The DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.
Validating the boundary element method for forward and inverse EEG computations in the presence of a hole in the skull
Open accessAbstract
Holes in the skull may have a large influence on the EEG and ERP. Inverse source modeling techniques such as dipole fitting require an accurate volume conductor model. This model should incorporate holes if present, especially when either a neuronal generator or the electrodes are close to the hole, e.g., in case of a trephine hole in the upper part of the skull. The boundary element method (BEM) is at present the preferred method for inverse computations using a realistic head model, because of its efficiency and availability. Using a simulation approach, we have studied the accuracy of the BEM by comparing it to the analytical solution for a volume conductor without a hole, and to the finite difference method (FDM) for one with a hole. Furthermore, we have evaluated the influence of holes on the results of forward and inverse computations using the BEM. Without a hole and compared to the analytical model, a three‐sphere BEM model was accurate up to 5–10%, while the corresponding FDM model had an error <0.5%. In the presence of a hole, the difference between the BEM and the FDM was, on average, 4% (1.3–11.4%). The FDM turned out to be very accurate if no hole is present. We believe that the difference between the BEM and the FDM represents the inaccuracy of the BEM. This inaccuracy in the BEM is very small compared to the effect that holes can have on the scalp potential (up to 450%). In regard to the large influence of holes on forward and inverse computations, we conclude that holes in the skull can be treated reliably by means of the BEM and should be incorporated in forward and inverse modeling. Hum. Brain Mapping 17:179–192, 2002. © 2002 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Gabriel, S., Lau, R. W., & Gabriel, C. (1996) · Physics in Medicine and Biology · doi:10.1088/0031-9155/41/11/002 · Cited by 4,270
Pascual-Marqui, R. D., Michel, C. M., & Lehmann, D. (1994) · International Journal of Psychophysiology · doi:10.1016/0167-8760(84)90014-x · Cited by 2,869
Geddes, L. A., & Baker, L. E. (1967) · Medical & Biological Engineering · doi:10.1007/bf02474537 · Cited by 1,610
Realistic conductivity geometry model of the human head for interpretation of neuromagnetic data
Hamalainen, M. S., & Sarvas, J. (1989) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.16463 · Cited by 989
Evoked dipole source potentials of the human auditory cortex
Scherg, M., & Von Cramon, D. (1986) · Electroencephalography and Clinical Neurophysiology/Evoked Potentials Section · doi:10.1016/0168-5597(86)90014-6 · Cited by 707
Two bilateral sources of the late AEP as identified by a spatio-temporal dipole model
Scherg, M., & Von Cramon, D. (1985) · Electroencephalography and Clinical Neurophysiology/Evoked Potentials Section · doi:10.1016/0168-5597(85)90033-4 · Cited by 683
Sparse Matrices in MATLAB: Design and Implementation
Gilbert, J. R., Moler, C., & Schreiber, R. (1992) · SIAM Journal on Matrix Analysis and Applications · doi:10.1137/0613024 · Cited by 591
The conductivity of the human skull: results of in vivo and in vitro measurements
Oostendorp, T. F., Delbeke, J., & Stegeman, D. F. (2000) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2000.880100 · Cited by 467
Self-citationA study of dipole localization accuracy for MEG and EEG using a human skull phantom
Leahy, R. M., Mosher, J. C., Spencer, M. E., Huang, M. X., & Lewine, J. D. (1998) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/s0013-4694(98)00057-1 · Cited by 383
Volume conduction effects in EEG and MEG
van den Broek, S. P., Reinders, F., Donderwinkel, M., & Peters, M. J. (1998) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/s0013-4694(97)00147-8 · Cited by 355
Location of Sources of Evoked Scalp Potentials: Corrections for Skull and Scalp Thicknesses
Ary, J. P., Klein, S. A., & Fender, D. H. (1981) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1981.324817 · Cited by 320
On the numerical accuracy of the boundary element method (EEG application)
Meijs, J. W. H., Weier, O. W., Peters, M. J., & Van Oosterom, A. (1989) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.40805 · Cited by 305
An improved boundary element method for realistic volume-conductor modeling
Fuchs, M., Drenckhahn, R., Wischmann, H., & Wagner, M. (1998) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.704867 · Cited by 299
Evaluation of Methods for Three-Dimensional Localization of Electrical Sources in the Human Brain
Kavanagk, R. N., Darcey, T. M., Lehmann, D., & Fender, D. H. (1978) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1978.326339 · Cited by 276
Comparison of the magnetoencephalogram and electroencephalogram
Neil Cuffin, B., & Cohen, D. (1979) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(79)90215-3 · Cited by 274
The Application of Electromagnetic Theory to Electrocardiology
Barnard, A. C. L., Duck, I. M., Lynn, M. S., & Timlake, W. P. (1967) · Biophysical Journal · doi:10.1016/s0006-3495(67)86599-8 · Cited by 256
A fast method for forward computation of multiple-shell spherical head models
Berg, P., & Scherg, M. (1994) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(94)90113-9 · Cited by 230
Source parameter estimation in inhomogeneous volume conductors of arbitrary shape
Oostendorp, T. F., & van Oosterom, A. (1989) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.19859 · Cited by 226
Self-citationThickness and resistivity variations over the upper surface of the human skull
Law, S. K. (1993) · Brain Topography · doi:10.1007/bf01191074 · Cited by 208
de Munck, J. C. (1992) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.256433 · Cited by 193
Boundary element method volume conductor models for EEG source reconstruction
Fuchs, M., Wagner, M., & Kastner, J. (2001) · Clinical Neurophysiology · doi:10.1016/s1388-2457(01)00589-2 · Cited by 165
Effects of local variations in skull and scalp thickness on EEG's and MEG's
Cuffin, B. N. (1993) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.204770 · Cited by 122
Dipole location errors in electroencephalogram source analysis due to volume conductor model errors
Vanrumste, B., Hoey, G. V., Rik Van De Walle, B., D’Havé, M., Lemahieu, I. A., & Boon, P. (2000) · Medical & Biological Engineering & Computing · doi:10.1007/bf02345748 · Cited by 91
Dipole localization in patients with epilepsy using the relistically shaped head model
Roth, B. J., Ko, D., von Albertini-Carletti, I., Scaffidi, D., & Sato, S. (1997) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/s0013-4694(96)95111-5 · Cited by 80
Improved forward EEG calculations using local mesh refinement of realistic head geometries
Yvert, B., Bertrand, O., Echallier, J. F., & Pernier, J. (1995) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(95)00120-n · Cited by 51
Yvert, B., Bertrand, O., Echallier, J. F., & Pernier, J. (1996) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0921-884x(96)95691-x · Cited by 46
Cited by
Frontal midline EEG dynamics during working memory
Onton, J., Delorme, A., & Makeig, S. (2005) · NeuroImage · doi:10.1016/j.neuroimage.2005.04.014 · Cited by 850
Electrocortical activity is coupled to gait cycle phase during treadmill walking
Gwin, J. T., Gramann, K., Makeig, S., & Ferris, D. P. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2010.08.066 · Cited by 479
Resting oscillatory cortico-subthalamic connectivity in patients with Parkinson’s disease
Litvak, V., Jha, A., Eusebio, A., Oostenveld, R., Foltynie, T., Limousin, P., Zrinzo, L., Hariz, M. I., Friston, K., & Brown, P. (2011) · Brain · doi:10.1093/brain/awq332 · Cited by 439
Self-citationOddo, C. M., Raspopovic, S., Artoni, F., Mazzoni, A., Spigler, G., Petrini, F., Giambattistelli, F., Vecchio, F., Miraglia, F., Zollo, L., et al. (2016) · eLife · doi:10.7554/elife.09148 · Cited by 332
A guideline for head volume conductor modeling in EEG and MEG
Vorwerk, J., Cho, J.-H., Rampp, S., Hamer, H., Knösche, T. R., & Wolters, C. H. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2014.06.040 · Cited by 302
Metadata
- Authors
- Oostenveld, R., & Oostendorp, T. F.
- Venue
- Human Brain Mapping
- Publisher
- Wiley
- Published
- 2002-09-25
- Volume
- 17
- Issue
- 3
- Pages
- 179-192
- ISSN
- 1065-9471 (ISSN-L)
- 1097-0193
- OpenAlex
- W2032146992
- Cited by
- 368
- References
- 26
- FWCI
- 1.77
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.