CoChat

Magnetic resonance elastography plus Fibrosis‐4 versus FibroScan–aspartate aminotransferase in detection of candidates for pharmacological treatment of NASH‐related fibrosis

Open access
Tamaki, Nobuharu, Imajo, Kento, Sharpton, Suzanne, Jung, Jinho, Kawamura, Nobuyoshi, Yoneda, Masato, Valasek, Mark A., Behling, Cynthia, Sirlin, Claude B., Nakajima, Atsushi, Loomba, Rohit · 2022 · Hepatology
Cited by 60

The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.

Abstract

Background and Aims: Patients with NAFLD with significant hepatic fibrosis (Stage ≥ 2) are at increased risk of liver‐related morbidity and are candidates for pharmacologic therapies. In this study, we compared the diagnostic accuracy of MEFIB (the combination of magnetic resonance elastography [MRE] and Fibrosis‐4 [FIB‐4]) and FAST (FibroScan–aspartate aminotransferase; combined liver stiffness measurement by vibration‐controlled transient elastography, controlled attenuation parameter, and aspartate aminotransferase) for detecting significant fibrosis. Approach and Results: This prospective cohort study included 234 consecutive patients with NAFLD who underwent liver biopsy, MRE, and FibroScan at the University of California San Diego (UCSD cohort) and an independent cohort (N = 314) from Yokohama City University, Japan. The primary outcome was diagnostic accuracy for significant fibrosis (Stage ≥ 2). The proportions of significant fibrosis in the UCSD and Yokohama cohorts were 29.5% and 66.2%, respectively. Area under the receiver operating characteristic curve (95% CI) of MEFIB (0.860 [0.81–0.91]) was significantly higher than that of FAST (0.757 [0.69–0.82]) in the UCSD cohort (p = 0.005), with consistent results in the Yokohama cohort (AUROC, 0.899 [MEFIB] versus 0.724 [FAST]; p < 0.001). When used as the rule‐in criteria (MEFIB, MRE ≥ 3.3 kPa and FIB‐4 ≥ 1.6; FAST ≥ 0.67), the positive predictive value for significant fibrosis was 91.2%–96.0% for MEFIB and 74.2%–89.2% for FAST. When used as the rule‐out criteria (MEFIB, MRE < 3.3 kPa and FIB‐4 < 1.6; FAST ≤ 0.35), the negative predictive value for significant fibrosis was 85.6%–92.8% for MEFIB and 57.8%–88.3% for FAST. Conclusions: MEFIB has higher diagnostic accuracy than FAST for significant fibrosis in NAFLD, and our results support the utility of a two‐step strategy for detecting significant fibrosis in NAFLD.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/hep.32145

Cites

7 of 7 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 7 references

Cited by

See all 60

Metadata

Authors
Tamaki, N., Imajo, K., Sharpton, S., Jung, J., Kawamura, N., Yoneda, M., Valasek, M. A., Behling, C., Sirlin, C. B., Nakajima, A., & Loomba, R.
Venue
Hepatology
Published
2021-12-15
Volume
75
Issue
3
Pages
661-672
ISSN
  • 0270-9139 (ISSN-L)
  • 1527-3350
OpenAlex
W3198718894
Cited by
60
References
7
FWCI
7.35
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Magnetic resonance elastography plus Fibrosis‐4 versus FibroScan–aspartate aminotransferase in detection of candidates for pharmacological treatment of NASH‐related fibrosis. https://app.cochat.ai/papers/10.1002/hep.32145
The paper
Tamaki, N., Imajo, K., Sharpton, S., Jung, J., Kawamura, N., Yoneda, M., Valasek, M. A., Behling, C., Sirlin, C. B., Nakajima, A., & Loomba, R. (2022). Magnetic resonance elastography plus Fibrosis‐4 versus FibroScan–aspartate aminotransferase in detection of candidates for pharmacological treatment of NASH‐related fibrosis. Hepatology. https://doi.org/10.1002/hep.32145

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.