Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 375

The DOI matches its Crossref record; 53 of the 53 references it cites were found in a registry or an index.

Optimal threshold of controlled attenuation parameter with MRI‐PDFF as the gold standard for the detection of hepatic steatosis

Open access
Caussy, Cyrielle, Alquiraish, Mosab H., Nguyen, Phirum, Hernandez, Carolyn, Cepin, Sandra, Fortney, Lynda E., Ajmera, Veeral, Bettencourt, Ricki, Collier, Summer, Hooker, Jonathan, Sy, Ethan, Rizo, Emily, Richards, Lisa, Sirlin, Claude B., Loomba, Rohit·2018·Hepatology

Abstract

The optimal threshold of controlled attenuation parameter (CAP) for the detection of hepatic steatosis using both M and XL probe is unknown in nonalcoholic fatty liver disease (NAFLD). Magnetic resonance imaging proton density fat fraction (MRI‐PDFF) is an accurate and precise method of detecting the presence of hepatic steatosis that is superior to CAP. Thus, the aim of this study was to evaluate the diagnostic accuracy and optimal threshold of CAP for the detection of hepatic steatosis as defined by MRI‐PDFF ≥ 5%. This prospective cross‐sectional study included 119 adults (59% women) with and without NAFLD who underwent MRI‐PDFF and CAP using either M or XL probe when indicated within a 6‐month period at the NAFLD Research Center, University of California, San Diego. The mean ( ± standard deviation) age and body mass index were 52.4 (±15.2) years and 29.9 (±5.5) kg/m 2 , respectively. The prevalence of NAFLD (MRI‐PDFF ≥ 5%) and MRI‐PDFF ≥ 10% was 70.6% and 47.1%, respectively. The area under the receiver operating characteristic (AUROC) of CAP for the detection of MRI‐PDFF ≥ 5% was 0.80 (95% confidence interval [CI], 0.70‐0.90) at the cut‐point of 288 dB/m and of MRI‐PDFF ≥ 10% was 0.87 (95% CI, 0.80‐0.94) at the cut‐point of 306 dB/m. When stratified by the interquartile range (IQR) of CAP, we observed that an IQR below the median (30 dB/m) had a robust AUROC compared with an IQR above the median (0.92 [95% CI, 0.85‐1.00] versus 0.70 [95% CI, 0.56‐0.85]; P = 0.0117), and these differences were statistically and clinically significant. Conclusion : The cut‐point of CAP for presence of hepatic steatosis (MRI‐PDFF ≥ 5%) was 288 dB/m. The diagnostic accuracy of CAP for the detection of hepatic steatosis is more reliable when the IQR of CAP is <30 dB/m. These data have implications for the clinical use of CAP in the assessment of NAFLD. (H epatology 2018;67:1348‐1359)

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/hep.29639

Cites

53 of 53 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 375

Metadata

Authors
Caussy, C., Alquiraish, M. H., Nguyen, P., Hernandez, C., Cepin, S., Fortney, L. E., Ajmera, V., Bettencourt, R., Collier, S., Hooker, J., Sy, E., Rizo, E., Richards, L., Sirlin, C. B., & Loomba, R.
Venue
Hepatology
Published
2018-02-19
Volume
67
Issue
4
Pages
1348-1359
ISSN
  • 0270-9139 (ISSN-L)
  • 1527-3350
OpenAlex
W2767268548
Cited by
375
References
53
FWCI
16.88
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.