CoChat

Heart‐cut nano‐LC–CZE–MS for the characterization of proteins on the intact level

The DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.

Abstract

Multidimensional separation techniques play an increasingly important role in separation science, especially for the analysis of complex samples such as proteins. The combination of reversed‐phase liquid chromatography in the nanoscale and CZE is especially beneficial due to their nearly orthogonal separation mechanism and well‐suited geometries/dimensions. Here, a heart‐cut nano‐LC–CZE–MS setup was developed utilizing for the first time a mechanical 4‐port valve as LC–CE interface. A model protein mixture containing four different protein species was first separated by nano LC followed by a heart‐cut transfer of individual LC peaks and subsequent CZE–MS analysis. In the CZE dimension, various glycoforms of one protein species were separated. Improved separation capabilities were achieved compared to the 1D methods, which was exemplarily shown for ribonuclease B and its different glycosylated forms. LODs in the lower μg/mL range were determined, which are considerably lower compared to traditional CZE–MS. In addition, this study represents the first application of an LC–CE–MS system for intact protein analysis. The nano‐LC–CZE–MS system is expected to be applicable to various other analytical challenges.

Overview

Integrity signals

Registry

Crossref · 10.1002/elps.201800411

Cites

16 of 16 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 16 references

Cited by

See all 19

Metadata

Authors
Jooß, K., Scholz, N., Meixner, J., & Neusüß, C.
Affiliations
  • Helmholtz Munich (DE)
  • Hochschule Aalen (DE)
  • Agilent Technologies (Germany) (DE)
Corresponding author
Neusüß, Christian
Venue
ELECTROPHORESIS
Publisher
Wiley
Published
2019-01-04
Volume
40
Issue
7
Pages
1061-1065
ISSN
  • 0173-0835 (ISSN-L)
  • 1522-2683
OpenAlex
W2906295627
Cited by
19
References
16
Citations by year
2026: 3 · 2025: 1 · 2023: 4 · 2022: 3 · 2021: 4 · 2020: 1 · 2019: 3
FWCI
0.80
Type
journal article
Language
en
Open access
closed
Locations
  • Electrophoresis (publishedVersion)
  • PubMed (publishedVersion)
  • OPUS (Aalen University) (submittedVersion)
  • PuSH - Publication Server of Helmholtz Zentrum München (submittedVersion)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Capillary Electrophoresis Applications
  • Physical Sciences › Chemistry › Spectroscopy › Advanced Proteomics Techniques and Applications
  • Physical Sciences › Chemistry › Spectroscopy › Mass Spectrometry Techniques and Applications
Keywords
capillary zone electrophoresis, top-down proteomics, ribonuclease B, multidimensional separation, detection limit
MeSH terms
Glycosylation, Hydrogen-Ion Concentration, Ribonucleases, Electrophoresis, Capillary, Tandem Mass Spectrometry, Chromatography, Reverse-Phase, Limit of Detection

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Heart‐cut nano‐LC–CZE–MS for the characterization of proteins on the intact level. https://app.cochat.ai/papers/10.1002/elps.201800411
The paper
Jooß, K., Scholz, N., Meixner, J., & Neusüß, C. (2019). Heart‐cut nano‐LC–CZE–MS for the characterization of proteins on the intact level. ELECTROPHORESIS. https://doi.org/10.1002/elps.201800411

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.