Mapping reliability in multicenter MRI: Voxel‐based morphometry and cortical thickness
Open accessThe DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
Multicenter structural MRI studies can have greater statistical power than single‐center studies. However, across‐center differences in contrast sensitivity, spatial uniformity, etc., may lead to tissue classification or image registration differences that could reduce or wholly offset the enhanced statistical power of multicenter data. Prior work has validated volumetric multicenter MRI, but robust methods for assessing reliability and power of multisite analyses with voxel‐based morphometry (VBM) and cortical thickness measurement (CORT) are not yet available. We developed quantitative methods to investigate the reproducibility of VBM and CORT to detect group differences and estimate heritability when MRI scans from different scanners running different acquisition protocols in a multicenter setup are included. The method produces brain maps displaying information such as lowest detectable effect size (or heritability) and effective number of subjects in the multicenter study. We applied the method to a five‐site multicenter calibration study using scanners from four different manufacturers, running different acquisition protocols. The reliability maps showed an overall good comparability between the sites, providing a reasonable gain in sensitivity in most parts of the brain. In large parts of the cerebrum and cortex scan pooling improved heritability estimates, with “effective‐N” values upto the theoretical maximum. For some areas, “optimal‐pool” maps indicated that leaving out a site would give better results. The reliability maps also reveal which brain regions are in any case difficult to measure reliably (e.g., around the thalamus). These tools will facilitate the design and analysis of multisite VBM and CORT studies for detecting group differences and estimating heritability. Hum Brain Mapp, 2010. © 2010 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Intraclass correlations: Uses in assessing rater reliability.
Shrout, P. E., & Fleiss, J. L. (1979) · Psychological Bulletin · doi:10.1037/0033-2909.86.2.420 · Cited by 24,532
A nonparametric method for automatic correction of intensity nonuniformity in MRI data
Sled, J. G., Zijdenbos, A. P., & Evans, A. C. (1998) · IEEE Transactions on Medical Imaging · doi:10.1109/42.668698 · Cited by 4,731 · cited 2×
“algorithm was used to correct the images for scanner RFfield nonuniformity (Sled et al., 1998).”
MethodSelf-citationMultimodality image registration by maximization of mutual information
Maes, F., Collignon, A., Vandermeulen, D., Marchal, G., & Suetens, P. (1997) · IEEE Transactions on Medical Imaging · doi:10.1109/42.563664 · Cited by 4,547 · cited 1×
“In this linear step, a joint entropy mutual information metric was optimized (Maes et al. 1997).”
MethodMethodology for Genetic Studies of Twins and Families
Neale, M. C., & Cardon, L. R. (1992) · doi:10.1007/978-94-015-8018-2 · Cited by 4,005
Han, X., Jovicich, J., Salat, D., van der Kouwe, A., Quinn, B., Czanner, S., Busa, E., Pacheco, J., Albert, M., Killiany, R., et al. (2006) · NeuroImage · doi:10.1016/j.neuroimage.2006.02.051 · Cited by 1,508
WONDERLICK, J., ZIEGLER, D., HOSSEINIVARNAMKHASTI, P., LOCASCIO, J., BAKKOUR, A., VANDERKOUWE, A., TRIANTAFYLLOU, C., CORKIN, S., & DICKERSON, B. (2009) · NeuroImage · doi:10.1016/j.neuroimage.2008.10.037 · Cited by 221 · cited 2×
“Han et al. (2006) calculated cortical thickness measurement variability maps for different acquistion protocols, but did not convert this information to ‘‘power maps,’’ while Wonderlick et al. (2009) went one step further and reported CORT ICC maps for different acquisition sequences.”
Background
Cited by
The ENIGMA Consortium: large-scale collaborative analyses of neuroimaging and genetic data
the Alzheimer’s Disease Neuroimaging Initiative, E. C., Thompson, P. M., Stein, J. L., Medland, S. E., Hibar, D. P., Vasquez, A. A., Renteria, M. E., Toro, R., Jahanshad, N., Schumann, G., et al. (2014) · Brain Imaging and Behavior · doi:10.1007/s11682-013-9269-5 · Cited by 838
“Cortical thickness and other local gray matter density measures can show reduced reliability owing to sensitivity to image contrast variability, which becomes particularly challenging in multicenter studies (Schnack et al. 2010).”
Self-citationBest practices in data analysis and sharing in neuroimaging using MRI
Nichols, T. E., Das, S., Eickhoff, S. B., Evans, A. C., Glatard, T., Hanke, M., Kriegeskorte, N., Milham, M. P., Poldrack, R. A., Poline, J.-B., et al. (2017) · Nature Neuroscience · doi:10.1038/nn.4500 · Cited by 714
Self-citationChanges in Cortical Thickness During the Course of Illness in Schizophrenia
van Haren, N. E. M. (2011) · Archives of General Psychiatry · doi:10.1001/archgenpsychiatry.2011.88 · Cited by 378
Self-citationAccelerated Brain Aging in Schizophrenia: A Longitudinal Pattern Recognition Study
Schnack, H. G., van Haren, N. E. M., Nieuwenhuis, M., Hulshoff Pol, H. E., Cahn, W., & Kahn, R. S. (2016) · American Journal of Psychiatry · doi:10.1176/appi.ajp.2015.15070922 · Cited by 374
Self-citationNieuwenhuis, M., van Haren, N. E. M., Hulshoff Pol, H. E., Cahn, W., Kahn, R. S., & Schnack, H. G. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2012.03.079 · Cited by 190
“While recent work demonstrated the possibility to combine multicenter VBM data for statistical analyses (Schnack et al., 2010), this replication study using different scanners is a first promising step in the direction of cross-site classification of individuals.”
BackgroundSelf-citation
Metadata
- Authors
- Schnack, H. G., van Haren, N. E. M., Brouwer, R. M., van Baal, G. C. M., Picchioni, M., Weisbrod, M., Sauer, H., Cannon, T. D., Huttunen, M., Lepage, C., Collins, D. L., Evans, A., Murray, R. M., Kahn, R. S., & Hulshoff Pol, H. E.
- Venue
- Human Brain Mapping
- Publisher
- Wiley
- Published
- 2010-11-16
- Volume
- 31
- Issue
- 12
- Pages
- 1967-1982
- ISSN
- 1065-9471 (ISSN-L)
- 1097-0193
- OpenAlex
- W2011334778
- Cited by
- 82
- References
- 6
- FWCI
- 3.62
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Mapping reliability in multicenter MRI: Voxel‐based morphometry and cortical thickness. https://app.cochat.ai/papers/10.1002/hbm.20991
- The paper
- Schnack, H. G., van Haren, N. E. M., Brouwer, R. M., van Baal, G. C. M., Picchioni, M., Weisbrod, M., Sauer, H., Cannon, T. D., Huttunen, M., Lepage, C., Collins, D. L., Evans, A., Murray, R. M., Kahn, R. S., & Hulshoff Pol, H. E. (2010). Mapping reliability in multicenter MRI: Voxel‐based morphometry and cortical thickness. Human Brain Mapping. https://doi.org/10.1002/hbm.20991
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.