Effectiveness and robustness of an asymmetric nonlinear energy sink‐inerter for dynamic response mitigation
The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
Abstract
Nonlinear energy sinks (NESs) have outperformed tuned mass dampers in mitigating undesired responses against changes in structural frequencies. However, the dilemma of gaining frequency robustness at the cost of energy sensitivity as well as the large masses of devices required for civil engineering structures impede the applications of existing NESs. To solve the issue of lacking energy robustness and take advantage of inerters to reduce physical mass, an asymmetric NES‐inerter (Asym NESI) is developed in this study. This passive inerter‐based nonlinear mass damper is configured based on an energy‐robust NES with an inerter added between the auxiliary mass and a fixed point. The paper commences with the formulation of the Asym NESI through mathematical derivations. Then an Asym NESI is designed and evaluated on a three‐story structure in comparison with other counterpart mass dampers. The effectiveness of the Asym NESI can be attributed to its unique dynamics which are revealed analytically using the harmonic balance method through free vibrations and harmonically forced vibrations. The ensuing numerical validations show that due to the integrated linear and nonlinear dynamics of the Asym NESI, the proposed device exhibits strong robustness against changes in both structural frequency and energy level. Moreover, driven by the large inertial effect induced by the auxiliary inerter, the Asym NESI shows flexibility in choosing a practical installation location without sacrificing excellent control capacity. Importantly, the benefits of the Asym NESI are further confirmed by the responses subjected to a suite of ground motions. This study provides analytical insights into the effectiveness and robustness of Asym NESIs and demonstrates substantial performance enhancement by the inerter in structural response mitigation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Synthesis of mechanical networks: the inerter
Smith, M. C. (2002) · IEEE Transactions on Automatic Control · doi:10.1109/tac.2002.803532 · Cited by 1,828
Marian, L., & Giaralis, A. (2014) · Probabilistic Engineering Mechanics · doi:10.1016/j.probengmech.2014.03.007 · Cited by 828
Using an inerter‐based device for structural vibration suppression
Lazar, I. F., Neild, S. A., & Wagg, D. J. (2014) · Earthquake Engineering & Structural Dynamics · doi:10.1002/eqe.2390 · Cited by 799
Seismic control of single‐degree‐of‐freedom structure using tuned viscous mass damper
Ikago, K., Saito, K., & Inoue, N. (2012) · Earthquake Engineering & Structural Dynamics · doi:10.1002/eqe.1138 · Cited by 782
Designs, analysis, and applications of nonlinear energy sinks
Ding, H., & Chen, L.-Q. (2020) · Nonlinear Dynamics · doi:10.1007/s11071-020-05724-1 · Cited by 553
Inducing Passive Nonlinear Energy Sinks in Vibrating Systems
Vakakis, A. F. (2001) · Journal of Vibration and Acoustics · doi:10.1115/1.1368883 · Cited by 537 · cited 1×
“Assuming that the design parameters for the Asym NESI are known, the only unknown variable left in Equations (15) and (16) is A, which can be solved by ⎧⎪⎨⎪⎪⎩ 0.”
MethodWind-Induced Vibration Mitigation in Tall Buildings Using the Tuned Mass-Damper-Inerter
Giaralis, A., & Petrini, F. (2017) · Journal of Structural Engineering · doi:10.1061/(asce)st.1943-541x.0001863 · Cited by 330
De Domenico, D., & Ricciardi, G. (2018) · Earthquake Engineering & Structural Dynamics · doi:10.1002/eqe.3098 · Cited by 302
Seismic response mitigation of a wind turbine tower using a tuned parallel inerter mass system
Zhang, R., Zhao, Z., & Dai, K. (2019) · Engineering Structures · doi:10.1016/j.engstruct.2018.11.020 · Cited by 273
Nonlinear energy sink with inerter
Zhang, Y.-W., Lu, Y.-N., Zhang, W., Teng, Y.-Y., Yang, H.-X., Yang, T.-Z., & Chen, L.-Q. (2019) · Mechanical Systems and Signal Processing · doi:10.1016/j.ymssp.2018.08.026 · Cited by 204
Cited by
A review on nonlinear energy sinks: designs, analysis and applications of impact and rotary types
Saeed, A. S., Abdul Nasar, R., & AL-Shudeifat, M. A. (2023) · Nonlinear Dynamics · doi:10.1007/s11071-022-08094-y · Cited by 208
Zhang, Y., Kong, X., Yue, C., & Xiong, H. (2021) · Nonlinear Dynamics · doi:10.1007/s11071-021-06615-9 · Cited by 70
Two-modal resonance control with an encapsulated nonlinear energy sink
Geng, X.-F., & Ding, H. (2022) · Journal of Sound and Vibration · doi:10.1016/j.jsv.2021.116667 · Cited by 64
Metadata
- Authors
- Wang, J., Wang, B., Zhang, C., & Liu, Z.
- Venue
- Earthquake Engineering & Structural Dynamics
- Publisher
- Wiley
- Published
- 2021-01-05
- Volume
- 50
- Issue
- 6
- Pages
- 1628-1650
- ISSN
- 0098-8847 (ISSN-L)
- 1096-9845
- OpenAlex
- W3119385292
- Cited by
- 51
- References
- 20
- FWCI
- 3.86
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.