Evaluation of a sheathless nanospray interface based on a porous tip sprayer for CE‐ESI‐MS coupling
Open accessThe DOI matches its Crossref record; 61 of the 61 references it cites were found in a registry or an index.
Abstract
The hyphenation of capillary electrophoresis (CE) with mass spectrometry (MS) is a powerful method to obtain high efficient, sensitive, and selective analyses. The successful coupling with electrospray ionization (ESI) source requires closed electric circuits for both the CE separation and the ESI processes. A wide range of interfaces has been proposed to satisfy this requirement. Among them, the new high sensitivity porous sprayer based on a porous tip achieves the electric connection by inserting the capillary outlet made of a porous material into an ESI needle filled with a conductive liquid and independently grounded. This device is compatible with the minute flow rates exhibited in CE and therefore makes possible the use of a nano‐electrospray behavior. In this work, this interface was evaluated for hyphenating a CE with a single quadrupole MS instrument for low molecular weight analytes. Investigations aimed at highlighting the most influent parameters thanks to a design of experiments, reaching the best performance in terms of sensitivity and stability. MS signal intensities of various pharmaceutical compounds (e.g. amphetamines, β‐blockers) emphasized high sensitivity and efficiency, while repeatability, expressed as relative standard deviation of corrected heights and areas, was suitable for quantitative purposes (<5%).
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
Analytical Properties of the Nanoelectrospray Ion Source
Wilm, M., & Mann, M. (1996) · Analytical Chemistry · doi:10.1021/ac9509519 · Cited by 1,868
Practical implications of some recent studies in electrospray ionization fundamentals
Cech, N. B., & Enke, C. G. (2001) · Mass Spectrometry Reviews · doi:10.1002/mas.10008 · Cited by 1,435
Electrospray ionization mass spectrometry : fundamentals, instrumentation, and applications
Cole, R. B. (1997) · Wiley eBooks · Cited by 1,140
Handbook of Chemometrics and Qualimetrics
Massart, D. L., Vandeginste, B. G. M., Buydens, L. M. C., Lewi, P. J., Smeyers-Verbeke, J., & Jong, S. D. (1998) · Cited by 1,085
Electrohydrodynamic spraying functioning modes: a critical review
Cloupeau, M., & Prunet-Foch, B. (1994) · Journal of Aerosol Science · doi:10.1016/0021-8502(94)90199-6 · Cited by 794
On-line mass spectrometric detection for capillary zone electrophoresis
Olivares, J. A., Nguyen, N. T., Yonker, C. R., & Smith, R. D. (1987) · Analytical Chemistry · doi:10.1021/ac00135a034 · Cited by 635
CLASSIFICATION OF THE MODES OF EHD SPRAYING
Jaworek, A., & Krupa, A. (1999) · Journal of Aerosol Science · doi:10.1016/s0021-8502(98)00787-3 · Cited by 569
Improved electrospray ionization interface for capillary zone electrophoresis-mass spectrometry
Smith, R. D., Barinaga, C. J., & Udseth, H. R. (1988) · Analytical Chemistry · doi:10.1021/ac00169a022 · Cited by 535
Schmidt, A., Karas, M., & Dülcks, T. (2003) · Journal of the American Society for Mass Spectrometry · doi:10.1016/s1044-0305(03)00128-4 · Cited by 534
Liquid chromatography/mass spectrometry
Covey, T. R., Lee, E. D., Bruins, A. P., & Henion, J. D. (1986) · Analytical Chemistry · doi:10.1021/ac00127a001 · Cited by 469
Nanoelectrospray—More than just a minimized-flow electrospray ionization source
Juraschek, R., Dülcks, T., & Karas, M. (1999) · Journal of the American Society for Mass Spectrometry · doi:10.1016/s1044-0305(98)00157-3 · Cited by 415
Capillary zone electrophoresis-mass spectrometry using an electrospray ionization interface
Smith, R. D., Olivares, J. A., Nguyen, N. T., & Udseth, H. R. (1988) · Analytical Chemistry · doi:10.1021/ac00156a013 · Cited by 393
Moini, M. (2007) · Analytical Chemistry · doi:10.1021/ac0704560 · Cited by 322
Recent advances in capillary electrophoresis/electrospray/mass spectrometry
Banks, J. F. (1997) · ELECTROPHORESIS · doi:10.1002/elps.1150181216 · Cited by 308
Capillary electrophoresis – mass spectrometry: 15 years of developments and applications
Schmitt‐Kopplin, P., & Frommberger, M. (2003) · ELECTROPHORESIS · doi:10.1002/elps.200305659 · Cited by 289
Ramautar, R., Somsen, G. W., & de Jong, G. J. (2009) · ELECTROPHORESIS · doi:10.1002/elps.200800512 · Cited by 280
Loo, J. A., Udseth, H. R., & Smith, R. D. (1989) · Analytical Biochemistry · doi:10.1016/0003-2697(89)90153-x · Cited by 264
Lee, E. D., Mück, W., Henion, J. D., & Covey, T. R. (1988) · Journal of Chromatography A · doi:10.1016/s0021-9673(00)90575-2 · Cited by 209
Chemometrics for experimental design
Naes, T. (1992) · TrAC Trends in Analytical Chemistry · doi:10.1016/0165-9936(92)87013-a · Cited by 202
Maxwell, E. J., & Chen, D. D. Y. (2008) · Analytica Chimica Acta · doi:10.1016/j.aca.2008.06.034 · Cited by 197
Pulsation phenomena during electrospray ionization
Juraschek, R., & Röllgen, F. W. (1998) · International Journal of Mass Spectrometry · doi:10.1016/s1387-3806(98)14025-3 · Cited by 174
Zhang, B., Foret, F., & Karger, B. L. (2000) · Analytical Chemistry · doi:10.1021/ac991150z · Cited by 168
Efficiency of nano-electrospray ionization
El-Faramawy, A., Siu, K. W. M., & Thomson, B. A. (2005) · Journal of the American Society for Mass Spectrometry · doi:10.1016/j.jasms.2005.06.011 · Cited by 168
Busnel, J.-M., Schoenmaker, B., Ramautar, R., Carrasco-Pancorbo, A., Ratnayake, C., Feitelson, J. S., Chapman, J. D., Deelder, A. M., & Mayboroda, O. A. (2010) · Analytical Chemistry · doi:10.1021/ac102159d · Cited by 165
Decoupling CE and ESI for a more robust interface with MS
Maxwell, E. J., Zhong, X., Zhang, H., van Zeijl, N., & Chen, D. D. Y. (2010) · ELECTROPHORESIS · doi:10.1002/elps.200900517 · Cited by 150
Flexing the Electrified Meniscus: The Birth of a Jet in Electrosprays
Marginean, I., Parvin, L., Heffernan, L., & Vértes, Á. (2004) · Analytical Chemistry · doi:10.1021/ac049817r · Cited by 130
Capillary electrophoresis‐electrospray‐mass spectrometry in peptide analysis and peptidomics
Herrero, M., Ibáñez, E., & Cifuentes, A. (2008) · Electrophoresis · doi:10.1002/elps.200700404 · Cited by 126
Jensen, P. K., Paìa-Tolić, L., Hixson, K. K., Martinović, S., Lipton, M. S. W., Anderson, G., Tolić, N., Wong, K., & Smith, R. D. (2000) · Electrophoresis · doi:10.1002/(sici)1522-2683(20000401)21:7<1363::aid-elps1363>3.0.co;2-u · Cited by 125
Recent advances in the application of capillary electrophoresis with mass spectrometric detection
Klampfl, C. W. (2005) · Electrophoresis · doi:10.1002/elps.200500523 · Cited by 119
High-Throughput Microfabricated CE/ESI-MS: Automated Sampling from a Microwell Plate
Zhang, B., Foret, F., & Karger, B. L. (2001) · Analytical Chemistry · doi:10.1021/ac001432v · Cited by 112
Haselberg, R., Ratnayake, C. K., de Jong, G. J., & Somsen, G. W. (2010) · Journal of Chromatography A · doi:10.1016/j.chroma.2010.10.006 · Cited by 109
An experimental study of the electrospraying of water in air at atmospheric pressure
López-Herrera, J. M., Barrero, A., Boucard, A., Loscertales, I. G., & Márquez, M. (2004) · Journal of the American Society for Mass Spectrometry · doi:10.1016/j.jasms.2003.10.018 · Cited by 96
CE with MS detection: A rapidly developing hyphenated technique
Klampfl, C. W. (2009) · Electrophoresis · doi:10.1002/elps.200900088 · Cited by 90
Zamfir, A. D. (2007) · Journal of Chromatography A · doi:10.1016/j.chroma.2007.03.115 · Cited by 87
Shamsi, S. A., & Miller, B. E. (2004) · Electrophoresis · doi:10.1002/elps.200406131 · Cited by 84
Automated orthogonal control system for electrospray ionization
Valaskovic, G. A., Murphy, J. P., & Lee, M. S. (2004) · Journal of the American Society for Mass Spectrometry · doi:10.1016/j.jasms.2004.04.033 · Cited by 73
Issaq, H. J., Janini, G. M., Chan, K. C., & Veenstra, T. (2004) · Journal of Chromatography A · doi:10.1016/s0021-9673(04)01475-x · Cited by 68
CE‐TOF/MS: Fundamental concepts, instrumental considerations and applications
Staub, A., Schappler, J., Rudaz, S. L., & Veuthey, J. (2009) · Electrophoresis · doi:10.1002/elps.200800782 · Cited by 65
Self-citationMokaddem, M., Gareil, P., Belgaied, J., & Varenne, A. (2008) · Electrophoresis · doi:10.1002/elps.200700880 · Cited by 63
A sheath‐flow nanospray interface for capillary electrophoresis/mass spectrometry
Liu, C. C., Zhang, J., & Dovic̀hi, N. J. (2004) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.1769 · Cited by 59
A novel nanospray capillary zone electrophoresis/mass spectrometry interface
Hsieh, F., Baronas, E., Muir, C., & Martin, S. A. (1999) · Rapid Communications in Mass Spectrometry · doi:10.1002/(sici)1097-0231(19990115)13:1<67::aid-rcm453>3.0.co;2-f · Cited by 57
Geiser, L., Rudaz, S. L., & Veuthey, J. (2003) · Electrophoresis · doi:10.1002/elps.200305564 · Cited by 56
Self-citationSchappler, J., Nicoli, R., Nguyen, D. T. ‐., Rudaz, S. L., Veuthey, J., & Guillarme, D. (2008) · Talanta · doi:10.1016/j.talanta.2008.11.029 · Cited by 55
Self-citationFont, G., Ruiz, M.-J., Fernández-Franzón, M., & Picó, Y. (2008) · Electrophoresis · doi:10.1002/elps.200700669 · Cited by 51
Asymmetrical Emitter Geometries for Increased Range of Stable Electrospray Flow Rates
Maxwell, E. J., Zhong, X., & Chen, D. D. Y. (2010) · Analytical Chemistry · doi:10.1021/ac1017953 · Cited by 51
Schappler, J., Guillarme, D., Prat, J., Veuthey, J., & Rudaz, S. L. (2008) · Electrophoresis · doi:10.1002/elps.200700464 · Cited by 49
Self-citationLiquid chromatography/microspray mass spectrometry for bacterial investigations
Krishnamurthy, T., Davis, M. T., Stahl, D. C., & Lee, T. D. (1999) · Rapid Communications in Mass Spectrometry · doi:10.1002/(sici)1097-0231(19990115)13:1<15::aid-rcm439>3.0.co;2-a · Cited by 49
Mokaddem, M., Gareil, P., Belgaied, J., & Varenne, A. (2009) · ELECTROPHORESIS · doi:10.1002/elps.200800480 · Cited by 45
Experimental Design: A Chemometric Approach
Reece, J. E., Deming, S. N., & Morgan, S. L. (1994) · The American Statistician · doi:10.2307/2684279 · Cited by 45
Nilsson, S. L., Bylund, D., Jörntén‐Karlsson, M., Petersson, P., & Markides, K. E. (2004) · Electrophoresis · doi:10.1002/elps.200305937 · Cited by 40
Schappler, J., Guillarme, D., Prat, J., Veuthey, J., & Rudaz, S. L. (2007) · Electrophoresis · doi:10.1002/elps.200700012 · Cited by 37
Self-citationEnhanced method performances for conventional and chiral CE‐ESI/MS analyses in plasma
Schappler, J., Guillarme, D., Prat, J., Veuthey, J., & Rudaz, S. L. (2006) · Electrophoresis · doi:10.1002/elps.200500805 · Cited by 35
Self-citationChen, Y., Tseng, M., & Her, G. (2005) · Electrophoresis · doi:10.1002/elps.200410159 · Cited by 28
Tseng, M., Chen, Y., & Her, G. (2004) · Electrophoresis · doi:10.1002/elps.200305907 · Cited by 28
18 Coupling CE and microchip-based devices with mass spectrometry
Schappler, J., Veuthey, J., & Rudaz, S. L. (2008) · Separation science and technology · doi:10.1016/s0149-6395(07)00018-9 · Cited by 26 · cited 1×
“Abbreviations: DOE, design of experiments; HSPS, high sensitivity porous sprayer; iPrOH, isopropanol; MA, methamphetamine; MA-d5, methamphetamined5; MDMA, methylenedioxymethamphetamine; MDEA, methylenedioxyethylamphetamine; MeOH, methanol; MTD, methadone; MTD-d3, methadone-d3; Von, ESI onset voltage tion techniques, s…”
BackgroundSelf-citationLiu, C. C., Alary, J., Vollmerhaus, P. J., & Kadkhodayan, M. (2005) · Electrophoresis · doi:10.1002/elps.200410133 · Cited by 23
Matsunaga, H., & Haginaka, J. (2001) · Electrophoresis · doi:10.1002/1522-2683(200109)22:15<3316::aid-elps3316>3.0.co;2-r · Cited by 14
Hashimoto, M., Ishihama, Y., Tomita, M., & Soga, T. (2007) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.3256 · Cited by 13
Liquid Chromatography/Mass Spectrometry
Klink, F. E. (2010) · Encyclopedia of Analytical Chemistry · doi:10.1002/9780470027318.a6013.pub2 · Cited by 7
Liquid Chromatography-Mass Spectrometry
Ohara, S. (2011) · Encyclopedia of Astrobiology · doi:10.1007/978-3-642-11274-4_896 · Cited by 1
Research works printed but not linked: 4
- Haleem J. I., 2004, J. Chromatogr. A, 1053, 37
- Lewis, G. A., 1999, Pharm. Experimental Design
- Morgan, E., 1991, Chemometrics: Experimental Design
- Kerbarle, P., 1997, Electrospray Ionization Mass Spectrometry: Fundamentals, Instrumentation and Applications, 107
Cited by
Harstad, R. K., Johnson, A. C., Weisenberger, M. M., & Bowser, M. T. (2016) · Analytical Chemistry · doi:10.1021/acs.analchem.5b04125 · Cited by 158
Haselberg, R., de Jong, G. J., & Somsen, G. W. (2013) · Analytical Chemistry · doi:10.1021/ac303158f · Cited by 149
Stalmach, A., Albalat, A., Mullen, W., & Mischak, H. (2013) · ELECTROPHORESIS · doi:10.1002/elps.201200708 · Cited by 117
Bonvin, G., Schappler, J., & Rudaz, S. L. (2012) · Journal of Chromatography A · doi:10.1016/j.chroma.2012.07.019 · Cited by 127
Self-citationRecent trends of capillary electrophoresis‐mass spectrometry in proteomics research
Gomes, F. P., & Yates, J. R. (2019) · Mass Spectrometry Reviews · doi:10.1002/mas.21599 · Cited by 112
Metadata
- Authors
- Bonvin, G., Veuthey, J., Rudaz, S., & Schappler, J.
- Affiliations
- University of Geneva (CH)
- Corresponding author
- Schappler, Julie
- Venue
- ELECTROPHORESIS
- Publisher
- Wiley
- Published
- 2012-02
- Volume
- 33
- Issue
- 4
- Pages
- 552-562
- ISSN
- 0173-0835 (ISSN-L)
- 1522-2683
- OpenAlex
- W2146807700
- Cited by
- 48
- References
- 60
- Citations by year
- 2026: 2 · 2023: 1 · 2022: 3 · 2021: 2 · 2020: 3 · 2019: 3 · 2018: 5 · 2017: 4 · 2016: 7 · 2015: 3 · 2014: 5 · 2013: 5 · 2012: 5
- FWCI
- 2.54
- Type
- journal article
- Language
- en
- Open access
- Locations
- Electrophoresis (publishedVersion)
- PubMed (publishedVersion)
- Archive ouverte UNIGE (University of Geneva) (submittedVersion, cc-by)
- Topics
- Physical Sciences › Chemistry › Spectroscopy › Mass Spectrometry Techniques and Applications
- Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Capillary Electrophoresis Applications
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Electrohydrodynamics and Fluid Dynamics
- Keywords
- capillary electrophoresis-mass spectrometry, electrospray ionization, low molecular weight analytes, pharmaceutical compounds, amphetamine, beta-blockers, sensitivity, repeatability, experimental design
- MeSH terms
- Equipment Design, Sensitivity and Specificity, Electrophoresis, Capillary, Spectrometry, Mass, Electrospray Ionization, Nanotechnology
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.