Evaluation of a sheathless nanospray interface based on a porous tip sprayer for CE‐ESI‐MS coupling
Open accessThe DOI matches its Crossref record; 61 of the 61 references it cites were found in a registry or an index.
Abstract
The hyphenation of capillary electrophoresis (CE) with mass spectrometry (MS) is a powerful method to obtain high efficient, sensitive, and selective analyses. The successful coupling with electrospray ionization (ESI) source requires closed electric circuits for both the CE separation and the ESI processes. A wide range of interfaces has been proposed to satisfy this requirement. Among them, the new high sensitivity porous sprayer based on a porous tip achieves the electric connection by inserting the capillary outlet made of a porous material into an ESI needle filled with a conductive liquid and independently grounded. This device is compatible with the minute flow rates exhibited in CE and therefore makes possible the use of a nano‐electrospray behavior. In this work, this interface was evaluated for hyphenating a CE with a single quadrupole MS instrument for low molecular weight analytes. Investigations aimed at highlighting the most influent parameters thanks to a design of experiments, reaching the best performance in terms of sensitivity and stability. MS signal intensities of various pharmaceutical compounds (e.g. amphetamines, β‐blockers) emphasized high sensitivity and efficiency, while repeatability, expressed as relative standard deviation of corrected heights and areas, was suitable for quantitative purposes (<5%).
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
Analytical Properties of the Nanoelectrospray Ion Source
Wilm, M., & Mann, M. (1996) · Analytical Chemistry · doi:10.1021/ac9509519 · Cited by 1,868
Practical implications of some recent studies in electrospray ionization fundamentals
Cech, N. B., & Enke, C. G. (2001) · Mass Spectrometry Reviews · doi:10.1002/mas.10008 · Cited by 1,435
Electrospray ionization mass spectrometry : fundamentals, instrumentation, and applications
Cole, R. B. (1997) · Wiley eBooks · Cited by 1,140
Handbook of Chemometrics and Qualimetrics
Massart, D. L., Vandeginste, B. G. M., Buydens, L. M. C., Lewi, P. J., Smeyers-Verbeke, J., & Jong, S. D. (1998) · Cited by 1,085
Electrohydrodynamic spraying functioning modes: a critical review
Cloupeau, M., & Prunet-Foch, B. (1994) · Journal of Aerosol Science · doi:10.1016/0021-8502(94)90199-6 · Cited by 794
On-line mass spectrometric detection for capillary zone electrophoresis
Olivares, J. A., Nguyen, N. T., Yonker, C. R., & Smith, R. D. (1987) · Analytical Chemistry · doi:10.1021/ac00135a034 · Cited by 635
CLASSIFICATION OF THE MODES OF EHD SPRAYING
Jaworek, A., & Krupa, A. (1999) · Journal of Aerosol Science · doi:10.1016/s0021-8502(98)00787-3 · Cited by 569
Improved electrospray ionization interface for capillary zone electrophoresis-mass spectrometry
Smith, R. D., Barinaga, C. J., & Udseth, H. R. (1988) · Analytical Chemistry · doi:10.1021/ac00169a022 · Cited by 535
Schmidt, A., Karas, M., & Dülcks, T. (2003) · Journal of the American Society for Mass Spectrometry · doi:10.1016/s1044-0305(03)00128-4 · Cited by 534
Liquid chromatography/mass spectrometry
Covey, T. R., Lee, E. D., Bruins, A. P., & Henion, J. D. (1986) · Analytical Chemistry · doi:10.1021/ac00127a001 · Cited by 469
Research works printed but not linked: 4
- Haleem J. I., 2004, J. Chromatogr. A, 1053, 37
- Lewis, G. A., 1999, Pharm. Experimental Design
- Morgan, E., 1991, Chemometrics: Experimental Design
- Kerbarle, P., 1997, Electrospray Ionization Mass Spectrometry: Fundamentals, Instrumentation and Applications, 107
Cited by
Harstad, R. K., Johnson, A. C., Weisenberger, M. M., & Bowser, M. T. (2016) · Analytical Chemistry · doi:10.1021/acs.analchem.5b04125 · Cited by 158
Haselberg, R., de Jong, G. J., & Somsen, G. W. (2013) · Analytical Chemistry · doi:10.1021/ac303158f · Cited by 149
Stalmach, A., Albalat, A., Mullen, W., & Mischak, H. (2013) · ELECTROPHORESIS · doi:10.1002/elps.201200708 · Cited by 117
Bonvin, G., Schappler, J., & Rudaz, S. L. (2012) · Journal of Chromatography A · doi:10.1016/j.chroma.2012.07.019 · Cited by 127
Self-citationRecent trends of capillary electrophoresis‐mass spectrometry in proteomics research
Gomes, F. P., & Yates, J. R. (2019) · Mass Spectrometry Reviews · doi:10.1002/mas.21599 · Cited by 112
CE‐MS for the analysis of intact proteins 2010–2012
Haselberg, R., de Jong, G. J., & Somsen, G. W. (2013) · ELECTROPHORESIS · doi:10.1002/elps.201200439 · Cited by 96
Klepárník, K. (2012) · Electrophoresis · doi:10.1002/elps.201200488 · Cited by 83
Capillary Electrophoresis Mass Spectrometry as A Tool for Untargeted Metabolomics
García, A., Godzień, J., López‐Gonzálvez, Á., & Barbas, C. (2016) · Bioanalysis · doi:10.4155/bio-2016-0216 · Cited by 91
CE‐MS‐based proteomics in biomarker discovery and clinical application
Pontillo, C., Filip, S., Borràs, D. M., Mullen, W., Vlahou, A., & Mischak, H. (2015) · PROTEOMICS – Clinical Applications · doi:10.1002/prca.201400115 · Cited by 77
“Besides the aforementioned examples, additional applications of a sheathless interface in CE-MS have been reported in other publications [42, 44, 45].”
BackgroundOptimizing Mass Spectrometry Analyses: A Tailored Review on the Utility of Design of Experiments
Hecht, E. S., Oberg, A. L., & Muddiman, D. C. (2016) · Journal of the American Society for Mass Spectrometry · doi:10.1007/s13361-016-1344-x · Cited by 76
Zhong, X., Zhang, Z., Jiang, S., & Li, L. (2013) · Electrophoresis · doi:10.1002/elps.201300451 · Cited by 81
Gahoual, R., Biacchi, M., Chicher, J., Kühn, L., Hammann, P., Beck, A., Leize‐Wagner, E., & François, Y. (2014) · mAbs · doi:10.4161/mabs.36305 · Cited by 76
Batz, N. G., Mellors, J. S., Alarie, J. P., & Ramsey, J. M. (2014) · Analytical Chemistry · doi:10.1021/ac404106u · Cited by 65
Dual Nano-Electrospray for Probing Solution Interactions and Fast Reactions of Complex Biomolecules
Mark, L. P., Gill, M. C., Mahut, M., & Derrick, P. J. (2012) · European Journal of Mass Spectrometry · doi:10.1255/ejms.1198 · Cited by 62
Chetwynd, A. J., Guggenheim, E. J., Briffa, S. M., Thorn, J. A., Lynch, I., & Valsami‐Jones, E. (2018) · Nanomaterials · doi:10.3390/nano8020099 · Cited by 46
Moini, M., & Rollman, C. M. (2014) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.7106 · Cited by 38
Medina-Casanellas, S., Domínguez-Vega, E., Benavente, F., Sanz-Nebot, V., Somsen, G. W., & de Jong, G. J. (2014) · Journal of Chromatography A · doi:10.1016/j.chroma.2013.12.080 · Cited by 36
Gahoual, R., Beck, A., François, Y., & Leize‐Wagner, E. (2016) · Journal of Mass Spectrometry · doi:10.1002/jms.3735 · Cited by 38
“On the contrary, innovative CE-ESI-MS coupling strategies provide an optimal sensitivity especially because of operating flow rates (<50 nl/min), enabling the production of a nanoESI.([15,16])”
BackgroundBonvin, G., Schappler, J., & Rudaz, S. L. (2013) · Journal of Chromatography A · doi:10.1016/j.chroma.2013.11.011 · Cited by 39
Self-citationEvaluation of a new low sheath-flow interface for CE-MS: CE and CEC
González‐Ruiz, V., Codesido, S., Far, J., Rudaz, S. L., & Schappler, J. (2016) · Electrophoresis · doi:10.1002/elps.201500523 · Cited by 36
Self-citationRevealing the potential of capillary electrophoresis/mass spectrometry: the tipping point
Gahoual, R., Leize‐Wagner, E., Houzé, P., & François, Y. (2018) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.8238 · Cited by 39
“Indeed, systematic comparison highlighted a sensitivity improvement of at least 100 fold compared to conventional sheath liquid CE-MS analysis [29, 30].”
BackgroundLatosińska, A., Frantzi, M., Vlahou, A., & Mischak, H. (2013) · PROTEOMICS - CLINICAL APPLICATIONS · doi:10.1002/prca.201300038 · Cited by 34
“In this case, improved sensitivity is expected (due to the absence of dilution by the sheath liquid), and this has been reported [44].”
BackgroundBiological mass spectrometry enables spatiotemporal ‘omics: From tissues to cells to organelles
Pade, L. R., Stepler, K. E., Portero, E. P., DeLaney, K., & Nemes, P. (2023) · Mass Spectrometry Reviews · doi:10.1002/mas.21824 · Cited by 30
Křenková, J., Klepárník, K., Luksch, J., & Foret, F. (2019) · Electrophoresis · doi:10.1002/elps.201900049 · Cited by 27
Bertoletti, L., Schappler, J., Colombo, R., Rudaz, S., Haselberg, R., Domínguez-Vega, E., Raimondi, S., Somsen, G. W., & De Lorenzi, E. (2016) · Analytica Chimica Acta · doi:10.1016/j.aca.2016.10.010 · Cited by 25
“[28], has shown particularly useful for the analysis of intact proteins [40e42], offering high sensitivity [43].”
BackgroundSelf-citationHe, H., Tian, M., Hu, L., & Yang, L. (2020) · The Analyst · doi:10.1039/c9an02331c · Cited by 25
Duan, Q., Cao, J., & Zhang, J. (2012) · Analytical Methods · doi:10.1039/c2ay25437a · Cited by 20
González‐Ruiz, V., Codesido, S., Rudaz, S. L., & Schappler, J. (2017) · Electrophoresis · doi:10.1002/elps.201700328 · Cited by 17
Self-citationLiu, B., Wang, W., Gao, T., Huang, L., Fan, H., & Chen, H. (2021) · Analytical Methods · doi:10.1039/d1ay00717c · Cited by 16
Elshamy, Y. S., Strein, T. G., Holland, L., Li, C., DeBastiani, A., Valentine, S. J., Li, P., Lucas, J. A., & Shaffer, T. A. (2022) · Analytical Chemistry · doi:10.1021/acs.analchem.2c02074 · Cited by 14
Liu, J., Zhang, Y., Yuan, F., Chen, H., & Zhang, X. (2014) · Electrophoresis · doi:10.1002/elps.201400334 · Cited by 14
Moreno‐González, D., Haselberg, R., Gámiz‐Gracia, L., García-Campaña, A. M., de Jong, G. J., & Somsen, G. W. (2017) · Journal of Chromatography A · doi:10.1016/j.chroma.2017.09.075 · Cited by 12
“In order to find optimal spray conditions for sheathless MECK-MS, the effect of the applied ESI voltage, capillary tip position, dry gas temperature and dry gas flow was studied (30,34,38).”
BackgroundMethodDevelopment of a novel sheathless CE-ESI-MS interface via a CO2 laser ablated opening
Vermeire, P., Schepdael, A. V., & Petersen, N. J. (2020) · Talanta · doi:10.1016/j.talanta.2020.120853 · Cited by 10
Ferré, S., Drouin, N., González‐Ruiz, V., & Rudaz, S. L. (2021) · Journal of Chromatography A · doi:10.1016/j.chroma.2021.461982 · Cited by 9
Self-citationZhang, F., Hong, J., Xu, W. L., & Qu, F. (2019) · Talanta · doi:10.1016/j.talanta.2019.120183 · Cited by 8
O'Neal, R. M., García, L. D., & Nemes, P. (2026) · Analytical Chemistry · doi:10.1021/acs.analchem.6c01323 · Cited by 7
Risley, J. M., & Chen, D. D. Y. (2017) · Electrophoresis · doi:10.1002/elps.201600545 · Cited by 7
Holtkamp, H. U., Morrow, S. J., Kubanik, M., & Hartinger, C. G. (2018) · Journal of Chromatography A · doi:10.1016/j.chroma.2018.05.036 · Cited by 8
Electrospray Ionization Interface Development for Capillary Electrophoresis-Mass Spectrometry
Risley, J. M., Jong, C. A. G. D., & Chen, D. D. Y. (2016) · Wiley-VCH eBooks · doi:10.1002/9783527693801.ch2 · Cited by 8
CE-MS in Drug Analysis and Bioanalysis
Schappler, J., González‐Ruiz, V., & Rudaz, S. L. (2016) · Wiley-VCH eBooks · doi:10.1002/9783527693801.ch6 · Cited by 8
Self-citationRamautar, R. (2018) · Methods in molecular biology · doi:10.1007/978-1-4939-7643-0_12 · Cited by 6
Pillai, M. S., Paritala, S. T., Shah, R. P., Sharma, N., & Sengupta, P. (2022) · Drug Metabolism Reviews · doi:10.1080/03602532.2022.2125987 · Cited by 4
“mass analyzer for identification of different metabolites where slow scanning rate is a limitation for its multiple uses for faster separation and multiple time analysis (Bonvin et al. 2012).”
MethodCapillary Electrophoresis–Mass Spectrometry Interfacing: Principles and Recent Developments
Naumann, L., Schairer, J., Höchsmann, A., Naghdi, E., & Neusüß, C. (2022) · Wiley eBooks · doi:10.1002/9783527833092.ch1 · Cited by 6
Saïd, N. (2017) · theses.fr (ABES) · doi:10.70675/a41cd9b1z5c4dz4d60z84fdz2821afe2e277 · Cited by 1
A Modular Chip-Based Interface for Sheathless Capillary Electrophoresis−Mass Spectrometry
Schwieger, J., Welters, K., Warias, R., & Belder, D. (2026) · Analytical Chemistry · doi:10.1021/acs.analchem.6c03785
Tascón, M. (2015) · El Servicio de Difusión de la Creación Intelectual (National University of La Plata) · doi:10.35537/10915/45106
Metadata
- Authors
- Bonvin, G., Veuthey, J., Rudaz, S., & Schappler, J.
- Affiliations
- University of Geneva (CH)
- Corresponding author
- Schappler, Julie
- Venue
- ELECTROPHORESIS
- Publisher
- Wiley
- Published
- 2012-02
- Volume
- 33
- Issue
- 4
- Pages
- 552-562
- ISSN
- 0173-0835 (ISSN-L)
- 1522-2683
- OpenAlex
- W2146807700
- Cited by
- 48
- References
- 60
- Citations by year
- 2026: 2 · 2023: 1 · 2022: 3 · 2021: 2 · 2020: 3 · 2019: 3 · 2018: 5 · 2017: 4 · 2016: 7 · 2015: 3 · 2014: 5 · 2013: 5 · 2012: 5
- FWCI
- 2.54
- Type
- journal article
- Language
- en
- Open access
- Locations
- Electrophoresis (publishedVersion)
- PubMed (publishedVersion)
- Archive ouverte UNIGE (University of Geneva) (submittedVersion, cc-by)
- Topics
- Physical Sciences › Chemistry › Spectroscopy › Mass Spectrometry Techniques and Applications
- Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Capillary Electrophoresis Applications
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Electrohydrodynamics and Fluid Dynamics
- Keywords
- capillary electrophoresis-mass spectrometry, electrospray ionization, low molecular weight analytes, pharmaceutical compounds, amphetamine, beta-blockers, sensitivity, repeatability, experimental design
- MeSH terms
- Equipment Design, Sensitivity and Specificity, Electrophoresis, Capillary, Spectrometry, Mass, Electrospray Ionization, Nanotechnology
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.