The DOI matches its Crossref record; 152 of the 152 references it cites were found in a registry or an index.
Recent advances in designing conductive hydrogels for flexible electronics
Open accessAbstract
Flexible electronics have emerged as an exciting research area in recent years, serving as ideal interfaces bridging biological systems and conventional electronic devices. Flexible electronics can not only collect physiological signals for human health monitoring but also enrich our daily life with multifunctional smart materials and devices. Conductive hydrogels (CHs) have become promising candidates for the fabrication of flexible electronics owing to their biocompatibility, adjustable mechanical flexibility, good conductivity, and multiple stimuli‐responsive properties. To achieve on‐demand mechanical properties such as stretchability, compressibility, and elasticity, the rational design of polymer networks via modulating chemical and physical intermolecular interactions is required. Moreover, the type of conductive components (eg, electron‐conductive materials, ions) and the incorporation method also play an important role in the conductivity of CHs. Electron‐CHs usually possess excellent conductivity, while ion‐CHs are generally transparent and can generate ion gradients within the hydrogel matrices. This mini review focuses on the recent advances in the design of CHs, introducing various design strategies for electron‐CHs and ion‐CHs employed in flexible electronics and highlighting their versatile applications such as biosensors, batteries, supercapacitors, nanogenerators, actuators, touch panels, and displays.image
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Highly stretchable and tough hydrogels
Sun, J.-Y., Zhao, X., Illeperuma, W. R. K., Chaudhuri, O., Oh, K. H., Mooney, D. J., Vlassak, J. J., & Suo, Z. (2012) · Nature · doi:10.1038/nature11409 · Cited by 5,481
Double‐Network Hydrogels with Extremely High Mechanical Strength
Gong, J. P., Katsuyama, Y., Kurokawa, T., & Osada, Y. (2003) · Advanced Materials · doi:10.1002/adma.200304907 · Cited by 4,542
Highly sensitive flexible pressure sensors with microstructured rubber dielectric layers
Mannsfeld, S. C. B., Tee, B. C.-K., Stoltenberg, R. M., Chen, C. V. H.-H., Barman, S., Muir, B. V. O., Sokolov, A. N., Reese, C., & Bao, Z. (2010) · Nature Materials · doi:10.1038/nmat2834 · Cited by 3,291
Hammock, M. L., Chortos, A., Tee, B. C. ‐., Tok, J. B. ‐., & Bao, Z. (2013) · Advanced Materials · doi:10.1002/adma.201302240 · Cited by 2,396
Yuk, H., Lu, B., & Zhao, X. (2019) · Chemical Society Reviews · doi:10.1039/c8cs00595h · Cited by 2,108
Zhao, X., Wu, H., Guo, B., Dong, R., Qiu, Y., & Ma, P. X. (2017) · Biomaterials · doi:10.1016/j.biomaterials.2017.01.011 · Cited by 1,971
Flexible Nanogenerators for Energy Harvesting and Self‐Powered Electronics
Fan, F. R., Tang, W., & Wang, Z. L. (2016) · Advanced Materials · doi:10.1002/adma.201504299 · Cited by 1,918
Stretchable, Transparent, Ionic Conductors
Keplinger, C., Sun, J.-Y., Foo, C. C., Rothemund, P., Whitesides, G. M., & Suo, Z. (2013) · Science · doi:10.1126/science.1240228 · Cited by 1,754
Lab-on-Skin: A Review of Flexible and Stretchable Electronics for Wearable Health Monitoring
Liu, Y., Pharr, M., & Salvatore, G. A. (2017) · ACS Nano · doi:10.1021/acsnano.7b04898 · Cited by 1,725
Yang, C., & Suo, Z. (2018) · Nature Reviews Materials · doi:10.1038/s41578-018-0018-7 · Cited by 1,709
Cited by
Development of Conductive Hydrogels for Fabricating Flexible Strain Sensors
Li, G., Li, C., Li, G., Yu, D., Song, Z., Wang, H., Liu, X., Liu, H., & Liu, W. (2022) · Small · doi:10.1002/smll.202101518 · Cited by 509
Highly Conducting and Stretchable Double‐Network Hydrogel for Soft Bioelectronics
Li, G., Huang, K., Deng, J., Guo, M., Cai, M., Zhang, Y., & Guo, C. F. (2022) · Advanced Materials · doi:10.1002/adma.202200261 · Cited by 443
Xu, T., Liu, K., Sheng, N., Zhang, M., Liu, W., Liu, H., Dai, L., Zhang, X., Si, C., Du, H., et al. (2022) · Energy Storage Materials · doi:10.1016/j.ensm.2022.03.013 · Cited by 430
Functional Conductive Hydrogels for Bioelectronics
Fu, F., Wang, J., Zeng, H., & Yu, J. (2020) · ACS Materials Letters · doi:10.1021/acsmaterialslett.0c00309 · Cited by 364
Self-citationCui, C., Fu, Q., Meng, L., Hao, S., Dai, R., & Yang, J. (2021) · ACS Applied Bio Materials · doi:10.1021/acsabm.0c00807 · Cited by 353
Engineering Smart Composite Hydrogels for Wearable Disease Monitoring
Li, J., Ding, Q., Wang, H., Wu, Z., Gui, X., Li, C., Hu, N., Tao, K., & Wu, J. (2023) · Nano-Micro Letters · doi:10.1007/s40820-023-01079-5 · Cited by 304
Hydrogels for Flexible Electronics
Zhang, Y., Tan, Y., Lao, J., Gao, H., & Yu, J. (2023) · ACS Nano · doi:10.1021/acsnano.3c02897 · Cited by 291
Conductive polymer based hydrogels and their application in wearable sensors: a review
Liu, D., Huyan, C., Wang, Z., Guo, Z., Zhang, X., Torun, H., Mulvihill, D., Xu, B. B., & Chen, F. (2023) · Materials Horizons · doi:10.1039/d3mh00056g · Cited by 282
Probing and Manipulating Noncovalent Interactions in Functional Polymeric Systems
Chen, J., Peng, Q., Peng, X., Zhang, H., & Zeng, H. (2022) · Chemical Reviews · doi:10.1021/acs.chemrev.2c00215 · Cited by 272
Self-citationHydrogel-Based Sensor Networks: Compositions, Properties, and Applications—A Review
Sun, X., Agate, S., Salem, K. S., Lucia, L., & Pal, L. (2021) · ACS Applied Bio Materials · doi:10.1021/acsabm.0c01011 · Cited by 264
Tissue adhesive hydrogel bioelectronics
Li, S., Cong, Y., & Fu, J. (2021) · Journal of Materials Chemistry B · doi:10.1039/d1tb00523e · Cited by 257
A Review of Conductive Hydrogel‐Based Wearable Temperature Sensors
Mo, F., Zhou, P., Lin, S., Zhong, J., & Wang, Y. (2024) · Advanced Healthcare Materials · doi:10.1002/adhm.202401503 · Cited by 187
Wei, Y., Wang, H., Ding, Q., Wu, Z., Zhang, H., Tao, K., Xie, X., & Wu, J. (2022) · Materials Horizons · doi:10.1039/d2mh00284a · Cited by 66
Metadata
- Authors
- Peng, Q., Chen, J., Wang, T., Peng, X., Liu, J., Wang, X., Wang, J., & Zeng, H.
- Venue
- InfoMat
- Publisher
- Wiley
- Published
- 2020-04-07
- Volume
- 2
- Issue
- 5
- Pages
- 843-865
- ISSN
- 2567-3165 (ISSN-L)
- OpenAlex
- W3015997808
- Cited by
- 297
- References
- 152
- FWCI
- 10.40
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.