Capillary electrophoresis‐mass spectrometry methods for tryptic peptide mapping of therapeutic antibodies
The DOI matches its Crossref record.
Abstract
Tryptic peptide mapping is routinely used in the biotech industry to confirm primary sequence, cell line stability, and to analyze posttranslational modifications. Peptide analysis is generally done by reverse phase liquid chromatography with UV or mass spectrometric detection. This method provides excellent resolution and sequence coverage. However, traditional methods are slow, and generally cannot detect small, hydrophilic peptides due to coelution with the column void volume. In this work, complementary CE‐MS peptide analysis methods have been developed. The analyses are performed on a traditional CE‐MS instrument with a sheath interface, and also on a novel sheathless interface that promises improved resolution and limit of detection. The methods were performed on a tryptic digest of a therapeutic monoclonal antibody for which LC‐MS detects 97% sequence coverage. The 3% not covered consists of 11 peptides containing three amino acids or fewer, including two in the critical complementarity binding domain. Without further processing, the same tryptic digest was analyzed by CE‐MS. Separation and detection of the 11 small peptides was achieved on CE‐MS systems with both interfaces. The sheathless system produced better peak capacity and gave mass spectra with significantly less noise, while the sheath system proved to have better repeatability.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Fekete, S., Guillarme, D., Sandra, P., & Sandra, K. (2016) · Analytical Chemistry · doi:10.1021/acs.analchem.5b04561 · Cited by 258
Glycan analysis of therapeutic glycoproteins
Zhang, L., Luo, S., & Zhang, B. (2016) · mAbs · doi:10.1080/19420862.2015.1117719 · Cited by 207
Haselberg, R., de Jong, G. J., & Somsen, G. W. (2013) · Analytical Chemistry · doi:10.1021/ac303158f · Cited by 149
Redman, E. A., Batz, N. G., Mellors, J. S., & Ramsey, J. M. (2015) · Analytical Chemistry · doi:10.1021/ac503964j · Cited by 136
Recent trends of capillary electrophoresis‐mass spectrometry in proteomics research
Gomes, F. P., & Yates, J. R. (2019) · Mass Spectrometry Reviews · doi:10.1002/mas.21599 · Cited by 112
Metadata
- Authors
- Whitmore, C. D., & Gennaro, L. A.
- Venue
- ELECTROPHORESIS
- Publisher
- Wiley
- Published
- 2012-06
- Volume
- 33
- Issue
- 11
- Pages
- 1550-1556
- ISSN
- 0173-0835 (ISSN-L)
- 1522-2683
- OpenAlex
- W2051054515
- Cited by
- 49
- References
- 0
- FWCI
- 3.66
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Capillary electrophoresis‐mass spectrometry methods for tryptic peptide mapping of therapeutic antibodies. https://app.cochat.ai/papers/10.1002/elps.201200066
- The paper
- Whitmore, C. D., & Gennaro, L. A. (2012). Capillary electrophoresis‐mass spectrometry methods for tryptic peptide mapping of therapeutic antibodies. ELECTROPHORESIS. https://doi.org/10.1002/elps.201200066
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.