The molecular adsorbent recirculating system in posthepatectomy liver failure: Results from a prospective phase I study
Open accessThe DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
Posthepatectomy liver failure (PHLF) represents the single most important cause of postoperative mortality after major liver resection, yet no effective treatment option is available. Extracorporeal liver support devices might be helpful, but systematic studies are lacking. Accordingly, we aimed to assess the safety and feasibility of the Molecular Adsorbent Recirculating System (MARS) in patients with PHLF. Between December 2012 and May 2015, a total of 206 patients underwent major or extended hepatectomy, and 10 consecutive patients with PHLF (according to the Balzan 50:50 criteria) were enrolled into the study. MARS treatment was initiated on postoperative day 5‐7, and five to seven consecutive treatment sessions were completed for each patient. In total, 59 MARS cycles were implemented, and MARS was initiated and completed without major complications in any patient. However, 1 patient developed an immense asymptomatic hyperbilirubinemia (without encephalopathy), 1 had repeated clotting problems in the MARS filter, and 2 patients experienced access problems with the central venous line. Otherwise, no adverse events were observed. In 9 patients, the bilirubin level and international normalized ratio decreased significantly (P <0.05) during MARS treatment. The 60‐ and 90‐day mortality was 0% and 10%, respectively. Among the 9 survivors, 4 still had liver dysfunction at 90 days postoperatively. Five patients were alive 1 year postoperatively without any signs of liver dysfunction or disease recurrence.Conclusion:The use of MARS in PHLF is feasible and safe and improves liver function in patients with PHLF. In the present study, 60‐ and 90‐day mortality rates were unexpectedly low compared to a historical control group. The impact of MARS treatment on mortality in PHLF should be further evaluated in a randomized controlled clinical trial. (Hepatology Communications 2018;2:445‐454)
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Bernal, W., & Wendon, J. (2013) · New England Journal of Medicine · doi:10.1056/nejmra1208937 · Cited by 1,169
Balzan, S., Belghiti, J., Farges, O., Ogata, S., Sauvanet, A., Delefosse, D., & Durand, F. (2005) · Annals of Surgery · doi:10.1097/01.sla.0000189131.90876.9e · Cited by 1,027
Liver Regeneration after Partial Hepatectomy
Michalopoulos, G. K. (2010) · The American Journal of Pathology · doi:10.2353/ajpath.2010.090675 · Cited by 713
The ???small for size??? liver syndrome
Tucker, O. N., & Heaton, N. (2005) · Current Opinion in Critical Care · doi:10.1097/01.ccx.0000157080.11117.45 · Cited by 180
Allard, M.-A., Adam, R., Bucur, P.-O., Termos, S., Cunha, A. S., Bismuth, H., Castaing, D., & Vibert, E. (2013) · Annals of Surgery · doi:10.1097/sla.0b013e3182a64b38 · Cited by 142
Cited by
Artificial liver support systems: what is new over the last decade?
García Martínez, J. J., & Bendjelid, K. (2018) · Annals of Intensive Care · doi:10.1186/s13613-018-0453-z · Cited by 137
Current evidence on posthepatectomy liver failure: Comprehensive review
Sparrelid, E., Olthof, P. B., Dasari, B. V. M., Erdmann, J. I., Santol, J., Starlinger, P., & Gilg, S. (2022) · BJS Open · doi:10.1093/bjsopen/zrac142 · Cited by 88
Self-citationSystematic review of MARS treatment in post-hepatectomy liver failure
Sparrelid, E., Gilg, S., & van Gulik, T. M. (2020) · HPB · doi:10.1016/j.hpb.2020.03.013 · Cited by 33
Self-citationGyoeri, G. P., Pereyra, D., Braunwarth, E., Ammann, M., Jonas, P., Offensperger, F., Klinglmueller, F., Baumgartner, R., Holzer, S., Gnant, M., et al. (2019) · HepatoBiliary Surgery and Nutrition · doi:10.21037/hbsn.2019.02.01 · Cited by 20
Metadata
- Authors
- Gilg, S., Sparrelid, E., Saraste, L., Nowak, G., Wahlin, S., Strömberg, C., Lundell, L., & Isaksson, B.
- Venue
- Hepatology Communications
- Published
- 2018-03-08
- Volume
- 2
- Issue
- 4
- Pages
- 445-454
- ISSN
- 2471-254X (ISSN-L)
- OpenAlex
- W2789432822
- Cited by
- 24
- References
- 5
- FWCI
- 1.47
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The molecular adsorbent recirculating system in posthepatectomy liver failure: Results from a prospective phase I study. https://app.cochat.ai/papers/10.1002/hep4.1167
- The paper
- Gilg, S., Sparrelid, E., Saraste, L., Nowak, G., Wahlin, S., Strömberg, C., Lundell, L., & Isaksson, B. (2018). The molecular adsorbent recirculating system in posthepatectomy liver failure: Results from a prospective phase I study. Hepatology Communications. https://doi.org/10.1002/hep4.1167
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.