The DOI matches its Crossref record; 46 of the 46 references it cites were found in a registry or an index.
Modeling of the human skull in EEG source analysis
Open accessAbstract
We used computer simulations to investigate finite element models of the layered structure of the human skull in EEG source analysis. Local models, where each skull location was modeled differently, and global models, where the skull was assumed to be homogeneous, were compared to a reference model, in which spongy and compact bone were explicitly accounted for. In both cases, isotropic and anisotropic conductivity assumptions were taken into account. We considered sources in the entire brain and determined errors both in the forward calculation and the reconstructed dipole position. Our results show that accounting for the local variations over the skull surface is important, whereas assuming isotropic or anisotropic skull conductivity has little influence. Moreover, we showed that, if using an isotropic and homogeneous skull model, the ratio between skin/brain and skull conductivities should be considerably lower than the commonly used 80:1. For skull modeling, we recommend (1) Local models: if compact and spongy bone can be identified with sufficient accuracy (e.g., from MRI) and their conductivities can be assumed to be known (e.g., from measurements), one should model these explicitly by assigning each voxel to one of the two conductivities, (2) Global models: if the conditions of (1) are not met, one should model the skull as either homogeneous and isotropic, but with considerably higher skull conductivity than the usual 0.0042 S/m, or as homogeneous and anisotropic, but with higher radial skull conductivity than the usual 0.0042 S/m and a considerably lower radial:tangential conductivity anisotropy than the usual 1:10. Hum Brain Mapp, 2010. © 2010 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Advances in functional and structural MR image analysis and implementation as FSL
Smith, S. M., Jenkinson, M., Woolrich, M. W., Beckmann, C. F., Behrens, T. E. J., Johansen-Berg, H., Bannister, P. R., De Luca, M., Drobnjak, I., Flitney, D. E., et al. (2004) · NeuroImage · doi:10.1016/j.neuroimage.2004.07.051 · Cited by 13,630
Hämäläinen, M., Hari, R., Ilmoniemi, R. J., Knuutila, J., & Lounasmaa, O. V. (1993) · Reviews of Modern Physics · doi:10.1103/revmodphys.65.413 · Cited by 4,684
Basic mathematical and electromagnetic concepts of the biomagnetic inverse problem
Sarvas, J. (1987) · Physics in Medicine and Biology · doi:10.1088/0031-9155/32/1/004 · Cited by 1,843
Finite Elements: Theory, Fast Solvers, and Applications in Solid Mechanics
Braess, D. (1999) · doi:10.1109/mcse.1999.10004 · Cited by 890
Finite Elements: Theory, Fast Solvers, and Applications in Solid Mechanics
Braess, D. (2007) · Cambridge University Press eBooks · doi:10.1017/cbo9780511618635 · Cited by 580
Current Distribution in the Brain From Surface Electrodes
RUSH, S., & DRISCOLL, D. A. (1968) · Anesthesia & Analgesia · doi:10.1213/00000539-196811000-00016 · Cited by 521
The conductivity of the human skull: results of in vivo and in vitro measurements
Oostendorp, T. F., Delbeke, J., & Stegeman, D. F. (2000) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2000.880100 · Cited by 467
Wolters, C. H., Anwander, A., Tricoche, X., Weinstein, D., Koch, M. A., & MacLeod, R. S. (2006) · NeuroImage · doi:10.1016/j.neuroimage.2005.10.014 · Cited by 452
Self-citationA common formalism for the Integral formulations of the forward EEG problem
Kybic, J., Clerc, M., Abboud, T., Faugeras, O., Keriven, R., & Papadopoulo, T. (2005) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2004.837363 · Cited by 422
Murakami, S., & Okada, Y. (2006) · The Journal of Physiology · doi:10.1113/jphysiol.2006.105379 · Cited by 395
Lohmann, G., Müller, K., Bosch, V., Mentzel, H., Hessler, S., Chen, L., Zysset, S., & von Cramon, D. Y. (2001) · Computerized Medical Imaging and Graphics · doi:10.1016/s0895-6111(01)00008-8 · Cited by 363
Volume conduction effects in EEG and MEG
van den Broek, S. P., Reinders, F., Donderwinkel, M., & Peters, M. J. (1998) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/s0013-4694(97)00147-8 · Cited by 355
On the numerical accuracy of the boundary element method (EEG application)
Meijs, J. W. H., Weier, O. W., Peters, M. J., & Van Oosterom, A. (1989) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.40805 · Cited by 305
Demonstration of useful differences between magnetoencephalogram and electroencephalogram
Cohen, D., & Cuffin, B. N. (1983) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(83)90005-6 · Cited by 300
Dielectric properties of mammalian tissues from 0.1 to 100 MHz; a summary of recent data
Stoy, R. D., Foster, K. R., & Schwan, H. P. (1982) · Physics in Medicine & Biology · doi:10.1088/0031-9155/27/4/002 · Cited by 248
Conductivities of Three-Layer Live Human Skull
Akhtari, M., Bryant, H. C., Mamelak, A. N., Flynn, E. R., Heller, L., Shih, J. J., Mandelkem, M., Matlachov, A., Ranken, D. M., Best, E. D., et al. (2002) · Brain Topography · doi:10.1023/a:1014590923185 · Cited by 240
The Influence of Brain Tissue Anisotropy on Human EEG and MEG
Haueisen, J., Tuch, D. S., Ramon, C., Schimpf, P. H., Wedeen, V. J., George, J. S., & Belliveau, J. W. (2002) · NeuroImage · doi:10.1006/nimg.2001.0962 · Cited by 228
Goncalves, S. I., de Munck, J. C., Verbunt, J. P. A., Bijma, F., Heethaar, R. M., & Lopes da Silva, F. (2003) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2003.812164 · Cited by 219
Lai, Y., van Drongelen, W., Ding, L., Hecox, K. E., Towle, V. L., Frim, D. M., & He, B. (2005) · Clinical Neurophysiology · doi:10.1016/j.clinph.2004.08.017 · Cited by 215
Thickness and resistivity variations over the upper surface of the human skull
Law, S. K. (1993) · Brain Topography · doi:10.1007/bf01191074 · Cited by 208
Inverse localization of electric dipole current sources in finite element models of the human head
Buchner, H., Knoll, G., Fuchs, M., Rienäcker, A., Beckmann, R., Wagner, M., Silny, J., & Pesch, J. (1997) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/s0013-4694(96)95698-9 · Cited by 180
Measurement of the Conductivity of Skull, Temporarily Removed During Epilepsy Surgery
Hoekema, R., Wieneke, G. H., Leijten, F. S. S., van Veelen, C. W. M., van Rijen, P. C., Huiskamp, G. J. M., Ansems, J., & van Huffelen, A. C. (2003) · Brain Topography · doi:10.1023/a:1025606415858 · Cited by 179
Influence of head models on EEG simulations and inverse source localizations
Ramon, C., Schimpf, P. H., & Haueisen, J. (2006) · BioMedical Engineering OnLine · doi:10.1186/1475-925x-5-10 · Cited by 179
Marin, G., Guerin, C., Baillet, S., Garnero, L., & Meunier, G. (1998) · Human Brain Mapping · doi:10.1002/(sici)1097-0193(1998)6:4<250::aid-hbm5>3.0.co;2-2 · Cited by 168
RULLMANN, M., ANWANDER, A., DANNHAUER, M., WARFIELD, S., DUFFY, F., & WOLTERS, C. (2009) · NeuroImage · doi:10.1016/j.neuroimage.2008.09.009 · Cited by 161
Self-citationDipole models for the EEG and MEG
Schimpf, P. H., Ramon, C., & Haueisen, J. (2002) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.995679 · Cited by 156
Wolters, C. H., Grasedyck, L., & Hackbusch, W. (2004) · Inverse Problems · doi:10.1088/0266-5611/20/4/007 · Cited by 153
Self-citationEffects of head shape on EEGs and MEGs
Cuffin, B. N. (1990) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.43614 · Cited by 153
Estimation of in vivo brain-to-skull conductivity ratio in humans
Zhang, Y., van Drongelen, W., & He, B. (2006) · Applied Physics Letters · doi:10.1063/1.2398883 · Cited by 145
Lead-field Bases for Electroencephalography Source Imaging
Weinstein, D. M., Евгеньевич, Ж. Л., & Johnson, C. (2000) · Annals of Biomedical Engineering · doi:10.1114/1.1310220 · Cited by 132
Sensitivity of EEG and MEG measurements to tissue conductivity
Gençer, N. G., & Acar, C. E. (2004) · Physics in Medicine and Biology · doi:10.1088/0031-9155/49/5/004 · Cited by 128
Buchner, H., Adams, L., Müller, A., et al. (1995) · Electroencephalography and Clinical Neurophysiology/Evoked Potentials Section · doi:10.1016/0168-5597(94)00228-7 · Cited by 122
Development of Volume Conductor and Source Models to Localize Epileptic Foci
Fuchs, M., Wagner, M., & Kastner, J. (2007) · Journal of Clinical Neurophysiology · doi:10.1097/wnp.0b013e318038fb3e · Cited by 111
Wolters, C. H., Köstler, H., Möller, C., Härdtlein, J., Grasedyck, L., & Hackbusch, W. (2007) · SIAM Journal on Scientific Computing · doi:10.1137/060659053 · Cited by 104
Self-citationComputational aspects of finite element modeling in EEG source localization
Awada, K. A., Jackson, D. R., Williams, J. T., Wilton, D. R., Baumann, S. B., & Papanicolaou, A. C. (1997) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.605431 · Cited by 101
Wolters, C. H., Anwander, A., Berti, G., & Hartmann, U. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2007.890736 · Cited by 98
Self-citationLew, S., Wolters, C. H., Dierkes, T., Röer, C., & MacLeod, R. (2009) · Applied Numerical Mathematics · doi:10.1016/j.apnum.2009.02.006 · Cited by 92
Self-citationModeling Skull Electrical Properties
Sadleir, R., & Argibay, A. (2007) · Annals of Biomedical Engineering · doi:10.1007/s10439-007-9343-5 · Cited by 88
Chauveau, N., Franceries, X., Doyon, B., Rigaud, B., Morucci, J. P., & Celsis, P. (2003) · Human Brain Mapping · doi:10.1002/hbm.10152 · Cited by 72
ASA-Advanced Source Analysis of Continuous and Event-Related EEG/MEG Signals
Zanow, F., & Knösche, T. R. (2004) · Brain Topography · doi:10.1023/b:brat.0000032867.41555.d0 · Cited by 71
Self-citationDrechsler, F., Wolters, C. H., Dierkes, T., Si, H., & Grasedyck, L. (2009) · NeuroImage · doi:10.1016/j.neuroimage.2009.02.024 · Cited by 71
Self-citationHallez, H., Vanrumste, B., Hese, P. V., Delputte, S., & Lemahieu, I. A. (2008) · Physics in Medicine and Biology · doi:10.1088/0031-9155/53/7/005 · Cited by 66
Lew, S., Wolters, C. H., Anwander, A., Makeig, S., & MacLeod, R. (2008) · Human Brain Mapping · doi:10.1002/hbm.20714 · Cited by 62
Self-citationPohlmeier, R., Büchner, H., Knoll, G., Rien�cker, A., Beckmann, R., & Pesch, J. (1997) · Brain Topography · doi:10.1007/bf01190384 · Cited by 61
Influence of anisotropic conductivity on EEG source reconstruction: investigations in a rabbit model
Güllmar, D., Haueisen, J., Eiselt, M., Gießler, F., Flemming, L., Anwander, A., Knösche, T. R., Wolters, C. H., Dümpelmann, M., Tuch, D. S., et al. (2006) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.876641 · Cited by 55
Self-citationRullmann, M., Anwander, A., Dannhauer, M., et al. (2010) · Max Planck Institute for Plasma Physics · Cited by 20
Self-citation
Cited by
The steady-state visual evoked potential in vision research: A review
Norcia, A. M., Appelbaum, L. G., Ales, J. M., Cottereau, B. R., & Rossion, B. (2015) · Journal of Vision · doi:10.1167/15.6.4 · Cited by 1,234
Good practice for conducting and reporting MEG research
Gross, J., Baillet, S., Barnes, G. R., Henson, R. N., Hillebrand, A., Jensen, O., Jerbi, K., Litvak, V., Maess, B., Oostenveld, R., et al. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2012.10.001 · Cited by 738
Determinants of the electric field during transcranial direct current stimulation
Opitz, A., Paulus, W., Will, S., Antunes, A., & Thielscher, A. (2015) · NeuroImage · doi:10.1016/j.neuroimage.2015.01.033 · Cited by 690
Working memory revived in older adults by synchronizing rhythmic brain circuits
Reinhart, R. M. G., & Nguyen, J. A. (2019) · Nature Neuroscience · doi:10.1038/s41593-019-0371-x · Cited by 639
Huang, Y., Liu, A. A., Lafon, B., Friedman, D., Dayan, M., Wang, X., Bikson, M., Doyle, W. K., Devinsky, O., & Parra, L. C. (2017) · eLife · doi:10.7554/elife.18834 · Cited by 556
Metadata
- Authors
- Dannhauer, M., Lanfer, B., Wolters, C. H., & Knösche, T. R.
- Venue
- Human Brain Mapping
- Publisher
- Wiley
- Published
- 2011-08-11
- Volume
- 32
- Issue
- 9
- Pages
- 1383-1399
- ISSN
- 1065-9471 (ISSN-L)
- 1097-0193
- OpenAlex
- W2068401331
- Cited by
- 268
- References
- 46
- FWCI
- 7.78
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.