The DOI matches its Crossref record; 38 of the 38 references it cites were found in a registry or an index.
Two-dimensional capillary zone electrophoresis–mass spectrometry for the characterization of intact monoclonal antibody charge variants, including deamidation products
Abstract
Capillary zone electrophoresis (CZE) is a powerful tool that is progressively being applied for the separation of monoclonal antibody (mAb) charge variants. Mass spectrometry (MS) is the desired detection method concerning identification of mAb variants. In biopharmaceutical applications, there exist optimized and validated electrolyte systems for mAb variant quantification. However, these electrolytes interfere greatly with the electrospray ionization (ESI) process. Here, a heart-cut CZE-CZE-MS setup with an implemented mechanical four-port valve interface was developed that used a generic ε-aminocaproic acid based background electrolyte in the first dimension and acetic acid in the second dimension. Interference-free, highly precise mass data (deviation less than 1 Da) of charge variants of trastuzumab, acting as model mAb system, were achieved. The mass accuracy obtained (low parts per million range) is discussed regarding both measured and calculated masses. Deamidation was detected for the intact model antibody, and related mass differences were significantly confirmed on the deglycosylated level. The CZE-CZE-MS setup is expected to be applicable to a variety of antibodies and electrolyte systems. Thus, it has the potential to become a compelling tool for MS characterization of antibody variants separated in ESI-interfering electrolytes. Graphical Abstract Two-dimensional capillary zone electrophoresis mass spectrometry for the characterization of intact monoclonal antibody (mAb) charge variants. A generic, but highly electrospray-interfering electrolyte system was used as first dimension for mAb charge variant separation and coupled to a volatile electrolyte system as second dimension via a four-port nanoliter valve. In this way, interference-free and precise mass spectrometric data of separated mAb charge variants, including deamidation products, were obtained.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“CE–MS has been used to determine the purity and the stability of proteins in drug discovery23.”
From Recent trends of capillary electrophoresis‐mass spectrometry in proteomics research (2019) · cites this paper as [23]
In the citing paper
“Jooss and co-workers demonstrated the power of CZE-CZE-MS for the characterization of intact monoclonal antibody charge variants23.”
From Recent trends of capillary electrophoresis‐mass spectrometry in proteomics research (2019) · cites this paper as [23]
Citations
Cites
Carbon Isotopes in Photosynthesis
O'Leary, M. H. (1988) · BioScience · doi:10.2307/1310735 · Cited by 2,475
Isotopic compositions of the elements 2013 (IUPAC Technical Report)
Meija, J., Coplen, T. B., Berglund, M., Brand, W. A., De Bièvre, P., Gröning, M., Holden, N. E., Irrgeher, J., Loss, R. D., Walczyk, T., et al. (2016) · Pure and Applied Chemistry · doi:10.1515/pac-2015-0503 · Cited by 1,677
Characterization of Therapeutic Antibodies and Related Products
Beck, A., Wagner-Rousset, E., Ayoub, D., Van Dorsselaer, A., & Sanglier-Cianférani, S. (2013) · Analytical Chemistry · doi:10.1021/ac3032355 · Cited by 587
Identification of multiple sources of charge heterogeneity in a recombinant antibody
Harris, R. J., Kabakoff, B., Macchi, F. D., Shen, F. J., Kwong, M., Andya, J. D., Shire, S. J., Bjork, N., Totpal, K., & Chen, A. B. (2001) · Journal of Chromatography B: Biomedical Sciences and Applications · doi:10.1016/s0378-4347(00)00548-x · Cited by 500
Fekete, S., Guillarme, D., Sandra, P., & Sandra, K. (2016) · Analytical Chemistry · doi:10.1021/acs.analchem.5b04561 · Cited by 258
Visser, J., Feuerstein, I., Stangler, T., Schmiederer, T., Fritsch, C., & Schiestl, M. (2013) · BioDrugs · doi:10.1007/s40259-013-0036-3 · Cited by 185
Reusch, D., Haberger, M., Maier, B., Maier, M., Kloseck, R., Zimmermann, B., Hook, M., Szabo, Z., Tep, S., Wegstein, J., et al. (2015) · mAbs · doi:10.4161/19420862.2014.986000 · Cited by 168
In vitro and in vivo modifications of recombinant and human IgG antibodies
Liu, H., Ponniah, G., Zhang, H.-M., Nowak, C., Neill, A., Gonzalez-Lopez, N., Patel, R., Cheng, G., Kita, A. Z., & Andrien, B. (2014) · mAbs · doi:10.4161/mabs.29883 · Cited by 168
Palmisano, G., Melo-Braga, M. N., Engholm-Keller, K., Parker, B. L., & Larsen, M. R. (2012) · Journal of Proteome Research · doi:10.1021/pr2011268 · Cited by 168
Sandra, K., Vandenheede, I., & Sandra, P. J. F. (2013) · Journal of Chromatography A · doi:10.1016/j.chroma.2013.11.057 · Cited by 164
Cited by
Mass spectrometry approaches to glycomic and glycoproteomic analyses
Ruhaak, L. R., Xu, G., Li, Q., Goonatilleke, E., & Lebrilla, C. B. (2018) · Chemical Reviews · doi:10.1021/acs.chemrev.7b00732 · Cited by 395
Capillary Electrophoresis: Trends and Recent Advances
Voeten, R. L. C., Ventouri, I. K., Haselberg, R., & Somsen, G. W. (2018) · Analytical Chemistry · doi:10.1021/acs.analchem.8b00015 · Cited by 315
Stolz, A., Jooß, K., Höcker, O., Römer, J., Schlecht, J., & Neusüß, C. (2019) · ELECTROPHORESIS · doi:10.1002/elps.201800331 · Cited by 214
Self-citationGupta, S., Jiskoot, W., Schöneich, C., & Rathore, A. S. (2021) · Journal of Pharmaceutical Sciences · doi:10.1016/j.xphs.2021.11.024 · Cited by 156
Dai, J., Lamp, J., Xia, Q., & Zhang, Y. (2018) · Analytical Chemistry · doi:10.1021/acs.analchem.7b04608 · Cited by 123
Metadata
- Authors
- Jooß, K., Hühner, J., Kiessig, S., Moritz, B., & Neusüß, C.
- Affiliations
- Helmholtz Munich (DE)
- Hochschule Aalen (DE)
- F. Hoffmann-La Roche AG (CH)
- Corresponding author
- Neusüß, Christian
- Venue
- Analytical and Bioanalytical Chemistry
- Published
- 2017-08-12
- Volume
- 409
- Issue
- 26
- Pages
- 6057-6067
- ISSN
- 1618-2642 (ISSN-L)
- 1618-2650
- OpenAlex
- W2744624103
- Cited by
- 79
- References
- 38
- Citations by year
- 2026: 2 · 2025: 5 · 2024: 3 · 2023: 7 · 2022: 6 · 2021: 16 · 2020: 7 · 2019: 15 · 2018: 17 · 2017: 1
- FWCI
- 4.93
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Analytical and Bioanalytical Chemistry (publishedVersion)
- PubMed (publishedVersion)
- Site cant be reached (submittedVersion)
- PuSH - Publication Server of Helmholtz Zentrum München (submittedVersion)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Capillary Electrophoresis Applications
- Physical Sciences › Chemistry › Spectroscopy › Mass Spectrometry Techniques and Applications
- Life Sciences › Immunology and Microbiology › Immunology › Biosimilars and Bioanalytical Methods
- Keywords
- deamidation, trastuzumab, mass accuracy, biopharmaceutical characterization
- MeSH terms
- Trastuzumab, Antineoplastic Agents, Immunological, Amides, Antibodies, Monoclonal, Electrolytes, Equipment Design, Glycosylation, Aminocaproic Acid, Electrophoresis, Capillary, Spectrometry, Mass, Electrospray Ionization, Static Electricity
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Two-dimensional capillary zone electrophoresis–mass spectrometry for the characterization of intact monoclonal antibody charge variants, including deamidation products. https://app.cochat.ai/papers/10.1007/s00216-017-0542-0
- The paper
- Jooß, K., Hühner, J., Kiessig, S., Moritz, B., & Neusüß, C. (2017). Two-dimensional capillary zone electrophoresis–mass spectrometry for the characterization of intact monoclonal antibody charge variants, including deamidation products. Analytical and Bioanalytical Chemistry. https://doi.org/10.1007/s00216-017-0542-0
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.