Improved hepatocyte in vitro maintenance in a culture model with woven multicompartment capillary systems: Electron microscopy studies
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Primary pig hepatocytes form a tissuelike structure in an in vitro culture model that has provision for threedimensional cell orientation, cell aggregation, decentralized cell perfusion with low metabolite gradients, integral oxygenation, and nonparenchymal cell coculture. Scanning electron microscopy (SEM) has shown that hepatocytes spontaneously form aggregates in a three-dimensional structure between and on the surface of artificial capillaries. Transmission electron microscopy (TEM) has shown that after 7 weeks of in vitro perfusion, the cell ultrastructure remains similar to that of the parenchyma in vivo. Golgi complexes, active membrane processes, reorganization of cell junctions, and bile canaliculi-like intercellular spaces were demonstrated.(Hepatology 1995; 22:546-552.)
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Role of cell shape in growth control
Folkman, J., & Moscona, A. (1978) · Nature · doi:10.1038/273345a0 · Cited by 2,422
Cited by
Bhatia, S. N., Balis, U. J., Yarmush, M. L., & Toner, M. (1999) · The FASEB Journal · doi:10.1096/fasebj.13.14.1883 · Cited by 890
“(116) have developed a capillary-based reactor with an intraluminal endothelial cell compartment and extraluminal hepatocyte seeding (i.”
BackgroundThree-dimensional cell cultures: from molecular mechanisms to clinical applications
Mueller-Klieser, W. (1997) · American Journal of Physiology-Cell Physiology · doi:10.1152/ajpcell.1997.273.4.c1109 · Cited by 537
A microfabricated array bioreactor for perfused 3D liver culture
Powers, M. J., Domansky, K., Kaazempur‐Mofrad, M. R., Kalezi, A., Capitano, A., Upadhyaya, A., Kurzawski, P., Wack, K. E., Stolz, D. B., Kamm, R., et al. (2002) · Biotechnology and Bioengineering · doi:10.1002/bit.10143 · Cited by 462
Advances in bioartificial liver devices
Allen, J. W., Hassanein, T., & Bhatia, S. N. (2001) · Hepatology · doi:10.1053/jhep.2001.26753 · Cited by 326
Multicellular spheroids: a three‐dimensional in vitro culture system to study tumour biology
KUNZ‐SCHUGHART, L. A., KREUTZ, M., & KNUECHEL, R. (1998) · International Journal of Experimental Pathology · doi:10.1046/j.1365-2613.1998.00051.x · Cited by 324
Metadata
- Authors
- Gerlach, J. C., Schnoy, N., Encke, J., Smith, M. D., Müller, C., & Neuhaus, P.
- Venue
- Hepatology
- Published
- 1995-08
- Volume
- 22
- Issue
- 2
- Pages
- 546-552
- ISSN
- 0270-9139 (ISSN-L)
- OpenAlex
- W2117730155
- Cited by
- 106
- References
- 1
- FWCI
- 6.65
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Improved hepatocyte in vitro maintenance in a culture model with woven multicompartment capillary systems: Electron microscopy studies. https://app.cochat.ai/papers/10.1002/hep.1840220226
- The paper
- Gerlach, J. C., Schnoy, N., Encke, J., Smith, M. D., Müller, C., & Neuhaus, P. (1995). Improved hepatocyte in vitro maintenance in a culture model with woven multicompartment capillary systems: Electron microscopy studies. Hepatology. https://doi.org/10.1002/hep.1840220226
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.