from each fraction, which resulted in the localization of 1786 phosphorylation sites from 911 proteins. The two approaches showed the complementation in phosphoproteome analysis of human liver tissue. Combining the results of the two approaches, identification of 2225 nonredundant phosphorylation sites from 1023 proteins was obtained. The confidence of phosphopeptide identifications was strictly controlled with false discovery rate (FDR)≤1% by a MS 2/MS 3 target‐decoy database search approach. Among the localized 2225 phosphorylated sites, as many as 70.07% (1559 phosphorylated sites) were also reported by others, which confirmed the high confidence of the sites determined in this study. Considering the data acquired from low accuracy mass spectrometer and processed by a conservative MS 2/MS 3 target‐decoy approach, the number of localized phosphorylation sites obtained for human liver tissue in this study is quite impressive.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/elps.200900493

Cites

7 of 7 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 7 references

Cited by

See all 69

Metadata

Authors
Han, G., Ye, M., Liu, H., Song, C., Sun, D., Wu, Y., Jiang, X., Chen, R., Wang, C., Wang, L., & Zou, H.
Venue
ELECTROPHORESIS
Publisher
Wiley
Published
2010-03
Volume
31
Issue
6
Pages
1080-1089
ISSN
  • 0173-0835 (ISSN-L)
  • 1522-2683
OpenAlex
W2140961919
Cited by
69
References
7
FWCI
4.70
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Phosphoproteome analysis of human liver tissue by long‐gradient nanoflow LC coupled with multiple stage MS analysis. https://app.cochat.ai/papers/10.1002/elps.200900493
The paper
Han, G., Ye, M., Liu, H., Song, C., Sun, D., Wu, Y., Jiang, X., Chen, R., Wang, C., Wang, L., & Zou, H. (2010). Phosphoproteome analysis of human liver tissue by long‐gradient nanoflow LC coupled with multiple stage MS analysis. ELECTROPHORESIS. https://doi.org/10.1002/elps.200900493

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.