Integrated Microfluidic Capillary Electrophoresis-Electrospray Ionization Devices with Online MS Detection for the Separation and Characterization of Intact Monoclonal Antibody Variants
The DOI matches its Crossref record; 46 of the 46 references it cites were found in a registry or an index.
Abstract
Here, we demonstrate an integrated microfluidic capillary electrophoresis-electrospray ionization (CE-ESI) device for the separation of intact monoclonal antibody charge variants with online mass spectrometric (MS) identification. The need for dynamic coating and zwitterionic background electrolyte (BGE) additives has been eliminated by utilizing surface chemistry within the device channels to control analyte adsorption and electroosmotic flow (EOF) while maintaining separation efficiency. The effectiveness of this strategy was illustrated with the separation of charge variants of Infliximab. Three major species corresponding to C-terminal lysine variants were separated with an average resolution of 0.80 and identified by mass difference. In addition to the lysine variants, masses were determined for minor acidic and basic species. The separation of these variants prior to MS analysis facilitated the identification of glycosylation patterns for each of the variants. The general applicability of this method was demonstrated by analyzing two additional monoclonal antibody species: an IgG2 antibody and an IgG1 antibody conjugate. The IgG2 proved to have similar modifications to Infliximab with lower relative abundances of the lysine variants. Analysis of the IgG1 drug conjugate further exemplified the advantages of MS detection; differences in the extent of antibody conjugation were detectable despite limited CE resolution. The CE-ESI-MS methodology described here is a rapid and generic strategy for the separation of intact mAb charge variants and facilitates the identification of variants through MS detection.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The use of microchip CE-MS has also been demonstrated for the separation of intact monoclonal antibody variants where fast analysis was achieved (~ 4 min)137.”
From Recent trends of capillary electrophoresis‐mass spectrometry in proteomics research (2019) · cites this paper as [137]
Citations
Cites
The Impact of Glycosylation on the Biological Function and Structure of Human Immunoglobulins
Arnold, J. N., Wormald, M. R., Sim, R. B., Rudd, P. M., & Dwek, R. A. (2007) · Annual Review of Immunology · doi:10.1146/annurev.immunol.25.022106.141702 · Cited by 1,307
Jacobson, S. C., Hergenroder, R., Koutny, L. B., Warmack, R. J., & Ramsey, J. M. (1994) · Analytical Chemistry · doi:10.1021/ac00079a028 · Cited by 669
Self-citationHeterogeneity of Monoclonal Antibodies
Liu, H., Gaza-Bulseco, G., Faldu, D., Chumsae, C., & Sun, J. (2008) · Journal of Pharmaceutical Sciences · doi:10.1002/jps.21180 · Cited by 481
High-Speed Separations on a Microchip
Jacobson, S. C., Hergenroder, R., Koutny, L. B., & Ramsey, J. M. (1994) · Analytical Chemistry · doi:10.1021/ac00079a029 · Cited by 450
Self-citationMass spectrometry for structural characterization of therapeutic antibodies
Zhang, Z., Pan, H., & Chen, X. (2009) · Mass Spectrometry Reviews · doi:10.1002/mas.20190 · Cited by 316
Non-covalent capillary coatings for protein separations in capillary electrophoresis
Lucy, C. A., MacDonald, A. M., & Gulcev, M. D. (2008) · Journal of Chromatography A · doi:10.1016/j.chroma.2007.10.114 · Cited by 299
Disentangling electrospray spectra with maximum entropy
Ferrige, A. G., Seddon, M. J., Green, B. N., Jarvis, S. A., Skilling, J., & Staunton, J. (1992) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.1290061115 · Cited by 261
Mellors, J. S., Jorabchi, K., Smith, L. M., & Ramsey, J. M. (2010) · Analytical Chemistry · doi:10.1021/ac902218y · Cited by 235
Self-citationMicrofluidic Devices for Electrokinetically Driven Parallel and Serial Mixing
Jacobson, S. C., McKnight, T. E., & Ramsey, J. M. (1999) · Analytical Chemistry · doi:10.1021/ac990576a · Cited by 233
Self-citationFormation of Pyroglutamic Acid from N-Terminal Glutamic Acid in Immunoglobulin Gamma Antibodies
Chelius, D., Jing, K., Lueras, A., Rehder, D. S., Dillon, T. M., Vizel, A., Rajan, R. S., Li, T., Treuheit, M. J., & Bondarenko, P. V. (2006) · Analytical Chemistry · doi:10.1021/ac051827k · Cited by 200
Research works printed but not linked: 3
- Haselberg R., 2013, Anal. Biochem., 85, 2289
- Berger S. J., 2008, Efficiently Comparing Batches of an Intact Monoclonal Antibody Using the Biopharmalynx Software Package
- Shion H., 2013, Structural Comparison of Infliximab and a Biosimilar via Subunit Analysis Using the Waters Biopharmaceutical Platform with UNIFI
Cited by
Fekete, S., Guillarme, D., Sandra, P., & Sandra, K. (2016) · Analytical Chemistry · doi:10.1021/acs.analchem.5b04561 · Cited by 258
Analytical Techniques for Metabolomic Studies: A Review
Segers, K., Declerck, S., Mangelings, D., Heyden, Y. V., & Eeckhaut, A. V. (2019) · Bioanalysis · doi:10.4155/bio-2019-0014 · Cited by 225
Sonker, M., Sahore, V., & Woolley, A. T. (2017) · Analytica Chimica Acta · doi:10.1016/j.aca.2017.07.043 · Cited by 171
“[53] reported an integrated μCE-electrospray ionization device for separation of monoclonal antibodies (mAbs).”
BackgroundCapillary Electrophoresis Separations of Glycans
Lu, G., Crihfield, C. L., Gattu, S., Veltri, L. M., & Holland, L. A. (2018) · Chemical Reviews · doi:10.1021/acs.chemrev.7b00669 · Cited by 174
Biochemical analysis on microfluidic chips
Wu, J., He, Z., Chen, Q., & Lin, J. (2016) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2016.03.013 · Cited by 162
“to separate intact monoclonal antibody charge variants with online MS identification [108].”
Background
Metadata
- Authors
- Redman, E. A., Batz, N. G., Mellors, J. S., & Ramsey, J. M.
- Affiliations
- University of North Carolina at Chapel Hill (US)
- Corresponding author
- Ramsey, J. Michael
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2015-01-29
- Volume
- 87
- Issue
- 4
- Pages
- 2264-2272
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2315996892
- Cited by
- 136
- References
- 46
- Citations by year
- 2026: 6 · 2025: 5 · 2024: 8 · 2023: 11 · 2022: 11 · 2021: 15 · 2020: 14 · 2019: 13 · 2018: 13 · 2017: 19 · 2016: 17 · 2015: 4
- FWCI
- 8.79
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Analytical Chemistry (publishedVersion)
- PubMed (publishedVersion)
- Funders
- Center for Biomedical Microdevices, University of North Carolina, Chapel Hill
- National Institute of General Medical Sciences (5R01GM066018-11)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Capillary Electrophoresis Applications
- Physical Sciences › Chemistry › Spectroscopy › Mass Spectrometry Techniques and Applications
- Life Sciences › Immunology and Microbiology › Immunology › Biosimilars and Bioanalytical Methods
- Keywords
- microfluidic capillary electrophoresis, infliximab, glycosylation patterns, electroosmotic flow control, surface chemistry, IgG2 antibodies, antibody conjugates, on-line mass spectrometry
- MeSH terms
- Immunoglobulin G, Electrophoresis, Capillary, Spectrometry, Mass, Electrospray Ionization, Microfluidic Analytical Techniques
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Integrated Microfluidic Capillary Electrophoresis-Electrospray Ionization Devices with Online MS Detection for the Separation and Characterization of Intact Monoclonal Antibody Variants. https://app.cochat.ai/papers/10.1021/ac503964j
- The paper
- Redman, E. A., Batz, N. G., Mellors, J. S., & Ramsey, J. M. (2015). Integrated Microfluidic Capillary Electrophoresis-Electrospray Ionization Devices with Online MS Detection for the Separation and Characterization of Intact Monoclonal Antibody Variants. Analytical Chemistry. https://doi.org/10.1021/ac503964j
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.