The Synthesis Rates of Total Liver Protein and Plasma Albumin Determined Simultaneously In Vivo In Humans
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Although the metabolism of liver–derived plasma proteins such as albumin has been extensively studied, human hepatic protein synthesis as a whole has not been well characterized, because a reproducible model for obtaining human liver tissue has not been available. In this study, the fractional synthesis rates of total liver protein and albumin in vivo were determined simultaneously in nine subjects undergoing elective laparoscopic cholecystectomy. l–[2H5]phenylalanine (45 mg/kg body wt) was administered for 10 minutes intravenously. Blood samples were collected at regular intervals for 90 minutes and a liver biopsy specimen was taken at 35 ± 7 minutes. The enrichments of plasma free phenylalanine, plasma albumin, and total liver protein were measured with gas chromatography mass spectrometry (GC–MS). The fractional synthesis rate (FSR) of total liver protein was 24.7 ± 3.1 %/d (mean ± SD), and that of albumin was 5.9 ±1.2%/d. The amount of albumin synthesized per day (absolute synthesis rate, ASR) was 109 ± 21 mg/kg body wt. No correlation between FSR of total liver protein and ASR of albumin was found. It is concluded that the technique of obtaining liver tissue specimens during laparoscopic surgery may serve as a human in vivo model to study total liver protein synthesis. The fractional synthesis rate of total liver proteins (stationary and exported), equals approximately 25% of the liver protein content daily. Within the range of values of this study, the absolute synthesis rate of albumin was not correlated to the fractional synthesis rate of total liver protein.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Albumin synthesis rates in cirrhosis: Correlation with child-turcotte classification
Ballmer, P. E., Walshe, D., McNurlan, M. A., Watson, H., Brunt, P. W., & Garlic, P. J. (1993) · Hepatology · doi:10.1002/hep.1840180211 · Cited by 78
Self-citation
Cited by
Barle, H., Hammarqvist, F., Westman, B., Klaude, M., Rooyackers, O., Garlick, P. J., & Wernerman, J. (2006) · Clinical Science · doi:10.1042/cs20050222 · Cited by 59
Self-citationVerbruggen, S. C., Schierbeek, H., Coss-Bu, J., Joosten, K. F. M., Castillo, L., & van Goudoever, J. B. (2011) · Clinical Nutrition · doi:10.1016/j.clnu.2011.02.001 · Cited by 34
Zhou, B., Ren, J., Han, G., Chen, Y., A, J., Gu, G., Chen, J., Wang, G., & Li, J. (2014) · Surgical Infections · doi:10.1089/sur.2012.144 · Cited by 7
Trinh, B., Peletier, M., Simonsen, C., Plomgaard, P., Karstoft, K., Pedersen, B. K., van Hall, G., & Ellingsgaard, H. (2022) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/clinem/dgac239 · Cited by 7
Metadata
- Authors
- Barle, H., Nyberg, B., Essén, P., Andersson, K., McNurlan, M. A., Wernerman, J., & Garlick, P. J.
- Venue
- Hepatology
- Published
- 1997-01
- Volume
- 25
- Issue
- 1
- Pages
- 154-158
- ISSN
- 0270-9139 (ISSN-L)
- OpenAlex
- W1995059821
- Cited by
- 83
- References
- 1
- FWCI
- 2.02
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.