The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
High‐throughput capillary electrophoresis analysis of biopharmaceuticals utilizing sequential injections
Abstract
The complexity of biotherapeutic products implies an ever‐increasing list of product quality attributes that need to be monitored and characterized. In addition, the growing interest in implementing process analytical technology in biopharmaceutical production has further increased the testing burden, together with the need for rapid testing that can facilitate real‐time or near‐real‐time decision‐making. Capillary electrophoresis (CE) has made a place in biopharmaceutical analysis but is regarded as a low‐throughput method, with the instrument dead time constituting more than 80% of the total time of analysis. In this study, the dead time of CE was utilized to analyse 3 mAb samples in a single‐CE run. This approach resulted in an up to 77% reduction in the total analysis time and increased the productivity by up to 300%, compared to traditional single CE‐ultraviolet runs, without compromising resolution or relative peak areas. Additionally, good method reproducibility was observed. The compatibility of the method has been demonstrated with protein A eluate and cation exchange chromatography fractions. We, thus, propose that sequential injections can be applied for fast and robust CE analysis of biopharmaceuticals.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Capillary electrophoresis coupled with a UV detector was implemented to monitor the mAb isoforms in the eluents of CEX columns.”
From Current PAT Landscape in the Downstream Processing of Biopharmaceuticals (2025) · cites this paper as [108]
Citations
Cites
Biopharmaceutical benchmarks 2018
Walsh, G. (2018) · Nature Biotechnology · doi:10.1038/nbt.4305 · Cited by 978 · cited 1×
“Monoclonal antibodies (mAbs) presently form the bulk of biopharmaceutical pipelines [1].”
BackgroundAlt, N., Zhang, T. Y., Motchnik, P., Taticek, R., Quarmby, V., Schlothauer, T., Beck, H., Emrich, T., & Harris, R. J. (2016) · Biologicals · doi:10.1016/j.biologicals.2016.06.005 · Cited by 294
Research works printed but not linked: 22
- 10.1016/j.xphs.2019.09.023 · DOI
- 10.18869/acadpub.ibj.21.3.131 · DOI
- 10.3390/pharmaceutics13060919 · DOI
- Payne R, 2014, Continued process verification for biopharma manufacturing, BioPharm Int, 27, 48
- 10.1002/bit.26383 · DOI · Paper page
- 10.1016/j.tibtech.2020.07.004 · DOI
- 10.1016/j.tibtech.2016.01.003 · DOI
- 10.1002/elps.202100182 · DOI
- Espinosa‐De La Garza CE, 2017, Capillary electrophoresis separation of monoclonal antibody isoforms using a neutral capillary, J Visual Exp, 119
- 10.1177/1469066718807798 · DOI
- 10.1021/ac403171u · DOI
- 10.1038/s41596-020-00475-0 · DOI
- 10.1016/j.chroma.2021.462355 · DOI
- 10.1021/acs.analchem.8b05054 · DOI
- 10.3390/biomedicines9101488 · DOI
- 10.1016/j.chroma.2017.07.022 · DOI · Paper page
- 10.1002/pmic.201700310 · DOI
- 10.1016/j.jpba.2020.113218 · DOI
- 10.1039/D1AY00223F · DOI
- 10.1002/elps.201900456 · DOI
- 10.1002/elps.201600078 · DOI
- Andrasi M, 2014, Analysis of rituximab, a therapeutic monoclonal antibody by capillary zone electrophoresis, J Chromatogr Sep Tech, 6, 259
Cited by
Sorted by citations
Current PAT Landscape in the Downstream Processing of Biopharmaceuticals
Sathiyapriyan, P., Mukherjee, S., Vogel, T., Essen, L., Boerema, D., Vey, M., & Kalina, U. (2025) · Analytical Science Advances · doi:10.1002/ansa.70013 · Cited by 45
Metadata
- Authors
- Kumar, R., Sarin, D., & Rathore, A. S.
- Affiliations
- Department of Chemical Engineering Indian Institute of Technology Delhi Hauz Khas New Delhi India
- ORCID
- Rathore, Anurag S.
- Venue
- ELECTROPHORESIS
- Publisher
- Wiley
- Published
- 2023-02-08
- Volume
- 44
- Issue
- 9-10
- Pages
- 767-774
- ISSN
- 0173-0835
- 1522-2683
- Cited by
- 10
- References
- 2
- Language
- en
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: High‐throughput capillary electrophoresis analysis of biopharmaceuticals utilizing sequential injections. https://app.cochat.ai/papers/10.1002/elps.202200208
- The paper
- Kumar, R., Sarin, D., & Rathore, A. S. (2023). High‐throughput capillary electrophoresis analysis of biopharmaceuticals utilizing sequential injections. ELECTROPHORESIS. https://doi.org/10.1002/elps.202200208