Determination of estrogens in environmental water samples using 1,3‐dipentylimidazolium hexafluorophosphate ionic liquid as extraction solvent in dispersive liquid–liquid microextraction
The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Abstract
In this work, the potential of a symmetric dialkyl‐substituted ionic liquid (IL), 1,3‐dipenthylimidazolium hexafluorophosphate ([PPI m][PF6]), as extraction solvent in dispersive liquid–liquid microextraction (DLLME) has been studied for the analysis of a group of three natural (estriol, 17β‐estradiol, and 17α‐estradiol) and four synthetic (17α‐ethynylestradiol, diethylstibestrol, dienestrol, and hexestrol) estrogenic compounds as well as one mycotoxin with estrogenic activity (zearalenone) in different types of water samples (Milli‐Q, mineral, and wastewater). Separation, determination, and quantification were developed by HPLC‐DAD and a fluorescence detector (FD) connected in series. Factors influencing the IL‐DLLME procedure (sample pH, amount of IL, type and volume of disperser solvent, ionic strength, and assistance of vortex agitation) were investigated and optimized by means of a step‐by‐step approach. Once the optimum extraction conditions were established (10 mL of water at pH 8, 60 mg of [PPI m][PF6], 500 μL of ACN as disperser solvent and vortex agitation for 1 min), the calibration curves of the whole method (IL‐DLLME‐HPLC‐DAD/FD) were obtained and precision and accuracy were evaluated. It was demonstrated that the developed methodology was repeatable, accurate, and selective with limits of detection in the 0.30–0.57 μg/L and 13.8–37.1 μg/L range for FD and DAD, respectively. Relative recovery values were higher than 85% for the different types of water samples and the S tudent's t test demonstrated that there were not significant differences between the added and the found concentration.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Determination of organic compounds in water using dispersive liquid–liquid microextraction
Rezaee, M., Assadi, Y., Milani Hosseini, M.-R., Aghaee, E., Ahmadi, F., & Berijani, S. (2006) · Journal of Chromatography A · doi:10.1016/j.chroma.2006.03.007 · Cited by 3,402
Evolution of dispersive liquid–liquid microextraction method
Rezaee, M., Yamini, Y., & Faraji, M. (2010) · Journal of Chromatography A · doi:10.1016/j.chroma.2009.11.088 · Cited by 971
Temperature-controlled ionic liquid dispersive liquid phase micro-extraction
Zhou, Q., Bai, H., Xie, G., & Xiao, J. (2008) · Journal of Chromatography A · doi:10.1016/j.chroma.2007.10.103 · Cited by 303
Liu, Y., Zhao, E., Zhu, W., Gao, H., & Zhou, Z. (2009) · Journal of Chromatography A · doi:10.1016/j.chroma.2008.11.076 · Cited by 301
Dispersive liquid-liquid microextraction for determination of organic analytes
Herrera-Herrera, A. V., Asensio-Ramos, M., Hernández-Borges, J., & Rodríguez-Delgado, M. Á. (2010) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2010.03.016 · Cited by 294
Self-citationIonic liquids in dispersive liquid-liquid microextraction
Trujillo-Rodríguez, M. J., Rocío-Bautista, P., Pino, V., & Afonso, A. M. (2013) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2013.06.008 · Cited by 276
Recent development and applications of dispersive liquid–liquid microextraction
Yan, H., & Wang, H. (2013) · Journal of Chromatography A · doi:10.1016/j.chroma.2013.04.053 · Cited by 256
Ravelo-Pérez, L. M., Hernández-Borges, J., Asensio-Ramos, M., & Rodríguez-Delgado, M. Á. (2009) · Journal of Chromatography A · doi:10.1016/j.chroma.2009.08.012 · Cited by 156
Self-citationChang, C.-C., & Huang, S.-D. (2010) · Analytica Chimica Acta · doi:10.1016/j.aca.2010.01.003 · Cited by 152
Ionic liquid based dispersive liquid–liquid microextraction of aromatic amines in water samples
Fan, Y. C., Hu, Z. L., Chen, M. L., Tu, C. S., & Zhu, Y. (2008) · Chinese Chemical Letters · doi:10.1016/j.cclet.2008.05.024 · Cited by 70
Cited by
Non-conventional solvents in liquid phase microextraction and aqueous biphasic systems
An, J., Trujillo-Rodríguez, M. J., Pino, V., & Anderson, J. L. (2017) · Journal of Chromatography A · doi:10.1016/j.chroma.2017.04.012 · Cited by 128
Ten years of dispersive liquid–liquid microextraction and derived techniques
Campillo, N., Viñas, P., Šandrejová, J., & Andruch, V. (2017) · Applied Spectroscopy Reviews · doi:10.1080/05704928.2016.1224240 · Cited by 102
Moon, Y., & Myung, S. (2016) · Bulletin of the Korean Chemical Society · doi:10.1002/bkcs.11016 · Cited by 16
Hang, Q., Lou, Y., Yin, H., Yuan, Y., & Xiong, Z. (2024) · Microchimica Acta · doi:10.1007/s00604-024-06546-3 · Cited by 12
Metadata
- Authors
- Socas‐Rodríguez, B., Hernández‐Borges, J., Asensio‐Ramos, M., Herrera‐Herrera, A. V., Palenzuela, J. A., & Rodríguez‐Delgado, M. Á.
- Venue
- ELECTROPHORESIS
- Publisher
- Wiley
- Published
- 2014-07-24
- Volume
- 35
- Issue
- 17
- Pages
- 2479-2487
- ISSN
- 0173-0835 (ISSN-L)
- 1522-2683
- OpenAlex
- W1766993650
- Cited by
- 29
- References
- 11
- FWCI
- 5.50
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.