Static coatings for the analysis of intact monoclonal antibody drugs by capillary zone electrophoresis
The DOI matches its Crossref record.
Abstract
This work reports on the investigation of the optimal conditions associated with good isoform resolution, minimized adsorption, and acceptable repeatability for the analysis of intact monoclonal antibodies. To this end, various static capillary coatings were evaluated, and major trends were observed. For a positively charged coating, a low EOF mobility value was the main criterion for satisfactory resolution. For neutral coatings, adsorption was the main concern. If the coating does not fully cover the surface silanols, electrostatic interactions tend to decrease protein recovery through irreversible adsorption. The influence of the BGE p H was also investigated, as the resolution of monoclonal antibody isoforms is driven by their charge difference. The nature and concentration of the BGE were proven to be important, as an ampholytic compound such as ε‐aminocaproic acid was found to decrease adsorption compared with ammonium acetate. With the optimal conditions determined during method development, a complete investigation according to four criteria, i.e. migration time, separation efficiency, EOF mobility, and protein recovery, did not present evidence of any adsorption. Finally, the repeatability and intermediate precision were assessed, and low variability was demonstrated with an RSD less than 1.3% for the main peak migration time.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Fekete, S., Guillarme, D., Sandra, P., & Sandra, K. (2016) · Analytical Chemistry · doi:10.1021/acs.analchem.5b04561 · Cited by 258
Redman, E. A., Batz, N. G., Mellors, J. S., & Ramsey, J. M. (2015) · Analytical Chemistry · doi:10.1021/ac503964j · Cited by 136
Jooß, K., Hühner, J., Kiessig, S., Moritz, B., & Neusüß, C. (2017) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-017-0542-0 · Cited by 79
Biacchi, M., Said, N., Beck, A., Leize-Wagner, E., & François, Y.-N. (2017) · Journal of Chromatography A · doi:10.1016/j.chroma.2017.02.064 · Cited by 41
Metadata
- Authors
- Gassner, A., Rudaz, S., & Schappler, J.
- Venue
- ELECTROPHORESIS
- Publisher
- Wiley
- Published
- 2013-08-13
- Volume
- 34
- Issue
- 18
- Pages
- 2718-2724
- ISSN
- 0173-0835 (ISSN-L)
- 1522-2683
- OpenAlex
- W2073396241
- Cited by
- 36
- References
- 0
- FWCI
- 2.13
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Static coatings for the analysis of intact monoclonal antibody drugs by capillary zone electrophoresis. https://app.cochat.ai/papers/10.1002/elps.201300070
- The paper
- Gassner, A., Rudaz, S., & Schappler, J. (2013). Static coatings for the analysis of intact monoclonal antibody drugs by capillary zone electrophoresis. ELECTROPHORESIS. https://doi.org/10.1002/elps.201300070
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.